Unlocking datasets by calibrating populations of models to data density: a study in atrial electrophysiology

Brodie Lawson, Christopher Drovandi, Nicole Cusimano, Pamela Burrage, Blanca Rodríguez, Kevin Burrage

Abstract

The understanding of complex physical or biological systems requires characterising the variability underpinning these processes. Traditional calibration of populations of models (POMs) often relies on range-based selection, which ignores the underlying data density. We present a novel methodology for calibrating POMs to the full probability distributions of measured values. Using a dataset of human atrial action potentials from patients with sinus rhythm (SR) and chronic atrial fibrillation (cAF), we demonstrate that our approach accurately captures inherent biological variability and identifies key differences in stratified data.

Introduction

In biological research, the inherent variability between individuals makes "one-size-fits-all" mathematical models inadequate. To address this, researchers use Populations of Models (POMs), where a single model structure is instantiated with various parameter sets to represent a diverse population. Historically, these models were calibrated by ensuring outputs fell within the minimum and maximum ranges of experimental data. However, this "range-based" approach fails to account for data density—where most observations cluster—and ignores correlations between biomarkers, often leading to models that over-represent extreme, statistically rare phenotypes.

Methodology

We propose a two-stage calibration pipeline to match the actual probability distributions of experimental data. First, we employ Sequential Monte Carlo (SMC) sampling to efficiently explore the parameter space and identify regions that produce high-density outputs. Second, we use a simulated annealing-type algorithm for subpopulation refinement, pruning the model population to minimize the Jensen-Shannon Distance between the model-generated distributions and the experimental data. This framework was applied to the Courtemanche–Ramirez–Nattel (CRN) model of human atrial electrophysiology, using a clinical dataset of 469 cells across 363 patients, stratified by Sinus Rhythm (SR) and Chronic Atrial Fibrillation (cAF).

Results: Capturing Biological Variability

Our density-based calibration significantly outperformed traditional range-based methods. By focusing on the distribution of seven key biomarkers—including action potential duration (APD), amplitude (APA), and resting membrane potential (RMP)—the resulting POMs more accurately reflected the physiological state of the experimental population.

Distributions of the seven biomarkers (APD90, APD50, ln(APD20), APA, RMP, dV/dt_max, and V20) showing the alignment between experimental data and calibrated model populations.

The method successfully identified the ionic remodeling characteristic of cAF, specifically the downregulation of currents like $I_{to}$, $I_{Kur}$, and $I_{CaL}$. Furthermore, the distribution-calibrated models showed superior predictive power; in simulations of $I_{Kr}$ block, they correctly predicted the restoration of healthy rhythms in 95% of the cAF population, a feat range-based models struggled to replicate.

Discussion and Conclusion

A key insight from this study is that standard parameter variation (e.g., ±30%) is often insufficient to capture the full breadth of human biological diversity; our results suggest a ±100% range is necessary. Additionally, the methodology serves as a diagnostic tool for model structure. By attempting to fit the data density, we exposed inherent biases in the CRN model, such as artificial correlations between upstroke velocity and amplitude not present in the clinical data. While computationally more intensive than rejection sampling, this approach provides a more robust and predictive framework for studying complex diseases and drug responses in heterogeneous populations.

Calibrating POMs to data density rather than simple ranges unlocks the full potential of experimental datasets, providing a more nuanced understanding of biological variability and enhancing the reliability of mathematical models in clinical and pharmacological applications.

Summary updated

Abstract

The understanding of complex physical or biological systems nearly always requires a characterisation of the variability that underpins these processes. In addition, the data used to calibrate such models may also often exhibit considerable variability. A recent approach to deal with these issues has been to calibrate populations of models (POMs), that is multiple copies of a single mathematical model but with different parameter values. To date this calibration has been limited to selecting models that produce outputs that fall within the ranges of the dataset, ignoring any trends that might be present in the data. We present here a novel and general methodology for calibrating POMs to the distributions of a set of measured values in a dataset. We demonstrate the benefits of our technique using a dataset from a cardiac atrial electrophysiology study based on the differences in atrial action potential readings between patients exhibiting sinus rhythm (SR) or chronic atrial fibrillation (cAF) and the Courtemanche--Ramirez--Nattel model for human atrial action potentials. Our approach accurately captures the variability inherent in the experimental population, and allows us to identify the differences underlying stratified data as well as the effects of drug block.
BibTeX
@inproceedings{lawson2018unlocking,
  author = {Brodie Lawson and Christopher Drovandi and Nicole Cusimano and Pamela Burrage and Blanca Rodríguez and Kevin Burrage},
  title = {{Unlocking datasets by calibrating populations of models to data density: a study in atrial electrophysiology}},
  booktitle = {Science},
  year = {2018},
  doi = {10.1126/sciadv.1701676},
}
Figure