Tractography from T1-Weighted MRI Using Segmentation-Guided and Patch-Based Diffusion Model
Abstract
Motivation: Generating tractography from diffusion MRI (dMRI) is valuable for studying brain connectivity, but is limited by its accessibility. Many existing neuroimaging datasets only include T1-weighted MRI, motivating the need for a dMRI-free approach. Goal(s): This study aims to develop an efficient, accurate method to generate tractography directly from T1-weighted MRI, enabling broader applications in both clinical and research settings. Approach: We designed a segmentation-guided, patch-based framework that focuses on anatomically relevant regions, facilitating high-fidelity Tract Orientation Map (TOM) generation. Results: Our framework achieves structural accuracy comparable to dMRI-based methods, as demonstrated by quantitative and qualitative evaluations. Impact: This study introduces a novel approach for generating tractography directly from T1-weighted MRI rapidly and accurately. This can be a useful tool to facilitate large-scale brain connectivity studies without the resource constraints associated with dMRI.
BibTeX
@inproceedings{sheng2025tractography,
author = {Dian Sheng and Junyi Wang and Guofeng Xie and Lauren J. O’Donnell and Le Zhang and Fan Zhang},
title = {{Tractography from T1-Weighted MRI Using Segmentation-Guided and Patch-Based Diffusion Model}},
booktitle = {Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition},
year = {2025},
doi = {10.58530/2025/3219},
}Ask Althea to put this paper to the test.