Towards Efficient Medical Reasoning with Minimal Fine-Tuning Data

Xinlin Zhuang, Feilong Tang, Haolin Yang, Ming Hu, Huifa Li, Haochen Xue, Yichen Li, Junjun He, Zongyuan Ge, Ying Qian, Imran Razzak

Abstract

Supervised Fine-Tuning (SFT) of Large Language Models (LLMs) for specialized domains like medicine typically relies on large-scale datasets, which are often redundant or noisy. This paper introduces the Difficulty-Influence Quadrant (DIQ), a data selection strategy that identifies high-value samples by balancing reasoning complexity with optimization utility. We demonstrate that training on as little as 1% of a dataset can match full-dataset performance, while 10% consistently surpasses it, offering significant gains in computational efficiency and model quality.

Introduction

The prevailing trend in adapting LLMs to the medical domain involves "brute-force" scaling of SFT data. However, medical datasets are frequently cluttered with low-quality or redundant examples that can degrade performance or increase training costs unnecessarily. Existing selection methods often focus solely on sample difficulty, which can inadvertently prioritize noisy outliers. Conversely, focusing only on gradient influence tends to select "easy" samples that fail to challenge the model's reasoning capabilities. The DIQ framework addresses this by finding the "sweet spot": samples that are both intellectually demanding and mathematically beneficial for model optimization.

The DIQ Framework

The authors propose a two-step process to map training samples onto a 2D Difficulty-Influence plane, ensuring that the selected data is both challenging and stable for gradient-based learning.

The DIQ workflow: Step 1 involves labeling difficulty and influence scores; Step 2 selects high-value data from the resulting distribution.

1. Difficulty Scoring

A lightweight, model-agnostic classifier (BiomedBERT) is used to score samples on a 5-point Likert scale. This score reflects the inherent knowledge and reasoning complexity of the medical prompt, distinguishing between simple recall and complex clinical synthesis.

2. Influence Scoring

To measure optimization utility, the framework calculates a "Dot" score—the inner product between a training sample's gradient and the average gradient of a small, high-quality validation set. This identifies samples that move the model parameters in a direction that benefits the overall domain. To maintain efficiency, random projections are employed to reduce gradient dimensionality, avoiding the massive overhead of traditional influence functions.

Data Partitioning and Insights

By combining these scores, data is partitioned into four quadrants. The primary focus is Quadrant 1 (Q1): High-Difficulty, High-Influence.

Quadrant analysis showing (a) the distribution of samples across difficulty and influence scores and (b) the superior reasoning quality and task accuracy of Q1 samples.

Analysis reveals a critical "tension" in data selection. Samples in Q3 (High-Difficulty, Low-Influence) often represent "noisy" or overly complex outliers that provide erratic gradient signals, leading to unstable training. In contrast, Q2 (Low-Difficulty, High-Influence) samples are stable but lack the depth to teach complex reasoning. Q1 samples provide the necessary complexity while remaining aligned with the optimization goals of the target domain, leading to the highest downstream task accuracy.

Experimental Results

The DIQ framework was evaluated across nine medical benchmarks, including standard tests (MedQA, MedMCQA) and complex clinical synthesis tasks (MedBullets, MedXpertQA).

  • Efficiency and Performance: On the FineMed dataset, fine-tuning on the top 1% of DIQ-selected data (approx. 170 samples) achieved 41.46% accuracy, outperforming the full 17k dataset baseline (38.57%). Using 10% of the data consistently outperformed all baselines, including random and perplexity-based selection.
  • Clinical Alignment: Models trained with DIQ-selected data showed improved performance in differential diagnosis (DDx), safety checks, and evidence citation, as verified by both human and LLM-based evaluations.
  • Transferability: Influence scores are remarkably robust; scores calculated using a smaller model (e.g., Qwen3-8B) effectively select data for larger models (14B, 32B) or different architectures (Llama), significantly reducing the cost of data curation for large-scale deployments.

Conclusion

The Difficulty-Influence Quadrant (DIQ) framework provides a principled and efficient approach to medical SFT. By prioritizing samples that are both difficult and influential, researchers can achieve state-of-the-art performance with a fraction of the data and computational cost. Future work will explore dynamic influence updates and the impact of validation set composition on selection stability.

Summary updated

BibTeX
@inproceedings{zhuang2026towards,
  author = {Xinlin Zhuang and Feilong Tang and Haolin Yang and Ming Hu and Huifa Li and Haochen Xue and Yichen Li and Junjun He and Zongyuan Ge and Ying Qian and Imran Razzak},
  title = {{Towards Efficient Medical Reasoning with Minimal Fine-Tuning Data}},
  booktitle = {IEEE/CVF Conference on Computer Vision and Pattern Recognition},
  year = {2026},
  url = {https://openreview.net/forum?id=UMgzniheli},
}
Figure