Abstract
Magnetic Resonance Imaging (MRI) is a cornerstone of modern diagnostics, but its acquisition speed is limited by physical constraints. To accelerate imaging, techniques such as undersampling and low-resolution acquisition are employed, which often introduce artifacts and blur. This paper presents the Task Transformer Network ($T^2Net$), an end-to-end framework designed to jointly perform MRI reconstruction and super-resolution. By leveraging a transformer-based feature-sharing mechanism between two specialized neural network branches, $T^2Net$ recovers high-fidelity, artifact-free images. Experimental results on public and clinical datasets demonstrate that $T^2Net$ significantly outperforms traditional sequential processing methods, particularly at higher upscaling factors.
Introduction
The fundamental trade-off in MRI between scan time and image quality often necessitates undersampling $k$-space data or acquiring images at lower spatial resolutions. These practices lead to aliasing artifacts and loss of high-frequency details, respectively. Traditionally, these issues are addressed as separate tasks: reconstruction to remove artifacts and super-resolution (SR) to recover detail. However, sequential processing can propagate errors and fails to exploit the inherent correlations between the two tasks. $T^2Net$ addresses these limitations by treating reconstruction and SR as a unified, synergistic process.
Methods
The $T^2Net$ architecture utilizes a dual-branch design consisting of a Reconstruction (Rec) branch and a Super-Resolution (SR) branch. Both branches employ CNN backbones based on the EDSR architecture for feature extraction. The core innovation is the Task Transformer Module ($H^{tt}$), which facilitates information exchange between the branches.
The $H^{tt}$ module operates through three primary mechanisms:
- Relevance Embedding: Measures the similarity between SR features (Query) and Rec features (Key). To ensure domain consistency, Rec features undergo a sequential upsampling/downsampling step before comparison.
- Transfer Attention: Identifies relevant anatomical structures in the Rec branch to "transfer" to the SR branch.
- Soft Attention: Synthesizes these transferred features with the original SR features to maintain sharpness and anatomical accuracy.
The entire network is optimized jointly using a weighted $\ell_1$ loss function (with empirical weights $\alpha=0.2$ and $\beta=0.8$), ensuring consistency across both low-resolution reconstructed and high-resolution super-resolved outputs.
Experimental Results
The model was evaluated on the public IXI brain dataset and a clinical dataset from 155 patients. Performance was measured under $6\times$ Cartesian acceleration for $2\times$ and $4\times$ enlargement scales.
Quantitative results indicate that $T^2Net$ consistently achieves superior performance. On the IXI dataset at $4\times$ scale, $T^2Net$ reached a Peak Signal-to-Noise Ratio (PSNR) of 28.659 dB, significantly higher than the 21.895 dB achieved by the best sequential baseline (Com-D). Furthermore, $T^2Net$ demonstrates remarkable stability as the enlargement scale increases, whereas sequential methods experience substantial performance degradation. Qualitative analysis via error maps confirms that $T^2Net$ preserves fine structures, such as cerebral cortex folds, with significantly less residual noise compared to other methods.
Conclusion
$T^2Net$ demonstrates that a unified approach to MRI reconstruction and super-resolution, powered by transformer-based feature sharing, is highly effective. By breaking the sequential bottleneck, the model produces high-fidelity images even under high acceleration factors. Future work will focus on optimizing computational complexity and exploring automated hyperparameter tuning to further enhance clinical utility.
Summary updated