TAI-GAN: Temporally and Anatomically Informed GAN for early-to-late frame conversion in dynamic cardiac PET motion correction

Xueqi Guo, Luyao Shi, Xiongchao Chen, Bo Zhou, Qiong Liu, Huidong Xie, Yi-Hwa Liu, Richard Palyo, Edward J. Miller, Albert J. Sinusas, Bruce Spottiswoode, Chi Liu, Nicha C. Dvornek

Abstract

The rapid tracer kinetics of rubidium-82 ($^{82}$Rb) and high variation of cross-frame distribution in dynamic cardiac positron emission tomography (PET) raise significant challenges for inter-frame motion correction, particularly for the early frames where conventional intensity-based image registration techniques are not applicable. Alternatively, a promising approach utilizes generative methods to handle the tracer distribution changes to assist existing registration methods. To improve frame-wise registration and parametric quantification, we propose a Temporally and Anatomically Informed Generative Adversarial Network (TAI-GAN) to transform the early frames into the late reference frame using an all-to-one mapping. Specifically, a feature-wise linear modulation layer encodes channel-wise parameters generated from temporal tracer kinetics information, and rough cardiac segmentations with local shifts serve as the anatomical information. We validated our proposed method on a clinical $^{82}$Rb PET dataset and found that our TAI-GAN can produce converted early frames with high image quality, comparable to the real reference frames. After TAI-GAN conversion, motion estimation accuracy and clinical myocardial blood flow (MBF) quantification were improved compared to using the original frames.

Introduction

Dynamic cardiac Positron Emission Tomography (PET) using tracers like Rubidium-82 ($^{82}$Rb) is a powerful tool for non-invasively diagnosing coronary artery disease. However, patient motion during multi-minute scans often introduces artifacts that degrade diagnostic quality. Correcting this motion typically requires image registration to align all dynamic frames to a single reference.

A major hurdle in this process is the drastic change in tracer distribution over time. In early frames, the tracer is concentrated in the heart's chambers (blood pool), while in late frames, it migrates into the heart muscle (myocardium). Standard registration algorithms, which rely on intensity similarity, often fail to align these structurally different "hollow" early frames to "solid" late frames. TAI-GAN addresses this by synthesizing late-stage myocardial images from early-stage blood-pool data.

Methodology

TAI-GAN employs an "all-to-one" mapping system that transforms any early frame into a synthetic version of the final reference frame. The architecture is built upon two primary innovations to ensure accuracy and structural integrity:

  1. Temporally Informed (via FiLM): The model incorporates the frame's temporal index and Time-Activity Curves (TACs) of the blood pool. These are processed by an LSTM and injected into the 3D U-Net generator using Feature-wise Linear Modulation (FiLM) layers. This allows the network to adapt its transformation based on the specific stage of tracer wash-in.
  2. Anatomically Informed: To prevent the GAN from "hallucinating" structures or shifting the heart's position, the model receives "rough segmentations" (masks of the ventricles and myocardium) as an additional input channel. These masks act as spatial anchors, keeping the heart muscle pinned to its correct anatomical location.
The TAI-GAN architecture incorporates temporal data (TACs) and anatomical masks to guide the frame conversion process.

Results and Discussion

The proposed method was validated on a clinical dataset of 85 $^{82}$Rb PET scans with simulated realistic motion. TAI-GAN outperformed vanilla GANs and MSE-based models across both image quality and clinical metrics. It achieved a Structural Similarity Index (SSIM) of 0.733, the highest among tested methods.

Quantitatively, the mean absolute motion prediction error was reduced from 4.45 mm (without conversion) to 3.48 mm using TAI-GAN. Most significantly, clinical accuracy in calculating Myocardial Blood Flow (MBF) was substantially improved. As shown in the scatter plots, TAI-GAN results align most closely with the identity line of the motion-free ground truth, demonstrating its effectiveness in restoring parametric quantification accuracy.

Quantitative comparison of motion estimation error (table) and MBF quantification accuracy (scatter plots) across different methods.

Conclusion

TAI-GAN successfully bridges the gap between early and late dynamic PET frames by integrating temporal kinetics and anatomical priors. By enabling more accurate registration, it significantly improves the precision of non-invasive MBF measurements. Future work will focus on validating the method against invasive catheterization gold standards and testing on real-world datasets with complex, non-simulated motion.

Summary updated

Abstract

The rapid tracer kinetics of rubidium-82 ($^{82}$Rb) and high variation of cross-frame distribution in dynamic cardiac positron emission tomography (PET) raise significant challenges for inter-frame motion correction, particularly for the early frames where conventional intensity-based image registration techniques are not applicable. Alternatively, a promising approach utilizes generative methods to handle the tracer distribution changes to assist existing registration methods. To improve frame-wise registration and parametric quantification, we propose a Temporally and Anatomically Informed Generative Adversarial Network (TAI-GAN) to transform the early frames into the late reference frame using an all-to-one mapping. Specifically, a feature-wise linear modulation layer encodes channel-wise parameters generated from temporal tracer kinetics information, and rough cardiac segmentations with local shifts serve as the anatomical information. We validated our proposed method on a clinical $^{82}$Rb PET dataset and found that our TAI-GAN can produce converted early frames with high image quality, comparable to the real reference frames. After TAI-GAN conversion, motion estimation accuracy and clinical myocardial blood flow (MBF) quantification were improved compared to using the original frames. Our code is published at https://github.com/gxq1998/TAI-GAN.
BibTeX
@inproceedings{guo2023tai,
  author = {Xueqi Guo and Luyao Shi and Xiongchao Chen and Bo Zhou and Qiong Liu and Huidong Xie and Yi-Hwa Liu and Richard Palyo and Edward J. Miller and Albert J. Sinusas and Bruce Spottiswoode and Chi Liu and Nicha C. Dvornek},
  title = {{TAI-GAN: Temporally and Anatomically Informed GAN for early-to-late frame conversion in dynamic cardiac PET motion correction}},
  booktitle = {SASHIMI @ MICCAI},
  year = {2023},
  doi = {10.1007/978-3-031-44689-4\_7},
}