Introduction
Training deep neural networks (DNNs) for medical image segmentation is notoriously difficult due to the scarcity of clean, pixel-level annotations. While DNNs are powerful, they are prone to the "memorization effect," where the model eventually learns and replicates errors present in noisy training labels. In medical contexts, noise is common due to boundary ambiguity and varying expertise among annotators.
Existing noise-robust learning methods typically focus on image-level weighting or pixel-level selection. Image-level methods discard valuable clean regions within noisy images, while pixel-level methods often ignore spatial correlations, leading to fragmented and anatomically inconsistent predictions. This paper proposes a novel framework that utilizes superpixels as the fundamental unit for learning and refinement, leveraging their inherent ability to preserve structural and spatial priors.
Methodology
The proposed framework employs an iterative learning strategy centered on superpixels—clusters of pixels with similar visual properties generated via the SLIC algorithm. The architecture consists of two identical networks trained in parallel to identify and correct noisy labels.
1. Noise-Aware Network Update
The system selects "clean" superpixels based on a loss function that combines classification accuracy and inter-network consensus. By operating at the superpixel level rather than the pixel level, the model naturally enforces spatial smoothness and respects object boundaries.
2. Adaptive Stopping and Label Refinement
To prevent noise memorization, the authors monitor the "loss gap" between selected and unselected superpixels, stopping training when the divergence peaks. Following this, the networks identify the most unreliable (high-loss) labels and overwrite them with consensus predictions. These refined labels are then used for the subsequent training iteration, creating a self-improving feedback loop.
Experimental Results
The method was evaluated on the ISIC 2017 (skin lesion) and JSRT (chest X-ray) datasets. Since standard benchmarks for real-world medical label noise are limited, the authors simulated noise using morphological and affine transformations, controlled by parameters $\alpha$ (corruption ratio) and $\beta$ (noise severity).
As shown in the results table, the proposed method consistently outperforms state-of-the-art baselines like Co-teaching, Tri-network, and JoCoR. Under extreme noise conditions ($\alpha=1.0, \beta=0.7$), where every image is heavily corrupted, the method maintains a high Dice score of 81.39%, significantly higher than the next best method, JoCoR, which achieved 74.30%.
Discussion and Conclusion
Ablation studies confirmed the importance of each component. Specifically, replacing superpixels with standard pixel-level selection resulted in a significant performance drop (approximately 2% in Dice score), highlighting the value of structural priors in medical imaging.
While the results are promising, the study's reliance on simulated noise is a limitation. Real-world clinical errors may be more nuanced than geometric transformations. Future research should focus on developing benchmarks with genuine human-annotated noise to further validate robust learning strategies in clinical settings.
Summary updated