NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Speech Artifact Removal from EEG Recordings of Spoken Word Production with Tensor Decomposition

Holy Lovenia, Hiroki Tanaka, Sakriani Sakti, Ayu Purwarianti, Satoshi NakamuraarXiv 2022 · DOI

TL;DR

Researchers have developed a new method using three-mode tensor decomposition to clean "noisy" EEG data recorded while people are actually speaking. By treating EEG data as a 3D structure (time x space x frequency) rather than a flat matrix, this approach significantly outperforms traditional methods in removing muscle interference while preserving delicate brain signals.

What Problem Does This Paper Address?

Studying the brain's language centers is notoriously difficult because of a fundamental conflict: to study speech, you want subjects to talk, but the act of talking creates massive electrical interference. Electroencephalogram (EEG) signals are incredibly faint, and the muscle movements from the jaw, tongue, and lips (electromyogram or EMG) act like a loud static that drowns out the cognitive processes researchers want to observe.

To avoid this, many studies use "covert speech" (thinking words without saying them), but this doesn't capture the full natural process of articulation. Existing cleanup methods like Independent Component Analysis (ICA) usually collapse data into 2D matrices, which can strip away useful brain activity along with the noise. The authors aim to provide a more surgical way to remove speech artifacts without losing the underlying neural data.

Methods

The core innovation is the move from matrix decomposition to Tensor Decomposition. While standard methods like ICA or BSS (Blind Source Separation) look at two dimensions (usually time and space), EEG data is inherently multi-dimensional.

The authors proposed a third-order Canonical Polyadic Decomposition (CPD), also known as PARAFAC. They structured the data into a tensor with three modes:

  1. Time: The brain activity over the course of a trial.
  2. Space: The 27 EEG electrode channels.
  3. Frequency: The spectral components of the signal.

![Fig.

  1. Third-order tensor with two CPD components](/figures/art_89c0d6843ab040e2885eceb858cfdc25)

By decomposing the data this way, they could identify specific "Kruskal tensors" (components) that showed high correlation with lip EMG signals in both the time and frequency domains. These components were flagged as artifacts and removed, while the remaining "clean" components were reconstructed into the final signal.

Datasets

The study involved:

  • Participants: 9 native Japanese speakers.
  • Task: A picture-naming task using 45 different line drawings of common objects.
  • Hardware: 27 EEG electrodes, 2 EOG electrodes (to monitor eye blinks), and 2 EMG electrodes placed on the lips (OOS and OOI) to serve as the ground truth for speech muscle activity.
  • Software: Analysis was performed using the FieldTrip and Tensor Toolbox for MATLAB.

Key Insights and Ideas

  • The Multi-way Advantage: EEG data is naturally "multi-way." Traditional methods often "unfold" this data into a 2D matrix, which can obscure the relationships between frequency and space. Tensor decomposition preserves these relationships, allowing for a more accurate separation of brain vs. muscle.
  • EMG as a Benchmark: By recording lip EMG simultaneously, the researchers created a "gold standard" for what the noise looks like. This allowed them to prove that their decomposed artifacts weren't just random noise—they were a near-perfect match for the physical movement of the lips.
  • Preservation of Pre-speech Signal: A critical test for any artifact removal is ensuring it doesn't "over-clean" the data. The authors validated their method by checking the correlation of data before speech onset, ensuring that the cognitive planning phases remained intact.

Key Results

The proposed Tensor Decomposition (TD/CPD) method was compared against two established baselines: SAR-ICA and BSS-CCA.

  • Artifact Detection: The CPD method's identified speech artifacts had a 0.985 correlation with the actual lip EMG, significantly higher than SAR-ICA's 0.875. This shows the method is exceptionally good at "finding" the noise.
  • Cleanliness: The correlation between the cleaned data and the lip EMG was only 0.101 for the CPD method (lower is better here), compared to 0.351 for ICA and 0.413 for BSS-CCA. This indicates the CPD method left far less residual noise in the final signal.

![Fig.

  1. Comparison of normalized grand-average lip EMG and decomposed speech artifacts](/figures/art_3b9b52d5a5124521bdf92b40b846e6d0)

As seen in the figure above, the decomposed artifacts (red line) track the actual muscle movements (blue dashed line) with remarkable precision, especially during the peak of the speech act.

Limitations and Future Work

The primary limitation noted is that the process still requires manual visual inspection to finalize which components are artifacts. While the statistical correlations provide a strong guide, a human expert still had to look at topographical distributions to make the final call.

The authors suggest that future research should focus on full automation of the identification steps. Additionally, while the lip EMG is a great proxy for speech noise, it doesn't capture every single internal muscle movement (like the tongue), suggesting that even more sophisticated multi-sensor setups could further refine the cleaning process.

Summary updated

BibTeX
@misc{lovenia2022speech,
  author = {Holy Lovenia and Hiroki Tanaka and Sakriani Sakti and Ayu Purwarianti and Satoshi Nakamura},
  title = {{Speech Artifact Removal from EEG Recordings of Spoken Word Production with Tensor Decomposition}},