SOAR: Semantic Organ-Aware Pretraining for 3D CT Image Understanding

Huidong Xie, Wei Ji, Sunan He, Zhihao Tang, tangwen, Jun Zhao, Hongming ShanNeurIPS 2026

TL;DR

Teaching AI to read 3D CT scans by pairing them with radiology reports hits a fundamental snag: a CT scan captures dozens of organs in vivid 3D detail, while a radiologist’s report only mentions the few things that look abnormal. SOAR bypasses reports entirely during pretraining, instead using off-the-shelf anatomical segmentation models to teach a 3D vision encoder what organs look like, how they fit together, and what they are called. The result is a sharper, anatomically grounded visual backbone that plugs straight into Large Language Models (LLMs) to significantly boost disease screening and medical visual question answering (VQA).

What Problem Does This Paper Address?

When building foundation models for 3D medical imaging, researchers usually lean on two classic self-supervised playbooks: Masked Autoencoders (MAE) and CLIP-style vision-language alignment. Both stumble when confronted with the unique nature of 3D CT volumes.

With MAE, you randomly mask out 3D patches of an image and ask the model to fill in the blanks. Because neighboring voxels inside an organ (say, the liver) share nearly identical textures and intensities, the model can "cheat" by copying nearby pixels—learning local interpolation rather than high-level anatomy.

With CLIP, you align an entire 3D scan with its diagnostic text report. Here, you hit a massive semantic gap. As the authors illustrate, a single chest CT volume might contain 86 distinct anatomical structures, yet the accompanying report mentions only 12 clinically salient ones. Aligning a dense 3D volume with a sparse summary leaves most of the human anatomy ungrounded and underrepresented.

Figure 1: Motivation and quantitative summary. (a) Random patch masking in MAE may rely on nearby visual context, limiting anatomical modeling. (b) Vanilla VLA aligns a 3D CT volume with a sparse report, leading to coarse-grained semantics. (c) SOAR uses organ-aware masking and organ-level VLA to promote anatomical modeling and reduce the semantic gap. (d) Radar plot comparing CLIP, MAE, and SOAR across downstream evaluations. Closed-ended VQA is measured by accuracy and disease screening and abnormality detection are measured by AUC.

Methods

Rather than inventing a complex new neural architecture, SOAR (Semantic Organ-Aware Pretraining) reorganizes how a standard 3D Vision Transformer (ViT) is trained. Its secret weapon is TotalSegmentator—an existing, automated 3D segmentation tool that labels 117 anatomical classes at the voxel level. Using these automatically generated pseudo-labels as structural anchors, SOAR pretrains the vision encoder without needing a single radiologist annotation or paired text report.

Figure 2: Overview of SOAR. SOAR uses automatically derived 3D anatomical priors to pretrain a 3D visual encoder with three organ-aware objectives. In organ-level masked reconstruction (organ-recon), patches from randomly selected organ regions are masked and reconstructed with organ-conditioned mask tokens. In organ-level vision-language alignment (organ-align), visual tokens are grouped by organ-level anatomical regions and aligned with corresponding anatomical text embeddings. In organ-level supervision (organ-super), the encoder is encouraged to preserve voxel-level anatomical organization, enabling fine-grained anatomical representation learning.

SOAR combines three complementary objectives in a staged training setup:

  1. Organ-level Masked Reconstruction: Instead of masking random scattered patches, SOAR masks out ~30 entire organs at a time. To reconstruct a missing heart or lung, the model can no longer copy adjacent textures; it must infer the organ from global anatomical context. Furthermore, instead of using a generic "blank" mask token, SOAR injects learnable organ-conditioned mask tokens weighted by how much of each organ occupies a patch.
  2. Organ-level Vision-Language Alignment: To connect visual features to language without noisy reports, SOAR groups all visual tokens belonging to a specific organ, pools them into a fixed-size vector using a learnable organ query token, and aligns them (via a CLIP-style contrastive loss) with the concise text embedding of that organ’s name generated by a frozen PubMedBERT.
  3. Organ-level Supervision: Because patch tokens compress spatial details, an auxiliary decoder is tasked with predicting the original voxel-by-voxel 3D segmentation mask (using Cross-Entropy and Dice losses), forcing the encoder to retain crisp boundary details.

Once pretrained, all the auxiliary decoders and query tokens are thrown away, leaving behind a standard 3D ViT encoder ready to be wired into an LLM (like LLaMA-3.1-8B via LoRA) or a classification head.

Datasets

No new public benchmarks are introduced, though one in-house clinical dataset is utilized.

  • Pretraining: CT-RATE (25,692 non-contrast chest CT scans reconstructed into 50,188 3D volumes).
  • VQA Evaluation: CT-RATE (>2.7M report-derived VQA pairs), 3D-RAD (170,105 chest CT QA pairs), and AMOS-MM (19,562 closed-ended abdominal CT QA pairs—testing cross-region transfer).
  • Disease & Abnormality Screening: CT-RATE multi-abnormality labels, a public CT pneumonia dataset (3,777 patients), and an in-house esophageal cancer screening dataset (2,648 chest CT studies).

Key Insights and Ideas

  • Segmentation models are untapped teachers for VLM backbones: Medical segmentation models already know where everything is. Distilling those spatial priors into a general-purpose vision encoder solves the "sparse report" problem cleanly and at scale.
  • Masking whole organs forces true anatomical reasoning: In ablation studies, simply switching from vanilla random patch masking to 30-organ masking jumped closed-ended VQA accuracy on CT-RATE from 85.76% to 88.64%—before even adding text alignment or voxel supervision.
  • Report-free pretraining transfers to report-style tasks: Remarkably, even though SOAR never sees a radiology report during pretraining, its fine-grained anatomical grounding makes downstream LLMs less prone to hallucinating findings or mislocalizing lung lobes during open-ended VQA.

Key Results

Across five benchmarks and against strong 3D baselines (MAE, CLIP, fVLM, ViSD, and VoCo), SOAR improves multiple-choice VQA accuracy by an average of 3.53 percentage points and disease screening/abnormality detection AUC by 4.25 points across all baselines and tasks.

  • Medical VQA: SOAR hits 89.87% closed-ended accuracy on CT-RATE and 75.38% overall accuracy on abdominal AMOS-MM (showing chest-pretrained anatomical awareness transfers to the abdomen). On open-ended VQA, it achieves the top GREEN score (an LLM-based clinical faithfulness metric) on CT-RATE (46.83) and 3D-RAD Anomaly Detection (35.52, beating the runner-up by +2.09).
  • Screening & Detection: SOAR sweeps first place across all tasks, reaching 97.99% average AUC on pneumonia classification, 95.89% AUC on esophageal cancer screening, and 75.38% average AUC on CT-RATE multi-abnormality detection (+1.69 over the next-best baseline).

Limitations and Future Work

In the main text, the authors explicitly defer their discussion of limitations and future directions to Appendix C (which is outside the provided 10-page main paper). However, one practical boundary noted in the methodology is that while SOAR requires zero manual annotations on the pretraining data itself, its anatomical priors inherently depend on the scope and pseudo-label quality of TotalSegmentator (fixed at 117 anatomical classes).

Summary updated

Abstract

Vision-language pretraining has advanced multimodal medical AI, but its direct application to 3D computed tomography (CT) remains limited by a fundamental mismatch between dense volumetric anatomy and sparse diagnostic reports. Existing 3D CT vision-language methods typically rely on global image-report alignment or align anatomical regions with decomposed report descriptions. However, a CT scan captures rich, spatially distributed information across many organs, whereas a report summarizes only a small subset of clinically relevant findings. As a result, report-based alignment provides incomplete or weak supervision, leaving many local anatomical structures underrepresented. Motivated by this limitation, we introduce **SOAR**, a **s**emantic **o**rgan-**a**ware p**r**etraining framework for 3D CT image understanding. The key innovation of SOAR lies in its integration of fine-grained, organ-level structural priors, enabling report-free organ-aware supervision for visual pretraining without relying on radiologist annotations or coarse global image-report matching. SOAR combines three complementary objectives: (**i**) *organ-level masked reconstruction* to learn localized anatomical context, (**ii**) *organ-level vision-language alignment* to associate organ-specific visual features with organ-name text embeddings, and (**iii**) *organ-level supervision* to preserve voxel-level structural detail. SOAR integrates easily with existing LLMs and is evaluated on five public/in-house benchmarks, improving multiple-choice VQA accuracy by 3.53 percentage points and disease screening/abnormality detection AUC by 4.25 points on average over all benchmarks/baseline methods. Code and model weights are available at https://github.com/HuidongXie/SOAR_CT.
BibTeX
@inproceedings{xie2026soar,
  author = {Huidong Xie and Wei Ji and Sunan He and Zhihao Tang and tangwen and Jun Zhao and Hongming Shan},
  title = {{SOAR: Semantic Organ-Aware Pretraining for 3D CT Image Understanding}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=xwakWJUI55},
}
Figure