SLICES: A Benchmark and Evaluation Framework for Self-Supervised Learning on Sparse ICU Time Series

Hannes Ill, Dimitrios Proios, Leo Anthony Celi, Peter J. Schüffler

TL;DR

SLICES is a new evaluation framework designed to bring order to the "Wild West" of self-supervised learning (SSL) on sparse ICU time series. By fixing the data processing, encoder architecture, and evaluation protocols, the authors show that while Masked Autoencoding (MAE) is a powerful SSL objective, classical supervised baselines like XGBoost and GRU-D remain surprisingly difficult to beat in the clinical setting.

What Problem Does This Paper Address?

Intensive Care Unit (ICU) data is notoriously difficult to work with. It is "sparse" and "irregular"—vital signs might be recorded every minute, while lab results appear only once a day. Interestingly, the absence of a measurement often carries as much clinical information as the value itself (a concept known as "informative missingness").

Self-supervised learning (SSL) is a natural fit for this domain because unlabeled ICU data is abundant, while high-quality clinical labels are expensive to produce. However, comparing different SSL methods has been nearly impossible. Researchers often vary their data preprocessing, neural architectures, and evaluation tasks simultaneously. If Method A beats Method B, is it because of the learning objective, a better encoder, or just a more favorable data split? SLICES (Self-supervised Learning on Sparse ICU Time Series) addresses this by providing a standardized "sandbox" where only the SSL objective varies.

Methods

The core philosophy of SLICES is controlled comparison. The framework fixes several key variables:

  • Input Representation: A 24-hour window of 84 clinical variables, represented as both values and observation masks (binary indicators of whether a measurement occurred).
  • Encoder: A standardized, relatively small Transformer (approx. 160k parameters).
  • Evaluation Protocols: Two distinct paths—Linear Probing (freezing the encoder and training a simple head) to test representation quality, and Full Fine-tuning to test the utility of the pretrained initialization.

The authors implement and compare three major SSL families within this framework:

  1. Masked Autoencoding (MAE): Reconstructing masked-out hourly values.
  2. Joint-Embedding Prediction (JEPA): Predicting the latent embeddings of masked blocks.
  3. Contrastive Learning: Aligning different "views" (augmentations) of the same patient stay.

Datasets

The benchmark utilizes two of the most prominent deidentified ICU databases:

  • MIMIC-IV (v3.1): ~75,000 stays.
  • eICU-CRD (v2.0): ~133,000 stays.
  • Combined: A pooled union of both datasets (~208,000 stays) to test scaling and cross-source robustness.

Key Insights and Ideas

  • MAE is the SSL "King" (for now): Among the SSL objectives, MAE consistently led in performance, particularly in frozen classification tasks. The authors hypothesize that because the input interface explicitly exposes the observation mask, reconstruction-based tasks are highly effective at capturing the underlying clinical patterns.
  • The Persistence of Baselines: One of the most sobering "aha moments" is that classical supervised models are still incredibly strong. XGBoost (using tabular summaries) led in Acute Kidney Injury (AKI) prediction, and GRU-D (a recurrent model designed for missing data) led in 24-hour mortality prediction. SSL is not a magic bullet that automatically renders specialized supervised architectures obsolete.
  • Protocol Sensitivity: A method’s ranking can change entirely depending on the evaluation protocol. A model that looks mediocre under a linear probe might suddenly leap to the top when fine-tuned. This highlights why researchers must report both to provide a complete picture.
  • Informative Missingness is Real: A simple linear model trained only on the observation masks (ignoring the actual heart rate or lab values) achieved an AUPRC of 0.301 for hospital mortality. This confirms that the "care process" (when doctors choose to order a test) is a massive signal in ICU data.

Key Results

  • Classification: MAE led mean AUPRC in all nine "frozen" classification comparisons. In fine-tuning, it led in seven of nine cases.
  • Label Efficiency: SSL shines when data is scarce. Fine-tuned MAE outperformed a supervised Transformer of the same architecture at every label fraction (from 1% to 100%) for hospital mortality.
  • Length of Stay (LOS): SSL fine-tuning achieved the lowest error for predicting remaining ICU stay, beating all supervised baselines.
  • Reproducibility: The authors performed a "rerun" of their own pipeline on MIMIC-IV and found that results stayed within two standard deviations of the original reference, proving the framework's stability.

Limitations and Future Work

The authors are transparent about what SLICES does not yet do:

  • Out-of-Domain Generalization: The current study doesn't test "zero-shot" transfer to entirely unseen hospitals with different coding practices.
  • Architecture Constraints: The framework currently mandates a Transformer encoder. Future iterations could extend this to recurrent models like GRU-D or Mamba.
  • Fixed Windows: The 24-hour input window is standard for benchmarks but doesn't capture the full longitudinal history of long-term ICU stays.

The team has released the code and auditable result aggregates, inviting the community to plug in new SSL objectives and see how they stack up against these established references.

Summary updated

Abstract

Self-supervised learning (SSL) results for intensive care unit (ICU) time series are hard to compare when data processing, encoders, and adaptation vary together. We present SLICES, a benchmark and evaluation framework for comparing and extending SSL methods under a shared clinical setup. It fixes 24-hour value and observation-mask inputs, a Transformer encoder, patient-level splits, four endpoints, two adaptation protocols, and five matched seeds across MIMIC-IV, eICU-CRD, and their pooled union. Masked autoencoding (MAE), joint-embedding prediction (JEPA), and contrastive learning provide reference implementations. Among these objectives, MAE leads mean AUPRC in all nine frozen classification comparisons, also under converged probes, and in seven of nine fine-tuning comparisons. Fine-tuned MAE leads hospital mortality at full labels and scores higher than a supervised Transformer of the same architecture at every label fraction, and SSL fine-tuning gives the lowest length-of-stay error. Supervised baselines remain strong elsewhere: GRU-D leads 24-hour mortality and XGBoost leads acute kidney injury in all three regimes. Rankings depend on the adaptation protocol, the comparator set, and whether the probe loss matches the metric. A two-seed MIMIC-IV rerun with the maintained code stays within two across-seed SDs of the reference in all 48 downstream runs. The code repository supports new objectives, shared downstream evaluation, and regeneration of the reference results, so new SSL methods can be compared with these references under the same conditions. Generalization to unseen hospitals is not tested here and is the natural next extension.
BibTeX
@misc{ill2026slices,
  author = {Hannes Ill and Dimitrios Proios and Leo Anthony Celi and Peter J. Schüffler},
  title = {{SLICES: A Benchmark and Evaluation Framework for Self-Supervised Learning on Sparse ICU Time Series}},
  year = {2026},
  eprint = {2611.18868},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.18868},
}
Figure