Skill-Evolving Grounded Reasoning for Free-Text Promptable 3D Medical Image Segmentation

Tongrui Zhang, Chenhui Wang, Yongming Li, Zhihao Chen, Xufeng Zhan, Hongming ShanarXiv 2026 · DOI

Abstract

Free-text promptable 3D medical image segmentation offers an intuitive and clinically flexible interaction paradigm. However, current methods are highly sensitive to linguistic variability: minor changes in phrasing can cause substantial performance degradation despite identical clinical intent. Existing approaches attempt to improve robustness through stronger vision-language fusion or larger vocabularies, yet they lack mechanisms to consistently align ambiguous free-form expressions with anatomically grounded representations. We propose Skill-Evolving grounded Reasoning (SEER), a novel framework for free-text promptable 3D medical image segmentation that explicitly bridges linguistic variability and anatomical precision through a reasoning-driven design. First, we curate the SEER-Trace dataset, which pairs raw clinical requests with image-grounded, skill-tagged reasoning traces, establishing a reproducible benchmark. Second, SEER constructs an evidence-aligned target representation via a vision-language reasoning chain that verifies clinical intent against image-derived anatomical evidence, thereby enforcing semantic consistency before voxel-level decoding. Third, we introduce SEER-Loop, a dynamic skill-evolving strategy that distills high-reward reasoning trajectories into reusable skill artifacts and progressively integrates them into subsequent inference, enabling structured self-refinement and improved robustness to diverse linguistic expressions. Extensive experiments demonstrate superior performance of SEER over state-of-the-art baselines. Under linguistic perturbations, SEER reduces performance variance by 81.94% and improves worst-case Dice by 18.60%.

Introduction

While 3D medical image segmentation has advanced rapidly, most models rely on predefined "label sets" (e.g., a user must click a button for "Liver"). In the real world, clinicians use unstructured language: abbreviations ("LV" for left ventricle), synonyms, or complex descriptions in radiology reports. Current "promptable" models are notoriously brittle; a minor change in phrasing—like adding "please" or a simple typo—can cause the segmentation mask to shift or fail entirely, even if the clinical intent is identical. This linguistic variability is a major barrier to deploying AI assistants in clinical workflows. SEER addresses this by moving away from direct text-to-feature mapping in favor of a reasoning-driven architecture that verifies text against visual evidence.

The SEER Framework

Overview of the SEER framework, illustrating the Grounded Reasoning chain and the SEER-Loop for skill evolution.

SEER introduces a multi-stage approach to stabilize segmentation against noisy prompts:

  1. Grounded Reasoning Chain: Instead of mapping prompts directly to masks, SEER uses a Vision-Language Model (VLM) to perform three distinct steps: Evidence Extraction (identifying observable anatomical cues), Rationale Formulation (linking ambiguous text to visual evidence), and Canonical Specification (generating a standardized command for the segmentation backbone).
  2. SEER-Loop & SEER-Bank: The system maintains a memory bank of "skill artifacts"—reusable reasoning patterns that have proven successful. Using Group Relative Policy Optimization (GRPO), the model distills high-reward reasoning trajectories into the SEER-Bank, learning which skills (e.g., "synonym normalization") work best for specific ambiguities.
  3. SEER-Trace Dataset: To support this reasoning, the authors curated SEER-Trace, a dataset of 22,330 multimodal instances pairing clinical requests with image-grounded, skill-tagged reasoning traces.

Experimental Results

SEER was evaluated against state-of-the-art models like VoxTell and MedSAM3 across multiple datasets, including BrainMetShare and the out-of-distribution (OOD) PENGWIN dataset.

Qualitative comparison of SEER against state-of-the-art models under various linguistic challenges like typos and complex clinical intent.

Robustness to Linguistic Noise

As shown in the qualitative results, SEER remains highly stable even when faced with "typo noise" (e.g., "sacrun" instead of "sacrum") or complex "clinical intent" descriptions. While baseline models often fail to segment the correct region or produce fragmented masks under these conditions, SEER's reasoning layer acts as a semantic buffer, ensuring the segmentation backbone receives a clear, grounded instruction.

Quantitative Performance

Quantitative analysis confirms these visual findings:

  • Stability: Under linguistic perturbations, SEER reduced performance variance by 81.94%.
  • Worst-Case Robustness: It improved "worst-case" Dice scores by 18.60%, indicating significantly fewer catastrophic failures.
  • Zero-Shot Generalization: On the OOD PENGWIN dataset, SEER maintained a high Dice score of 97.39, demonstrating its ability to generalize to unseen anatomical regions by relying on its library of reasoning skills.

Conclusion

SEER represents a significant step toward making medical AI assistants more practical for clinical use. By treating reasoning as a set of discrete, auditable, and evolving "skills," the framework bridges the gap between messy human language and precise anatomical segmentation. Future work will look to expand the skill taxonomy to handle more complex diagnostic tasks and further refine automated auditing of the model's logical rationales.

Summary updated

Abstract

Free-text promptable 3D medical image segmentation offers an intuitive and clinically flexible interaction paradigm. However, current methods are highly sensitive to linguistic variability: minor changes in phrasing can cause substantial performance degradation despite identical clinical intent. Existing approaches attempt to improve robustness through stronger vision-language fusion or larger vocabularies, yet they lack mechanisms to consistently align ambiguous free-form expressions with anatomically grounded representations. We propose Skill-Evolving grounded Reasoning (SEER), a novel framework for free-text promptable 3D medical image segmentation that explicitly bridges linguistic variability and anatomical precision through a reasoning-driven design. First, we curate the SEER-Trace dataset, which pairs raw clinical requests with image-grounded, skill-tagged reasoning traces, establishing a reproducible benchmark. Second, SEER constructs an evidence-aligned target representation via a vision-language reasoning chain that verifies clinical intent against image-derived anatomical evidence, thereby enforcing semantic consistency before voxel-level decoding. Third, we introduce SEER-Loop, a dynamic skill-evolving strategy that distills high-reward reasoning trajectories into reusable skill artifacts and progressively integrates them into subsequent inference, enabling structured self-refinement and improved robustness to diverse linguistic expressions. Extensive experiments demonstrate superior performance of SEER over state-of-the-art baselines. Under linguistic perturbations, SEER reduces performance variance by 81.94% and improves worst-case Dice by 18.60%.
BibTeX
@misc{zhang2026skill,
  author = {Tongrui Zhang and Chenhui Wang and Yongming Li and Zhihao Chen and Xufeng ZHAN and Hongming Shan},
  title = {{Skill-Evolving Grounded Reasoning for Free-Text Promptable 3D Medical Image Segmentation}},
  year = {2026},
  eprint = {2603.08215},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2603.08215},
}
Figure