Abstract
Automated medical image segmentation plays an important role in many clinical applications, which however is a very challenging task, due to complex background texture, lack of clear boundary and significant shape and texture variation between images. Many researchers proposed an encoder-decoder architecture with skip connections to combine low-level feature maps from the encoder path with high-level feature maps from the decoder path for automatically segmenting medical images. The skip connections have been shown to be effective in recovering fine-grained details of the target objects and may facilitate the gradient back-propagation. However, not all the feature maps transmitted by those connections contribute positively to the network performance. In this paper, to adaptively select useful information to pass through those skip connections, we propose a novel 3D network with self-supervised function, named selective information passing network (SIP-Net). We evaluate our proposed model on the MICCAI Prostate MR Image Segmentation 2012 Grant Challenge dataset, TCIA Pancreas CT-82 and MICCAI 2017 Liver Tumor Segmentation (LiTS) Challenge dataset. The experimental results across these data sets show that our model achieved improved segmentation results and outperformed other state-of-the-art methods.
Introduction
Automated medical image segmentation—identifying the exact boundaries of organs or tumors in MRI and CT scans—is notoriously difficult. Medical images often suffer from fuzzy boundaries, complex background textures, imaging artifacts, and high variability in organ shape across different slices. To tackle this, the field heavily relies on encoder-decoder architectures (like U-Net or V-Net) that use "skip connections." These connections bypass the bottleneck of the network, feeding high-resolution, low-level feature maps directly into the decoder to help recover fine-grained details.
However, a critical flaw exists: standard skip connections pass all information indiscriminately. In medical images where the background is noisy or shares similar intensity with the target organ, these connections feed irrelevant, confusing features to the decoder, leading to noisy and inaccurate segmentations. Furthermore, 3D CNNs designed to capture volumetric context often have massive parameter counts, making them highly prone to overfitting on the small datasets typical in medical imaging.
Methods
To solve the "noisy skip connection" problem, we propose the Selective Information Passing Network (SIP-Net). The architecture introduces two major innovations over standard 3D Fully Convolutional Networks (FCNs):
Attention-focused Modules (AMs)
Instead of wiring the encoder directly to the decoder, SIP-Net places an AM on every long skip connection. The AM uses a sigmoid layer to generate an attention mask (values between 0 and 1), which is element-wise multiplied with the incoming feature map. This acts as a gatekeeper, suppressing background noise and allowing only features relevant to the target organ to pass through. Visualizations show that the network learns to generate a heatmap that tightly bounds the target organ early in the up-sampling path.
Densely-connected Residual Blocks (DRBs)
To combat the vanishing gradient problem and keep parameter counts low, the network's core building blocks combine dense connections with residual connections. This encourages massive feature reuse, allowing SIP-Net to be over 100 layers deep while containing only approximately 3.16 million parameters. This architectural choice makes the model significantly more data-efficient than standard FCNs.
Deep Supervision
To ensure the AMs learn to filter correctly, the network employs deep supervision. Auxiliary loss functions are attached after each deconvolutional layer, forcing the network to evaluate segmentation quality at multiple scales and explicitly guiding the formation of effective attention masks.
Experimental Results
The model was evaluated on three benchmark datasets: MICCAI PROMISE12 (Prostate MRI), TCIA Pancreas CT-82, and MICCAI 2017 LiTS Challenge (Liver CT).
Key Performance Metrics
- Prostate (PROMISE12): SIP-Net achieved a Dice Similarity Coefficient (DSC) of 91.42%, ranking 1st place on the challenge leaderboard as of May 2018. It showed particularly strong improvements in the notoriously difficult apex and base regions of the prostate.
- Pancreas (CT-82): Achieved a DSC of 83.9 ± 4.5%, outperforming several state-of-the-art 2D and 3D models, including Attention U-Net.
- Liver (LiTS): Achieved a Global DSC of 94.6% (3D model) and 96.3% (2D model), placing among the top seven teams on the leaderboard. Inference is highly efficient, taking only 1-2 minutes per 3D volume.
Discussion and Conclusion
SIP-Net demonstrates that skip connections are a double-edged sword; while they provide necessary detail, gating this information is essential in noisy medical imaging domains. The combination of Attention-focused Modules and Densely-connected Residual Blocks allows for high accuracy with fewer parameters.
One notable observation from the LiTS dataset is that the 2D version of SIP-Net outperformed the 3D version. While 3D CNNs capture better spatial context, their higher parameter counts make them harder to train on datasets with limited volume counts or variable slice spacing. Future work will focus on bridging this gap through hybrid 2.5D approaches or advanced regularization for volumetric data.
Summary updated