Search for MeV-Scale Axionlike Particles and Dark Photons with PandaX-4T

PandaX Collaboration, Tao Li, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Zhaokan Cheng, Xiangyi Cui, Yingjie 英杰 Fan 樊, Deqing Fang, Zhixing Gao, Li‐Sheng Geng, Karl Giboni, Xunan Guo, Xuyuan Guo, Zichao Guo, Chencheng Han, Ke HanChangda He, Jinrong He, Di Huang, Houqi Huang, J. Huang, Ruquan Hou, Yu Hou, Xiangdong Ji, Xiangpan Ji, Yonglin Ju, Chenxiang Li, Jiafu Li, Mingchuan Li, Shuaijie Li, Zhiyuan Li, Qing Lin, Jianglai Liu, Congcong Lu, Xiaoying Lü, Lingyin Luo, Yunyang Luo, Wenbo Ma, Y. G., Yajun Mao, Yue Meng, Xuyang Ning, Binyu Pang, Ningchun Qi, Zhicheng Qian, Xiangxiang Ren, Dong Shan, Xiaofeng Shang, Xiyuan Shao, Guofang Shen, Manbin Shen, Wenliang Sun, Yi Tao, Anqing Wang, Guanbo Wang, Hao Wang, Jiamin Wang, Lei Wang, Meng Wang, Qiuhong Wang, Shaobo Wang, Siguang Wang, Wei Wang, Xiuli Wang, Xu Wang, Zhou Wang, Yuehuan Wei, Weihao Wu, Yuan Wu, Mengjiao Xiao, Xiang Xiao, Kaizhi Xiong, Yifan Xu, Shunyu Yao, Binbin Yan, Xiyu Yan, Yong Yang, Peihua Ye, Chunxu Yu, Ying Yuan, Zhe Yuan, Youhui Yun, Xinning Zeng, Minzhen Zhang, P. Zhang, Shibo Zhang, Shu Zhang, Tao Zhang, Wei Zhang, Yang Zhang, Yingxin Zhang, Yuanyuan Zhang, Li Zhao, Jifang Zhou, Jiaxu Zhou, Jiayi Zhou, Ning Zhou, Xiaopeng Zhou, Yubo Zhou · DOI

Abstract: Axionlike particles (ALPs) and dark photons (DPs) are viable dark matter particle candidates. We have searched for possible ALP/DP signals in the PandaX-4T liquid xenon detector using 440 kg$\cdot$yr of data. A binned likelihood fit is constructed to search for possible mono-energetic peaks induced by the absorption processes between ALPs/DPs and atomic electrons of xenon. A detailed temporal model of decays associated with xenon isotopes is introduced to constrain the number of background events. No signal excess over background expectations is observed, and we have established the most stringent exclusion limits for most ALP/DP masses across the range of 150 keV/$c^2$ to 1 MeV/$c^2$. The improvement is particularly significant within the mass range of 150-400 keV/$c^2$, with the average factor of 3.5 compared to previous results.

Introduction

For decades, the search for dark matter has been dominated by the hunt for Weakly Interacting Massive Particles (WIMPs). However, the persistent absence of a definitive WIMP signal has prompted the physics community to broaden its scope toward alternative candidates. Among the most promising are "bosonic super-WIMPs," specifically Axionlike Particles (ALPs) and Dark Photons (DPs).

Unlike WIMPs, which typically interact via nuclear recoil, ALPs and DPs can be absorbed by atoms through a process analogous to the photoelectric effect. In a liquid xenon detector, this absorption would release an electron with a kinetic energy nearly equal to the rest mass of the dark matter particle, resulting in a distinct "mono-energetic" peak in the energy spectrum.

Methodology and Data Collection

The PandaX Collaboration conducted this search using the PandaX-4T detector, a dual-phase time projection chamber (TPC) containing 3.7 tons of liquid xenon, located in the ultra-low-background environment of the China Jinping Underground Laboratory. The analysis utilized a total exposure of 440 kg·yr, split between the commissioning run (Run0) and the first scientific run (Run1).

A major challenge in this energy regime (150 keV to 1 MeV) is the presence of radioactive backgrounds, particularly short-lived xenon isotopes ($^{127}$Xe, $^{129m}$Xe, and $^{131m}$Xe) produced during calibration or through cosmogenic activation. To address this, the team implemented a sophisticated temporal background model. By tracking the decay rates of these isotopes over time, they could distinguish between fading radioactive noise and a potential persistent dark matter signal.

Temporal evolution of event rates for xenon isotopes.

Furthermore, energy reconstruction was improved by calibrating the detector response using alpha signals from $^{222}$Rn progenies. This refinement improved the energy resolution from 3.6% to 3.0% at 208 keV, enhancing the detector's ability to resolve narrow energy peaks.

Results and Discussion

The researchers performed a joint binned likelihood fit across both datasets, searching for signal excesses that would indicate the presence of ALPs or DPs. The data were found to be highly consistent with the background-only model, yielding a p-value of 0.51.

In the absence of a signal, new 90% confidence level (C.L.) upper limits were set on the coupling constants: $g_{ae}$ for ALPs and $\kappa$ for DPs. These results represent the most stringent constraints to date for masses between 150 keV/$c^2$ and 1 MeV/$c^2$.

Exclusion limits for ALPs and Dark Photons.

The improvement is most notable in the 150–400 keV/$c^2$ range, where the PandaX-4T limits are, on average, 3.5 times stronger than previous results from experiments such as GERDA, COSINE-100, and XMASS. At the lower end of the mass range (150 keV/$c^2$), the sensitivity improvement reached a factor of 13.4.

Conclusion and Future Outlook

The PandaX-4T experiment has successfully demonstrated the power of liquid xenon detectors in probing the MeV-scale bosonic dark matter landscape. By leveraging precise temporal modeling and improved energy resolution, the collaboration has significantly pushed back the boundaries of the unknown.

Looking forward, the team is developing "multi-site" event analysis techniques to improve sensitivity at higher mass scales, where dark matter interactions are more likely to involve Compton-like scattering. With the ongoing Run2 and planned detector upgrades, PandaX-4T remains at the forefront of the global effort to uncover the nature of dark matter.

Summary updated

Abstract

Axionlike particles (ALPs) and dark photons (DPs) are viable dark matter particle candidates. We have searched for possible ALP/DP signals in the PandaX-4T liquid xenon detector using 440 kg$\cdot$yr of data. A binned likelihood fit is constructed to search for possible mono-energetic peaks induced by the absorption processes between ALPs/DPs and atomic electrons of xenon. A detailed temporal model of decays associated with xenon isotopes is introduced to constrain the number of background events. No signal excess over background expectations is observed, and we have established the most stringent exclusion limits for most ALP/DP masses across the range of 150 keV/$c^2$ to 1 MeV/$c^2$. The improvement is particularly significant within the mass range of \text{150-400}~keV/$c^2$, with the average factor of 3.5 compared to previous results.
BibTeX
@inproceedings{collaboration2025search,
  author = {PandaX Collaboration and Tao Li and Zihao Bo and Wei Chen and Xun Chen and Yunhua Chen and Zhaokan Cheng and Xiangyi Cui and Yingjie 英杰 Fan 樊 and Deqing Fang and Zhixing Gao and Li‐Sheng Geng and Karl Giboni and Xunan Guo and Xuyuan Guo and Zichao Guo and Chencheng Han and Ke HanChangda He and Jinrong He and Di Huang and Houqi Huang and J. Huang and Ruquan Hou and Yu Hou and Xiangdong Ji and Xiangpan Ji and Yonglin Ju and Chenxiang Li and Jiafu Li and Mingchuan Li and Shuaijie Li and Zhiyuan Li and Qing Lin and Jianglai Liu and Congcong Lu and Xiaoying Lü and Lingyin Luo and Yunyang Luo and Wenbo Ma and Y. G. and Yajun Mao and Yue Meng and Xuyang Ning and Binyu Pang and Ningchun Qi and Zhicheng Qian and Xiangxiang Ren and Dong Shan and Xiaofeng Shang and Xiyuan Shao and Guofang Shen and Manbin Shen and Wenliang Sun and Yi Tao and Anqing Wang and Guanbo Wang and Hao Wang and Jiamin Wang and Lei Wang and Meng Wang and Qiuhong Wang and Shaobo Wang and Siguang Wang and Wei Wang and Xiuli Wang and Xu Wang and Zhou Wang and Yuehuan Wei and Weihao Wu and Yuan Wu and Mengjiao Xiao and Xiang Xiao and Kaizhi Xiong and Yifan Xu and Shunyu Yao and Binbin Yan and Xiyu Yan and Yong Yang and Peihua Ye and Chunxu Yu and Ying Yuan and Zhe Yuan and Youhui Yun and Xinning Zeng and Minzhen Zhang and P. Zhang and Shibo Zhang and Shu Zhang and Tao Zhang and Wei Zhang and Yang Zhang and Yingxin Zhang and Yuanyuan Zhang and Li Zhao and Jifang Zhou and Jiaxu Zhou and Jiayi Zhou and Ning Zhou and Xiaopeng Zhou and Yubo Zhou},
  title = {{Search for MeV-Scale Axionlike Particles and Dark Photons with PandaX-4T}},
  booktitle = {Physical},
  year = {2025},
  doi = {10.1103/physrevlett.134.071004},
}
Figure