Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining

Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel, Akshay S. ChaudhariarXiv 2026 · arXiv

TL;DR

Researchers have developed a training-free, offline data curation method that allows 3D medical vision-language models (VLMs) to match state-of-the-art performance using up to 10x less data. By using a small, high-quality reference set to "anchor" the selection process, the method effectively filters out noise and redundancy while naturally enriching rare clinical findings.

What Problem Does This Paper Address?

Training powerful Vision-Language Models (VLMs) for 3D medical imaging, such as CT scans, typically requires massive datasets of paired volumes and radiology reports. However, "more data" isn't always "better data." Real-world hospital archives are messy: they are filled with redundant "normal" scans, suffer from extreme class imbalances (rare diseases are, well, rare), and vary significantly across different institutions due to different scanner protocols.

Manually curating these datasets is prohibitively expensive because it requires expert radiologist time. Standard automated methods, like simple CLIP-score filtering or random sampling, often fail to capture the nuanced quality needed for specialized medical tasks. This paper tackles the challenge of identifying the most informative samples from a large, uncurated pool without needing additional labels or expensive training runs.

Methods

The authors propose a Reference-Guided Data Curation pipeline. The core idea is to use a small, expert-curated "reference set" ($D_{ref}$) as a proxy for high quality and desired distribution.

Figure 1. Overview of the proposed offline multimodal curation pipeline. We leverage a small, high-quality reference set (Dref) to guide selection from a large uncurated pool (D0). Vision and text streams independently perform k-nearest neighbors (k-NN) retrieval to produce initial rankings (rV , rT ). These are merged via Reciprocal Rank Fusion (RRF), and the top N samples form the curated subset.

The process works in three main steps:

  1. Independent Modality Ranking: For every sample in the large uncurated pool, the system calculates its similarity to the reference set.
  2. Vision: Uses DreamSim, a perceptual similarity encoder, to find the $k$-nearest neighbors in the pool for each reference image.
  3. Text: Uses Clinical Longformer to do the same for radiology reports.
  4. Multimodal Fusion: Instead of simple averaging, they use Reciprocal Rank Fusion (RRF). This late-fusion technique merges the vision and text rankings into a single list. RRF is particularly robust because it doesn't require normalizing scores across different embedding spaces.
  5. Selection: The top $N$ samples from the final fused ranking are selected for pretraining.

This approach is entirely "offline" and "training-free," meaning you don't need to train a model just to decide what data to train on.

Datasets

The method was validated across two major modalities:

  • 3D Abdominal CT: Used the Merlin dataset (~35k volume-report pairs) from two institutions. The reference set was a 5k-sample validation split.
  • 2D Chest X-ray (CXR): Used CheXpert Plus (~58k pairs) for training and MIMIC-CXR for out-of-distribution (OOD) evaluation. Remarkably, the reference set here was as small as 74 samples.

Key Insights and Ideas

  • Implicit Enrichment of Rare Findings: One of the most striking "aha moments" is that similarity-based retrieval naturally acts as a prevalence filter. By aligning with a high-quality reference, the system automatically downsamples "unremarkable" normal scans and upsamples rare, clinically significant pathologies like Renal Hypodensities or Hepatomegaly.
  • Weakening the Prevalence Bias: Standard models often perform better on common diseases simply because they see them more often. This curation method weakens that correlation (reducing Pearson's $r$ from 0.35 to -0.16), ensuring that performance on rare "tail-end" findings is preserved even with a smaller training budget.
Curation weakens dependence on training-set prevalence while preserving rare-finding performance.
  • Late Fusion Wins: The authors found that "early fusion" (concatenating embeddings before retrieval) was unstable. RRF's ability to independently value high-quality text and high-quality images before merging them proved far more effective for medical data.

Key Results

The results demonstrate that smart curation can drastically reduce computational costs:

  • 3.3x Data Efficiency on 3D CT: A model trained on just 4.5k curated samples matched the zero-shot performance (0.741 F1) of a baseline trained on the full 15k dataset.
  • 10x Data Efficiency on 2D CXR: The curated model matched or exceeded full-pool performance while using 10x less training data.
  • Superior Baselines: The RRF-guided selection outperformed all common baselines, including random sampling, k-means clustering, and CLIP-score filtering, by margins of 0.09 to 0.21 in F1 score.
Figure 2. Zero-shot findings classification performance. (a) i) Our RRF curation strategy matches baseline performance (0.741 in F1) using 3.3× less training data. ii) Training on randomly sampled sets from the uncurated dataset or the full Merlin Abdominal CT dataset (Merlin baseline) yields suboptimal cross-institutional performance, reaching 0.635 and 0.689 F1 scores respectively. We plot the best models across k value choices (k-NN hyperparameter) for each training data scale and method (text-only, vision-only, RRF). Error bars correspond to 95% confidence intervals. (b) Comparison of Merlin vs. external Tri-Valley (TV) dataset F1 scores. RRF models trace the Pareto frontier.

Limitations and Future Work

While powerful, the method's success depends on the quality and representativeness of the small reference set. If the reference set is biased or low-quality, the curation will follow suit. Additionally, while the method showed great cross-institutional promise, the "Tri-Valley" dataset used for OOD testing is private, which limits full external reproducibility of those specific results.

Future work could explore how to automatically generate or augment these reference sets to further reduce the need for any initial expert curation.

Summary updated

Abstract

Training 3D vision-language models (VLMs) on large medical imaging datasets collected across institutions is constrained by data quality. Vast, uncurated pools of image-report pairs are characterized by redundancy, class imbalance, and cross-institutional heterogeneity. We address this challenge of data curation for improving 3D VLM pretraining by proposing an offline, training-free, reference-guided data curation recipe. Our approach leverages a small, high-quality reference set to independently extract quality signals for each modality of a large, uncurated pool and merges them through a rank-aggregation step into a single ranking that guides sample selection. We validate this method on datasets comprising 35k 3D abdominal CT volume-report pairs from two institutions and 58k 2D chest X-ray image-report pairs. On 3D CT, using our reference-guided data curation strategy, our curated model matches the zero-shot disease classification performance of a state-of-the-art baseline (Merlin) while using $3.3\times$ less training data and a reference set of 5k samples. On 2D chest X-rays, our method yields a curated model that matches or exceeds the zero-shot disease classification performance of a model trained on the full pool while using up to $10\times$ less training data and a reference set of only 74 samples. Ablations show that the selection is stable under resampling of the reference, that smaller reference sets still outperform random sampling, and that label rebalancing does not improve performance. To support reproducibility, we release our code.
BibTeX
@misc{patsatzi2026reference,
  author = {Faidra Patsatzi and Ashwin Kumar and Chong Wang and Curtis P. Langlotz and Reinhard Heckel and Akshay S. Chaudhari},
  title = {{Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining}},
  year = {2026},
  eprint = {2611.23484},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.23484},
}
Figure