Rapid Model Transfer for Medical Image Segmentation Via Iterative Human-in-the-Loop Update: from Labelled Public to Unlabelled Clinical Datasets for Multi-Organ Segmentation in CT

Wenao Ma, Shuang Zheng, Lei Zhang, Huimao Zhang, Qi Dou

Introduction

Deep learning has revolutionized medical image segmentation, yet deploying these models in clinical practice remains a significant challenge. The primary obstacle is "domain shift"—the performance degradation that occurs when a model trained on curated public datasets is applied to real-world clinical data from different scanners, protocols, or patient populations. Traditionally, overcoming this shift requires clinicians to manually annotate large volumes of clinical data for fine-tuning, a process that is both labor-intensive and prohibitively expensive.

This paper introduces a Human-in-the-Loop (HITL) framework designed to facilitate rapid model transfer from small, labeled public datasets to large, unlabeled clinical datasets. By optimizing the interaction between the human expert and the AI, the researchers demonstrate that it is possible to achieve high-accuracy multi-organ segmentation with a fraction of the manual effort.

The Igniter-Sustainer Framework

The proposed framework utilizes a two-stage iterative approach involving two distinct neural networks:

  1. The Igniter Network: Trained on a small, publicly available labeled dataset (e.g., the ISBI 2019 CHAOS Challenge), the Igniter serves as the starting point. Its role is to provide "coarse" initial annotations on the target clinical data. While these predictions are not perfect, they provide a baseline that is significantly faster to edit than creating labels from scratch.
  2. The Sustainer Network: This is a high-capacity model, specifically the TransUNet architecture, which integrates the strengths of Transformers and U-Net. The Sustainer is iteratively trained on the clinical data as it is refined by human experts.

The HITL Loop

The transfer process follows a cyclical workflow:

  • The Igniter generates initial labels for the clinical dataset.
  • A clinician reviews and edits these labels, focusing on specific samples.
  • The Sustainer is trained on the newly refined labels.
  • In subsequent rounds, the Sustainer generates increasingly accurate predictions for the remaining unlabeled data, which are then further refined by the clinician.

Strategic "Easy-to-Hard" Labeling

A key contribution of this research is the departure from traditional active learning strategies. While most active learning methods prioritize labeling the most "uncertain" or difficult samples to maximize information gain, the authors propose an "easy-to-hard" strategy.

In a clinical setting, the bottleneck is the radiologist's time. The authors found that labeling "easy" samples—those the model already handles relatively well—is more efficient in the early stages. Clinicians can correct these samples rapidly, allowing for a higher volume of high-quality training data to be fed back into the Sustainer quickly. This approach stabilizes model performance faster and provides a more encouraging workflow for the human annotator.

Experimental Evaluation

The framework was evaluated by transferring a model from the ISBI 2019 CHAOS Challenge dataset (30 CT and 20 MRI scans) to a private clinical dataset of 551 patients from The First Hospital of Jilin University. The target task was the segmentation of the liver and spleen in contrast-enhanced abdominal CT scans.

Performance and Efficiency Gains

The results highlight a dramatic improvement in both model accuracy and human productivity:

  • Accuracy: The iterative transfer process improved the segmentation Dice score by 19.7% over the baseline Igniter model.
  • Time Savings: The average manual labeling time per CT volume plummeted from 13.87 minutes (for purely manual annotation) to just 1.51 minutes by the final iteration.
  • Rapid Convergence: The efficiency of the "easy-to-hard" strategy was evident early on; after a clinician edited only 15 "easy" cases (taking approximately 14 minutes each), the liver segmentation Dice score rose from 78.74% to 90.74%.

Discussion and Limitations

The study underscores that in clinical AI, "efficiency" must be measured by the expert's time rather than just the number of samples. By providing the model with "good enough" labels across a larger volume of images early in the process, the Sustainer converges more effectively than if the expert spent the same amount of time perfecting a handful of difficult cases.

However, the study notes some limitations. The efficiency gains were measured using a highly experienced radiologist (10+ years), and results might vary with different levels of expertise or different annotation interfaces. Furthermore, while the framework was successful for the liver and spleen, extending this to more complex, smaller, or highly variable structures like the pancreas remains a subject for future research.

Conclusion

This HITL framework provides a practical pathway for hospitals to adapt powerful AI models to their specific clinical environments without the need for exhaustive manual labeling. By prioritizing human efficiency and utilizing an iterative "easy-to-hard" refinement process, the gap between public research and clinical utility can be bridged rapidly and effectively.

Summary updated