TL;DR
This paper presents data-driven models capable of rapidly estimating energy expenditure during walking using wearable sensors. These models achieve good accuracy even for new subjects and conditions, paving the way for real-time optimization of assistive devices and rehabilitation strategies outside of lab settings.
What Problem Does This Paper Address?
Estimating energy expenditure (EE) is crucial for understanding human movement efficiency, especially for individuals with ambulatory disabilities. Traditional methods like indirect calorimetry are accurate but cumbersome, expensive, and slow, making them impractical for real-time applications like optimizing assistive devices or gait retraining. While wearable sensors offer a path to rapid EE estimation, existing methods often fail to demonstrate their accuracy for conditions or subjects not included in the initial training data. This paper tackles the challenge of developing and evaluating data-driven models that can generalize well to novel walking scenarios and individuals, aiming to bridge the gap between lab-based accuracy and real-world applicability.
Methods
The researchers developed and compared two primary model architectures: linear regression and neural networks. They focused on extracting features from wearable sensor data (ground reaction forces and electromyography - EMG) that could be measured with portable sensors. To enable rapid estimation, they restricted the input data to either a single gait cycle or a fixed four-second interval.
Key methodological aspects include:
- Feature Engineering: Data was processed by filtering and then either segmented by gait cycle (averaged into bins) or by fixed time intervals. EMG signals were rectified and normalized.
- Model Architectures:
- Gait Cycle Models: Linear regression and neural networks (3-4 layers, 300-1000 neurons) were trained using a Mean Absolute Error (MAE) loss function.
- Fixed Time Interval Models: A Long Short-Term Memory (LSTM) recurrent neural network was employed to capture temporal dependencies.
- Evaluation Framework: The models were evaluated across three distinct "use cases" to assess their generalization capabilities:
- Condition Use Case: Estimating EE for new walking conditions within subjects who have some training data.
- Subject Use Case: Estimating EE for all conditions for a completely new subject.
- Novel Use Case: Estimating EE for a new subject performing new conditions.
- Ordering Task: Beyond direct EE estimation, the models were also evaluated on their ability to correctly order the magnitude of EE across different walking conditions for a new subject.
Datasets
The study utilized two distinct datasets:
- Assisted Walking Dataset: Collected from eight subjects walking with an ankle exoskeleton providing various assistance strategies. This dataset included ground reaction forces and EMG from eight muscles on both legs.
- Inclined Loaded Walking Dataset: Collected from thirteen subjects walking under different load (0-30% bodyweight) and incline (0-10%) conditions. This dataset included ground reaction forces and EMG from eight muscles on one leg.
These datasets represent real-world walking scenarios with variations in assistance, load, and incline, serving as benchmarks for evaluating the models' generalization performance.
Key Insights and Ideas
- Generalization is Achievable: The study demonstrates that data-driven models can achieve reasonable accuracy in estimating energy expenditure for subjects and conditions not seen during training. This is a critical step towards practical, real-world applications.
- Gait Cycle Segmentation is Key: Models that segment data by gait cycle generally outperformed those using fixed time intervals, suggesting that capturing the cyclical nature of walking is important for accurate EE estimation.
- Ordering Matters for Optimization: The ability of models to correctly order the magnitude of energy expenditure across different conditions is a valuable finding. This capability could directly inform the selection of optimal assistive device settings or rehabilitation protocols.
- Feature Importance Varies: For inclined loaded walking, ground reaction forces were more critical for accurate estimation, likely because they encapsulate more information about the walking task (load, incline). For assisted walking, the importance of features was more balanced.
- Wearable Sensor Data Sufficiency: The research suggests that readily available wearable sensor data (ground reaction forces and EMG) can be sufficient for robust EE estimation, even with minimal preprocessing.
Key Results
- Error Rates:
- Assisted Walking: Average errors for the three use cases were 4.4% (Condition), 8.0% (Subject), and 8.1% (Novel).
- Inclined Loaded Walking: Average errors were 6.1% (Condition), 9.7% (Subject), and 11.7% (Novel).
- Ordering Performance:
- Inclined Loaded Walking: Maximum and average correct ordering percentages were 83% and 54% (neural network), and 85% and 55% (for the ordering task itself).
- Assisted Walking: Maximum and average correct ordering percentages were 56% and 43%.
- Model Comparison: Neural networks generally performed slightly better or comparably to linear regression, especially in the more challenging "novel" use case.
- Input Feature Impact: Restricting inputs to only vertical ground reaction force and EMG increased error by a small margin (0.3%) compared to using all available signals.
Limitations and Future Work
- Data Limitations: The authors acknowledge that the performance of data-driven models is highly dependent on the training data. A truly generalizable model would require significantly more data across a wider range of conditions and subjects.
- Extreme Conditions: Estimating EE for conditions at the extremes of the dataset (e.g., highest exoskeleton work) proved more difficult, leading to higher errors.
- Noise Sensitivity: While models showed some robustness to noisy signals, the presence of noise from wearable sensors can still impact performance.
- Future Directions: The authors suggest that fine-tuning features, incorporating more wearable sensor measurements, and expanding the dataset are crucial for improving model accuracy and generalizability. They also highlight the potential for these models to be used in "human-in-the-loop" systems for real-time optimization.
Summary updated