Randomization improving online time-sensitive revenue maximization for green data centers

Huangxin Wang, Jean X. Zhang, Bo Yang, Fei Li

Abstract

Data centers face significant operational costs due to high energy consumption. Integrating renewable "green" energy can mitigate costs, but its intermittency, combined with unpredictable job arrivals, creates a complex online scheduling problem. This paper introduces Random-Fit (RF), a randomized online algorithm designed for Green Data Center Revenue Management (GDC-RM). Unlike deterministic heuristics like First-Fit or Best-Fit, which are vulnerable to adversarial workloads, RF strategically injects randomness into scheduling decisions. We prove that RF achieves a theoretical competitive ratio of 1.25 for uniform job lengths. Empirical results using Grid5k traces and real-world solar data confirm that RF outperforms standard heuristics by providing a robust balance between throughput and energy costs across diverse utilization levels.

Introduction

Data centers are the backbone of modern digital services but are also massive energy sinks, with power costs often exceeding 70% of operational expenses. To enhance sustainability and reduce reliance on the traditional power grid ("brown energy"), operators are increasingly turning to on-site renewable sources ("green energy"). However, the stochastic nature of both job requests and green energy supply makes real-time revenue management exceptionally difficult. The core challenge lies in the uncertainty of the future: a manager must decide in real-time whether to admit a job, when to schedule it, and which energy source to utilize without knowing future demand or weather conditions.

System Model and Problem Formulation

The GDC-RM problem involves three critical real-time decisions: job admission, scheduling, and energy sourcing. The goal is to maximize net profit—defined as the revenue from completed jobs minus the cost of brown energy consumed.

System model for Green Data Center Revenue Management.

As illustrated in the system model, the Revenue Management unit acts as a central dispatcher, receiving job requests from users and energy from both green and brown sources. It must then dispatch these jobs to available machines in a way that optimizes the trade-off between immediate service and long-term energy efficiency.

Methodology: The Random-Fit Algorithm

The paper’s primary contribution is the Random-Fit (RF) algorithm. Deterministic algorithms like First-Fit (prioritizing early completion) or Best-Fit (prioritizing cost-efficiency) often fall into "traps" set by specific workload patterns. For instance, a greedy approach might exhaust machine slots, leaving no room for high-value future jobs, while a cost-efficient approach might delay jobs until they miss their deadlines.

RF avoids these pitfalls by using a randomized strategy:

  • Green Energy Available: RF acts greedily and schedules the job in the earliest possible slot to maximize throughput using free energy.
  • Green Energy Unavailable: Instead of a fixed choice, RF uses a calculated probability $p$ to choose the earliest slot and $1-p$ to choose the most economic slot.

This internal randomness prevents the algorithm from being "trapped" by adversarial input sequences that would cause deterministic algorithms to perform poorly. By introducing this probability-based "twist," Random-Fit effectively hedges its bets against the uncertainty of future green energy availability.

Experimental Results

The authors evaluated RF against First-Fit, Best-Fit, and GreenSlot using workload traces from Grid5k (a large-scale experimental grid in France) and solar energy data from the UMass Amherst weather station. Pricing was modeled on PSEG New Jersey summer rates and Amazon EC2 service revenue.

Lower bound of competitive ratio vs. workload for different algorithms on Grid5k traces.

As shown in the experimental results, the competitive ratio of deterministic algorithms varies significantly with workload. First-Fit performs poorly at low utilization, while Best-Fit's performance degrades as utilization increases beyond 80%. Random-Fit (represented by red diamonds) maintains a consistently low and stable competitive ratio across the entire spectrum. Theoretically, RF achieves a competitive ratio of 1.25, a significant improvement over the lower bound of 2 for deterministic alternatives.

Conclusion

Random-Fit provides a powerful alternative to traditional scheduling heuristics in green data centers. By leveraging randomization, it breaks the theoretical performance ceiling of deterministic approaches and offers superior robustness in real-world scenarios. While the current proof assumes uniform job lengths, empirical results on heterogeneous Grid5k traces are highly promising. Future work will explore the integration of energy storage systems (batteries) to further shift green energy usage across time.

Summary updated

BibTeX
@inproceedings{wang2015randomization,
  author = {Huangxin Wang and Jean X. Zhang and Bo Yang and Fei Li},
  title = {{Randomization improving online time-sensitive revenue maximization for green data centers}},
  booktitle = {IGSC},
  year = {2015},
  doi = {10.1109/igcc.2015.7393689},
}
Figure