RAE: The Rainforest Automation Energy Dataset for Smart Grid Meter Data Analysis

Stephen Makonin, Z. Jane Wang, Chris Tumpach

Abstract

Datasets are important for researchers to build models and test how well their machine learning algorithms perform. This paper presents the Rainforest Automation Energy (RAE) dataset to help smart grid researchers test their algorithms which make use of smart meter data. This initial release of RAE contains 1Hz data (mains and sub-meters) from two residential houses. In addition to power data, environmental and sensor data from the house's thermostat is included. Sub-meter data from one of the houses includes heat pump and rental suite captures which is of interest to power utilities. We also show an energy breakdown of each house and show (by example) how RAE can be used to test non-intrusive load monitoring (NILM) algorithms.

Introduction

To build efficient smart grids, researchers must understand the granular energy consumption of individual appliances. The primary method for achieving this without intrusive hardware is Non-Intrusive Load Monitoring (NILM). NILM uses computational techniques to disaggregate the total power signal from a single smart meter into individual appliance loads. However, the development of robust NILM algorithms is often hindered by datasets that lack high sampling rates, synchronized ground truth data, or environmental context.

The Rainforest Automation Energy (RAE) dataset addresses these gaps by providing 1 Hz power data from two Canadian households. By pairing high-resolution electrical signatures with environmental thermostat data, RAE offers a robust benchmark for perfecting NILM and smart grid analytics.

Methods and Data Acquisition

The authors designed a data capture system using commercial-grade hardware to ensure accuracy and reproducibility. The architecture, shown in Figure 1, integrates multiple data streams to provide a comprehensive view of residential energy use.

The RAE data acquisition system architecture.
  • Aggregate Data: A Rainforest Automation EMU2 in-home display pulls data from ZigBee-enabled smart meters every 15 seconds.
  • Sub-metering: DENT PowerScout 24 meters monitor up to 24 individual circuits (breakers) at a 1 Hz frequency to provide the "ground truth."
  • Environmental Context: EcoBee3 thermostats capture indoor/outdoor temperature, humidity, and motion sensor data at 5-minute intervals.
  • Data Processing: A Raspberry Pi 2B serves as the central data acquisition hub, storing data locally via USB.

The RAE Dataset

The RAE dataset currently includes 72 days of data for House 1 and 59 days for House 2. Unlike existing datasets like REDD, where sub-meters are sampled slower than mains, or AMPds, which uses 1-minute intervals, RAE provides 1 Hz resolution across all metrics. This includes 11 electrical data points such as voltage, current, and power factor.

A 24-hour snapshot of 1 Hz sub-metered power data from House 1.

The 1 Hz sampling rate is identified as the "sweet spot" for residential monitoring—fast enough to capture distinct appliance signatures (as seen in Figure 2) while remaining computationally manageable for standard hardware.

Key Insights and Results

A notable finding in the dataset is the discrepancy between the sum of sub-meters and the utility's smart meter (11–19 kWh over two months). This noise, resulting from hardware accuracy classes and rounding, provides a realistic challenge for algorithm resilience.

To validate the dataset, the authors applied the SparseNILM algorithm to disaggregate six major loads. The testing yielded a Precision of 87.86% and an F-score of 86.41%. The algorithm was highly efficient, processing 5.4 million samples in 46 minutes (approx. 330 µs per sample). While the model excelled at identifying the Heat Pump (the largest energy consumer), it faced challenges with low-frequency loads like the Wall Oven.

Conclusion

The RAE dataset provides a high-resolution, multi-modal resource for the smart grid research community. While currently limited to two houses, it enables advanced studies in occupancy detection, behavior modeling, and NILM. Future work will focus on expanding the dataset to more households and exploring kHz-rate sampling to capture electromagnetic interference signatures.

Summary updated

Abstract

Datasets are important for researchers to build models and test how well their machine learning algorithms perform. This paper presents the Rainforest Automation Energy (RAE) dataset to help smart grid researchers test their algorithms which make use of smart meter data. This initial release of RAE contains 1Hz data (mains and sub-meters) from two a residential house. In addition to power data, environmental and sensor data from the house's thermostat is included. Sub-meter data from one of the houses includes heat pump and rental suite captures which is of interest to power utilities. We also show and energy breakdown of each house and show (by example) how RAE can be used to test non-intrusive load monitoring (NILM) algorithms.
BibTeX
@inproceedings{makonin2018rae,
  author = {Stephen Makonin and Z. Jane Wang and Chris Tumpach},
  title = {{RAE: The Rainforest Automation Energy Dataset for Smart Grid Meter Data Analysis}},
  booktitle = {Data},
  year = {2018},
  url = {https://openreview.net/forum?id=WxdEr3viVPA},
}
Figure