NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Quasi-Monte and Data-Driven Monte Carlo Methods for Efficient Human Joint Model Fitting

Sara Greenberg, John McPhee, Alexander WongJournal of Computational Vision and Imaging Systems 1969

Abstract: Fitting a kinematic model of the human body to an image without the use of markers is a method of pose estimation that is useful for tracking and posture evaluation. This model-fitting is challenging due to the variation in human physique and the large number of possible poses. One type of modeling is to represent the human body as a set of rigid body volumes. These volumes can be registered to a target point cloud acquired from a depth camera using the Iterative Closest Point (ICP) algorithm. The speed of ICP registration is inversely proportional to the number of points in the model and the target point clouds, and using the entire target point cloud in this registration is too slow for real-time applications. This work proposes the use of data-driven Monte Carlo methods to select a subset of points from the target point cloud that maintains or improves the accuracy of the point cloud registration for joint localization in real time. For this application, we investigate curvature of the depth image as the driving variable to guide the sampling, and compare it with benchmark random sampling techniques.

Introduction

Markerless pose estimation—tracking human movement without specialized suits or sensors—is a significant challenge in fields like physiotherapy and home exercise. While consumer depth sensors like the Microsoft Kinect have made this technology accessible, their default skeletal tracking often exhibits inconsistencies, with variability around 10cm. To achieve higher precision, researchers frequently employ the Iterative Closest Point (ICP) algorithm to fit a 3D skeletal model to captured point cloud data. However, the computational cost of ICP scales with the number of points, making real-time processing of dense depth frames (often containing hundreds of thousands of points) difficult on standard hardware.

Methods

The proposed approach utilizes a hybrid sampling strategy to reduce the dataset size while preserving critical geometric features of the human body. The method involves three main components:

  1. Kinematic Modeling: The human upper body is represented as a series of six cylindrical rigid bodies connected by nine spherical joints.
  2. Quasi-Monte Carlo (Sobol) Sampling: Instead of standard random sampling, Sobol sequences are used. This low-discrepancy method ensures a more uniform distribution of points across the space, avoiding the "clumping" typical of purely random selection.
  3. Curvature-Based Sampling: This data-driven component calculates a Hessian matrix for the depth image to estimate surface curvature. Points in high-curvature regions (e.g., elbows, shoulders) are sampled more frequently. These points are highly informative for registration as they define the unique features of the pose.
Human body point cloud with joint markers (left) and the corresponding fitted cylindrical kinematic model (right).

The final sampling model combines these techniques, with 70% of points driven by curvature and 30% by the uniform Sobol sequence to maintain coverage of flatter regions.

Results and Discussion

The study used data from a Microsoft Kinect 2 sensor, with a target point cloud of 217,088 points. Ground truth joint positions were determined via manual inspection. The proposed curvature-aided method was compared against Uniform Random Sampling and pure Sobol Sampling.

Feature Saliency and Accuracy

Prioritizing high-curvature "salient" features allows the ICP algorithm to lock into the correct pose more efficiently than using points from flat areas. Surprisingly, the curvature-aided method using only 200 points achieved an RMSE (Root Mean Squared Error) of under 3cm. In contrast, using the full point cloud (over 200,000 points) resulted in a higher error of 8.79cm, suggesting that excessive data introduces noise or redundancy that degrades the fit.

Comparison of model fitting results using different sampling strategies: Ground Truth, Uniform, Sobol, and the proposed Curvature-based method.

Computational Efficiency

Registration with the full point cloud took 37 seconds per frame. By sampling only 200 points, the computational load was reduced to approximately 0.75 seconds for 10 iterations (per 50 points). Once the sample size exceeded 100 points, the curvature-based method consistently outperformed both uniform random and Sobol sampling in terms of accuracy.

Conclusion and Future Work

While the method significantly improves speed and accuracy, it is not yet fully real-time (typically 30+ FPS). Future work will focus on automating the initialization of cylinder dimensions to adapt to different body types, validating the approach on larger datasets with gold-standard motion capture systems (e.g., Vicon), and extending the kinematic model to full-body tracking.

Summary updated

BibTeX
@article{greenberg1969quasi,
  author = {Sara Greenberg and John McPhee and Alexander Wong},
  title = {{Quasi-Monte and Data-Driven Monte Carlo Methods for Efficient Human Joint Model Fitting}},
  journal = {Journal of Computational Vision and Imaging Systems},
  year = {1969},
  doi = {10.15353/vsnl.v2i1.124},
}
Figure