Progressive Adversarial Semantic Segmentation

Abdullah-Al-Zubaer Imran, Demetri Terzopoulos

Introduction

Deep learning models for medical image segmentation, such as identifying lung boundaries or retinal blood vessels, often suffer from a lack of robustness known as "domain shift." A model trained on data from one hospital may fail when applied to images from another due to differences in equipment, lighting, or patient demographics. While Unsupervised Domain Adaptation (UDA) can mitigate this, it typically requires access to unlabeled data from the target domain during training—a luxury not always available in clinical settings.

To address this, the authors propose Progressive Adversarial Semantic Segmentation (PASS), a framework designed to be inherently robust and "shape-aware," allowing it to generalize to new data sources "out of the box" without target-domain fine-tuning.

The PASS Framework

The PASS architecture is built upon three innovative pillars designed to enforce anatomical consistency and multi-scale structural integrity.

The PASS architecture featuring progressive side-supervision, multi-scale discriminators ($D_2, D_4, D_8$), and a shape encoder ($E$).

1. Progressive Side-Supervision

Unlike standard architectures that only supervise the final output, PASS generates segmentation masks at multiple resolutions ($1/8$, $1/4$, and $1/2$ of the original size). Each "side-output" is evaluated by its own dedicated discriminator ($D_2, D_4, D_8$). This multi-scale feedback forces the network to maintain structural integrity throughout the decoding process, capturing both fine vessel branches and large anatomical structures.

2. Adversarial Shape Awareness

A dedicated Shape Encoder ($E$) learns to map both ground-truth and predicted masks into a latent space. By minimizing the distance between these latent vectors, the model is penalized for producing anatomically impossible shapes. This ensures that even when pixel intensities vary across domains, the global structure (e.g., the characteristic shape of a lung) remains consistent.

3. Consistency via Transformation

The model employs a transformation function $g(x)$ to create augmented versions of training data. By using Kullback-Leibler (KL) divergence to ensure consistent predictions between original and transformed images, the model learns to ignore domain-specific noise and focus on underlying anatomy.

Experimental Evaluation

The study validated PASS using eight public datasets across two distinct tasks:

  • Retinal Vessel Segmentation: ARIA, CHASE, DRIVE, STARE, and HRF.
  • Lung Segmentation: MCU (Montgomery County), JSRT, and CHN (Shenzhen).

These datasets represent a wide variety of imaging configurations, making them ideal for testing cross-domain generalization.

Results and Qualitative Analysis

PASS consistently outperformed standard models like U-Net and advanced variants like AU-Net in both in-domain and cross-domain scenarios.

Qualitative comparison of PASS against baseline models for lung (left) and retinal vessel (right) segmentation across different datasets.

Key Findings:

  • Superior Generalization: For lung segmentation, the "domain gap" (performance drop when moving to a new dataset) was remarkably low—only 1.32 when moving from MCU to JSRT, significantly lower than baseline models.
  • High Accuracy: On retinal vessel tasks, PASS achieved a cross-domain average Dice score of 85.30, even when trained on the small CHASE dataset.
  • Visual Clarity: As shown in the qualitative results, PASS produces cleaner edges and fewer "hallucinated" structures. It excels at capturing fine vessel details that other models often miss or blur.

Conclusion

By prioritizing global anatomical structure over local pixel intensities, PASS offers a robust solution for medical image segmentation that generalizes well across diverse clinical environments. While the model introduces additional training complexity due to its multi-discriminator setup, its ability to perform "out of the box" on unseen domains makes it a powerful tool for real-world clinical applications. Future work will explore extending this framework to 3D modalities like CT and MRI.

Summary updated