Production and Secondary Electron Yield Test of Amorphous Carbon Thin Film

Yuxin Zhang, Xiaoqin Ge, Siwei Wang, Yong Wang, Wei Wei, Bo ZhangJACOW 2018

Abstract

Amorphous carbon (a-C) thin film applied to vacuum chambers of high-energy particle accelerators can decrease secondary electron yield(SEY)and suppress electron-cloud effectively. A dc magnetron sputtering apparatus to obtain a-C film has been designed. With the equipment, a-C thin film can be deposited on the inner face of stainless steel pipes ultimately which is uniform and high-quality. Meanwhile, it is found that a-C has a low SEY<1.2 measured by the secondary electron emission measurement set-up in the National Synchrotron Radiation Laboratory. The result indicates that a-C is an ideal material for modern accelerators.
BibTeX
@inproceedings{zhang2018production,
  author = {Yuxin Zhang and Xiaoqin Ge and Siwei Wang and Yong Wang and Wei Wei and Bo Zhang},
  title = {{Production and Secondary Electron Yield Test of Amorphous Carbon Thin Film}},
  booktitle = {JACOW},
  year = {2018},
  doi = {10.18429/jacow-ipac2018-thpml128},
}

Loading related content...

Figure