Abstract
Accurate segmentation of tumors in 3D medical images is a critical yet challenging task due to high anatomical variability and ambiguous boundaries. We present PRISM (Promptable and Robust Interactive Segmentation Model), a framework that integrates human-in-the-loop interaction into 3D medical segmentation. By combining hybrid CNN-Transformer encoders with an iterative refinement loop and a dedicated corrective learning network, PRISM achieves near-human accuracy across diverse tumor datasets.
Introduction
Fully automated deep learning models, such as nnU-Net, often struggle with the low-contrast and variable nature of cancerous tissues in CT scans. While general-purpose interactive models like the Segment Anything Model (SAM) have emerged, they frequently fail in the medical domain due to the significant gap between natural and medical imagery. Furthermore, many existing models do not support effective iterative refinement, where a clinician can progressively "nudge" the model toward a perfect result. PRISM addresses these hurdles by providing a robust, multi-prompt interactive framework specifically tuned for 3D medical volumes.
Methods
PRISM is built upon four core architectural principles designed to maximize both local precision and global context:
- Hybrid Encoder Design: The model utilizes a dual-path encoder. A Convolutional Neural Network (CNN) captures fine-grained local textures and edges, while a Vision Transformer (ViT) processes the global context of the 3D volume.
- Iterative Interaction Loop: PRISM is designed for "human-in-the-loop" workflows. It accepts the segmentation from a previous step, merges it with new user prompts (points, boxes, or scribbles), and generates a refined mask.
- Confidence Learning: The decoder generates multiple mask candidates with associated confidence scores. An internal selector automatically chooses the highest-scoring candidate, enhancing reliability.
- Corrective Learning: A shallow refinement network specifically targets mislabeled voxels by analyzing the current error map and user prompts to polish final boundaries.
To train the model effectively, the authors employed a "sampler" that identifies false positives and negatives in real-time, generating synthetic correction prompts to teach the model how to respond to human feedback.
Results and Discussion
The researchers validated PRISM on four challenging 3D CT datasets: Colon, Pancreas, Liver, and Kidney tumors.
Quantitative Performance
PRISM significantly outperformed both fully automatic SOTA models and existing interactive variants. For instance, on the Colon tumor dataset, PRISM-ultra achieved a Dice score of 93.79%, a massive improvement over the fully automatic nnU-Net (43.91%) and the best-performing SAM variant (73.77%).
Monotonic Improvement
A key finding is PRISM's ability to achieve monotonic improvement. Unlike many models where additional prompts can sometimes confuse the AI, PRISM’s accuracy consistently increases, and its confidence intervals narrow as more information is provided by the user.
Conclusion
PRISM demonstrates that bringing the human back into the loop with specialized architectural support can bridge the gap between automated AI and clinical requirements. While challenges remain regarding the training complexity of scribble-based prompts and generalization to even broader datasets, PRISM sets a new benchmark for interactive 3D medical image segmentation.
Code Availability: The PRISM framework is publicly available at https://github.com/MedICL-VU/PRISM.
Summary updated