The PandaX-4T experiment, primarily designed for dark matter searches using a liquid xenon time projection chamber (TPC), has demonstrated its versatility as a high-precision tool for nuclear physics. By operating as a "5D calorimeter," the detector can simultaneously measure the energy, time, and three-dimensional position of individual radioactive decays. This capability has enabled the most precise measurement to date of the $^{216}$Po half-life, a fundamental parameter for understanding nuclear shell structures and astrophysical processes like the r-process.
The 5D Pairing Technique
The challenge in measuring short-lived isotopes like $^{216}$Po ($t_{1/2} \approx 0.14$ s) lies in distinguishing specific daughter decays from background noise in high-rate environments. The PandaX-4T collaboration addressed this by injecting a $^{228}$Th source to produce $^{220}$Rn gas within the detector. They then employed an "exact pairing" logic to link parent $^{220}$Rn decays to their subsequent $^{216}$Po daughter decays.
Tracking individual atoms: The 5D calorimeter allows researchers to follow the spatial displacement of Rn-Po pairs, even accounting for internal xenon convection.
To ensure high-purity pairing, three main criteria were applied:
Energy Matching: Events were required to match the characteristic alpha-particle energies of $^{220}$Rn (6.288 MeV) and $^{216}$Po (6.778 MeV).
Spatial Proximity: Accounting for the slight convection of liquid xenon (~3 mm/s), daughter decays had to occur within a tight spatial window (1.5 cm vertically and 5 cm horizontally) of the parent.
Temporal Window: The daughter decay was required to occur within 3 seconds of the parent event.
Results and Precision
Analyzing 35.4 hours of calibration data, the team identified 98,948 high-purity Rn-Po pairs from an initial pool of over 147,000 candidates. The resulting decay time distribution allowed for an exceptionally clean measurement of the $^{216}$Po half-life.
The measured decay time distribution of $^{216}$Po, yielding a half-life of $143.7 \pm 0.5$ ms.
The measured half-life is $143.7 \pm 0.5 \text{ (stat.)} \pm 0.2 \text{ (syst.)}$ ms. This result represents a significant improvement in precision, surpassing previous underground measurements by factors ranging from 5.6 to 20. The value is consistent with existing high-precision literature, validating the robustness of the 5D pairing method.
Conclusion and Future Outlook
This work underscores the potential of large-scale dark matter detectors to function as multi-purpose observatories. The ability to track individual atoms in 5D not only provides precise nuclear data but also offers a unique way to map internal fluid dynamics within the TPC. Future studies will extend this technique to other isotopes in the thorium decay chain, such as $^{212}$Bi and $^{208}$Tl, further refining our understanding of low-background environments and nuclear properties.
Summary updated
Abstract
We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes successive $α$ decays, first to $^{216}\rm Po$ and then to $^{212}\rm Pb$. PandaX-4T detector measures the 5-dimensional (5D) information of each decay, including time, energy, and 3-dimensional positions. Therefore, we can identify the $^{220}\rm Rn $ and $^{216}\rm Po$ decay events and pair them exactly to extract the lifetime of each $^{216}\rm Po$. With a large data set and high-precision $^{220}\rm $Rn-$^{216}\rm $Po pairing technique, we measure the $^{216}\rm Po$ half-life to be $143.7\pm0.5$ ms, which is the most precise result to date and agrees with previously published values. The leading precision of this measurement demonstrates the power of 5D calorimeter and the potential of exact parent-daughter pairing in the xenon TPC.
BibTeX
@misc{collaboration2025precise,
author = {PandaX Collaboration and Chenxiang Li and Zihao Bo and Wei Chen and Xun Chen and Yunhua Chen and Cheng Chen and Xiangyi Cui and Min Deng and Yingjie 英杰 Fan 樊 and Deqing Fang and Xin Fu and Zhixing Gao and Yanqi Ge and Lisheng Geng and Karl Giboni and Xunan Guo and Xuyuan Guo and Zichao Guo and Chencheng Han and Ke Han and Changda He and Jinrong He and Houqi Huang and J. Huang and Yule Huang and Ruquan Hou and Xiangdong Ji and Yonglin Ju and Xianyong Lan and Jiafu Li and Mingchuan Li and Peiyuan Li and Shuaijie Li and Tao Li and Yangdong Li and Zhiyuan Li and Qing Lin and Jianglai Liu and Yuanchun Liu and Congcong Lu and Xiaoying Lü and Lingyin Luo and Yunyang Luo and Y. G. and Yajun Mao and Meng Yue and Binyu Pang and Ningchun Qi and Zhicheng Qian and Xin Shan and Xiaofeng Shang and Xiyuan Shao and Guofang Shen and Manbin Shen and Wenliang Sun and Xuyan Sun and Tao Yi and Yueqiang Tian and Yuxin Tian and Anqing Wang and Guanbo Wang and Hao Wang and H. Wang and Jiamin Wang and Lei Wang and M. Wang and Qiuhong Wang and Shaobo Wang and Shibo Wang and Siguang Wang and Wei Wang and Wang Xu and Weijia Zhou and Y. Wei and Weihao Wu and Yuan Wu and Mengjiao Xiao and Xiang Xiao and Kaizhi Xiong and Jianqin Xu and Yunhua Xu and Shunyu Yao and Binbin Yan and Xiyu Yan and Yong Yang and Peihua Ye and Chunxu Yu and Ying Yuan and Zhe Yuan and Youhui Yun and Xinning Zeng and Minzhen Zhang and Peng Zhang and Shibo Zhang and Siyuan Zhang and Shu Zhang and Tao Zhang and Wei Zhang and Yang Zhang},
title = {{Precise Measurement of $^\{216\}$Po Half-life with Exact Parent-daughter Pairing in PandaX-4T}},
year = {2025},
eprint = {2507.13241},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2507.13241},
howpublished = {arXiv},
}