P422: Validation of a digital FISH analysis workflow in an academic reference laboratory*
Abstract
Introduction: Cytogenetics and pathology laboratories performing interphase suspension FISH face increasing challenges as workforce shortages continue and needs to accommodate remote work increase.Implementation of digital FISH workflows provides many potential benefits for clinical laboratories, including automation, quality improvement, scalability, time and cost savings, reduced space needs, and workforce flexibility.However, there are also many notable barriers.Challenges to building a reliable, adaptable system for a broadening test menu include the learning curve of a new analysis workflow, scalability for large volume testing, workflow standardization, and data storage needs.Here, we present results from validation of a digital FISH analysis workflow within a large academic reference laboratory.Methods: Following wet lab processing, FISH slides accommodating up to eight separate hybridizations (BioDot slides) are loaded onto the Applied Spectral Imaging HI-FISH automated image capture system.Validation of the digital analysis workflow evolved throughout the project, using the manual analysis workflow as the baseline.Image analysis using both 3D and merged (flattened) images from Z-stacks have been evaluated.Quality for digital analysis was established by scanning slides after manual scoring using internally established criteria for probe signal intensity and background.Analysis times were measured and compared on the same slides between the manual and digital methods.A total of 9 probes with locus-specific, centromere, break apart, and dual fusion designs have been fully validated for digital FISH use on hematologic specimens.Reference ranges, accuracy, precision, analytical sensitivity, and analytical specificity were established using similar requirements to manual FISH validations.Analytical sensitivity was established by the reference range, and precision was within established guidelines of <5% difference for normal and <15% for abnormal cases.Per probe preset exposure times were empirically determined during the validation.Later, a dynamic exposure setting was validated using the preset as the baseline, allowing for better standardization of image quality.A minimum of 400 and 300 cells, respectively, were captured per probe for assays requiring 200 or 100 cell counts to ensure third scorer capabilities.Analysis was performed using a blinded two-scorer method similar to manual analysis, with final data compilation performed by a senior technologist prior to director review.Results: Use of the digital analysis workflow showed no differences in quality as compared to the manual analysis method, but time studies indicated that the image analysis process is much slower, with a 70%-time increase as compared to manual scoring using the two-scorer method.The digital workflow's use of cell-by-cell scoring is a notable change from the process at the manual microscope and may benefit from additional optimization and training.Validation of FISH probes on the digital system showed generally higher reference range cut-offs (average increase of 1.5% across 9 probes), which may represent bias from the new workflow, since cells are presented individually and must be consciously scored or skipped.Digital FISH probe accuracy and analytical specificity had 100% concordance with manual FISH.Comparison of 3D vs merged (referred to in the manufacturer's software as "Z-stacked") images in the digital analysis workflow showed no differences in overall quality, but improved image scan times (18%) and storage capabilities (38%) were observed with use of the Z-stacked images.Conclusion: Compared to the manual method, quality of the digital workflow is comparable and has been established across a variety of probe types and image capture/analysis configurations.Challenges to complete digital conversion include large time commitments for validation and user training, low-cellularity cases, and workflow optimization.Time studies have indicated more development work is needed for speed equivalency or gains; this may require further evaluation and investment in computational, IT, and data storage needs, as well as alternative modes of image analysis including automation/AI-assistance.
BibTeX
@inproceedings{longhurst2023p,
author = {Maria Longhurst and Emily Aston and Jodi Zockle and Wenhua Zhou and Leslie R. Rowe and Kimberly Frizzell and E. D. Fredrickson and Kathryn O'Brien and Marshall Priest and Chantry J. Clark and Bo Hong and Erica Andersen},
title = {{P422: Validation of a digital FISH analysis workflow in an academic reference laboratory*}},
booktitle = {Genetics},
year = {2023},
doi = {10.1016/j.gimo.2023.100469},
}Ask Althea to put this paper to the test.
Loading related content...