Abstract
Most MRI liver segmentation methods use a structural 3D scan as input, such as a T1 or T2 weighted scan. Segmentation performance may be improved by utilizing both structural and functional information, as contained in dynamic contrast enhanced (DCE) MR series. This study investigates the optimal input configuration of DCE-MR images for convolutional neural networks (CNNs). Three configurations were evaluated: (I) a single phase image, (II) separate phases as separate inputs (late fusion), and (III) separate phases as channels of one input image (early fusion). These were tested using a dilated fully convolutional network and a small U-net. Results indicate that treating separate phases as channels (Configuration III) yields superior performance, with no significant difference found between the two network architectures under this optimal configuration.
Introduction
Liver segmentation is a foundational step in diagnosing and treating liver lesions. While most automated methods rely on static 3D scans, Dynamic Contrast Enhanced (DCE) MRI provides a wealth of additional information by capturing images at different stages of contrast agent distribution—from the arterial phase to the equilibrium phase. This allows clinicians to observe both the anatomy and the functional behavior of the liver.
The primary challenge addressed in this research is determining how a CNN should process this multi-dimensional data. Options include selecting a single "best" phase, processing phases independently and combining results later, or stacking them as input channels.
Methods
The study compared two CNN architectures across three distinct input configurations using DCE-MRI series from 38 patients.
Network Architectures
- Dilated Fully Convolutional Network (FCN): A 7-layer network utilizing dilated convolutions to expand the receptive field while maintaining spatial resolution.
- Modified U-Net: A compact version of the standard U-Net architecture, tailored for the $256 \times 256$ voxel size of the dataset.
Input Configurations
- Config I (Single Phase): Only the "late arterial phase" was used, as it typically offers the best visual contrast.
- Config II (Late Fusion): Six phases were processed individually, with feature maps concatenated near the network's end.
- Config III (Early Fusion/Channels): All six phases were treated as different channels of a single input image, analogous to how a computer treats Red, Green, and Blue channels.
Dataset and Preprocessing
The dataset consisted of 38 series (19 for training/validation, 19 for testing). Images underwent motion correction via PCA-based registration and were normalized using zero-mean-unit-variance rescaling. Ground truth was established through manual annotations verified by an experienced radiologist.
Results and Discussion
Performance was evaluated using the Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD).
Key Findings
- Optimal Configuration: Configuration III (Channels) was the clear winner for both architectures. This suggests that allowing the network to learn relationships between raw intensities across phases before abstraction is highly beneficial.
- Architecture vs. Configuration: When using the optimal "Channels" configuration, no significant performance difference was observed between the Dilated FCN and the U-Net. This indicates that data formatting may be as critical as architectural choice.
- Late Fusion Limitations: Configuration II performed poorly, likely because shared weights across phases prevented the network from optimizing for the unique characteristics of individual contrast phases.
Qualitative Observations
Visual analysis showed that the Dilated FCN tended toward oversegmentation (including non-liver tissue), while the U-Net tended toward undersegmentation (missing parts of the liver). Despite these tendencies, the CNNs using Configuration III approached human-level consistency (median human DSC of 0.943).
Conclusion
This study demonstrates that the "Channels" input configuration is the most effective method for incorporating multi-phase DCE-MRI data into CNNs for liver segmentation. While the current 2D implementation shows promise, future work involving 3D convolutions and larger datasets could further enhance spatial consistency and segmentation accuracy.
Summary updated