OP10.03: Fetal femur volume measurement using fusion of multiple three‐dimensional ultrasound image sets: a pilot study
Abstract
The ultrasonographic appearance of fetal bone is compromised by posterior acoustic shadowing. Even though the femoral volume can be measured using 3D ultrasound, it is possible that part of the femur is hidden into its own acoustic shadow. Our objective was to obtain a composite femoral view by fusing together multiple 3D image sets of the same femur, taken from different angles. We tested the hypothesis that femoral volume measured on such a fused view may be different than the one measured on a standard single view. We also assessed the impact of image fusion on the reproducibility measures for femur volumetry. Scans from 25 healthy singleton pregnancies were included. Six static 3D scans of each femur were obtained from different angles. These image sets were merged using image registration and fusion, an offline image analysis technique. Femur volume measurements were performed both on the standard and fused volumes using the multiplanar method, by two observers. Distributions of volume measurements were compared using t-test for paired samples. In addition, intra and inter-observer repeatability were assessed using Bland-Altman plots and within subject coefficients of variation (CV). Volume fusion was successful in 24 out of 25 cases, with a median of 4 merged views per fusion (range 2–6). The measured femoral volume on fused views was significantly higher compared with standard views (mean volume = 1.7 ml vs. 1.3 ml respectively, P < 0.0001). Improved intraobserver and interobserver reproducibility of femoral volumetry was demonstrated on fused views compared with standard views: the CV of paired measurements by the same observer decreased from 5.8% for the standard views to 4.6% for fused. Similarly, in paired measurements by two different observers, the CV decreased from 10.0% to 4.9%. Fusion of multiple 3D scans of the fetal femur results in higher femoral volume measurements and superior reproducibility. Whether this higher volume is reflective of actual femoral volume is unclear.
BibTeX
@inproceedings{ioannou2010op,
author = {C. Ioannou and Mohammad Yaqub and J. Alison Noble and M K Javaid and Aris T. Papageorghiou},
title = {{OP10.03: Fetal femur volume measurement using fusion of multiple three‐dimensional ultrasound image sets: a pilot study}},
booktitle = {Ultrasound},
year = {2010},
doi = {10.1002/uog.8014},
}Ask Althea to put this paper to the test.
Loading related content...