On Biases in a UK Biobank-Based Retinal Image Classification Model

Anissa Alloula, Rima Mustafa, Daniel R. McGowan, Bartlomiej W. Papiez

Introduction

Machine Learning (ML) models in healthcare often suffer from "hidden" biases, where high average accuracy masks poor performance for specific subgroups. This raises critical safety and equity concerns, potentially leading to underdiagnosis in vulnerable populations. While bias has been explored in other medical imaging domains, retinal imaging—a non-invasive "window" into systemic health—remains under-studied. This research specifically examines whether such disparities persist in the UK Biobank (UKBB), a dataset renowned for its rigorous, standardized data collection protocols. If bias exists here, it suggests that standardizing hardware and protocols is insufficient to guarantee fairness.

Methods

The study utilized 80,966 fundus retinal images from 78,346 individuals in the UKBB to classify hypertension, defined by blood pressure readings and medication use. All images were captured using identical OCT scanner models, representing a "best-case scenario" for data consistency. A baseline model was developed using the InceptionV3 architecture.

To address observed biases, the researchers tested a suite of mitigation strategies across three stages of the ML pipeline:

  • Pre-processing: Resampling minority subgroups to balance training data.
  • In-processing: Algorithmic approaches including GroupDRO (minimizing worst-group loss), Domain-Independent learning (group-specific classification layers), and SWAD (Stochastic Weight Averaging Densely).
  • Post-processing: Subgroup-specific recalibration of decision thresholds.

Results

The baseline model achieved an overall AUC of 71% and 73% accuracy. However, significant performance gaps emerged across various subgroups. Notably, a 15% AUC gap was observed between age groups, and a surprising 10% gap existed between different assessment centers despite the use of standardized equipment and protocols.

Mean Subgroup AUC for the baseline model across various demographic and clinical categories.

Analysis using Principal Component Analysis (PCA) on the model’s internal representations revealed that images from the worst-performing center (Center 'f') were mathematical outliers. The model detected subtle variations in these images that were invisible to standard human quality controls. Furthermore, the performance gap widened significantly on unseen test data, suggesting a failure to generalize learning equally across groups.

The evaluation of mitigation strategies highlighted a significant "fairness trade-off." Most methods improved fairness by "leveling down"—reducing overall performance to narrow the gap, rather than lifting the performance of disadvantaged groups.

Overall AUC vs. Min AUC for various bias mitigation models targeting Age and Centre disparities.

As shown in the figure above, while some methods like DomainInd reduced the age-related gap, they often did so at the cost of overall accuracy. SWAD was the only method that maintained overall performance, but it failed to significantly close the fairness gaps, particularly for age-based disparities.

Discussion

The findings suggest that standardizing hardware and protocols is insufficient to guarantee fairness in medical AI. The "assessment center" bias indicates that models can be sensitive to environmental or procedural factors that are not immediately apparent. Generic fairness algorithms often fail to provide a "one-size-fits-all" solution without degrading overall model utility. Future work must focus on characterizing the root causes of these biases—whether biological, technical, or procedural—to develop more effective, targeted mitigation strategies.

Summary updated