Abstract
OESense is a novel sensing system that repurposes standard earbuds into high-fidelity motion sensors by leveraging the acoustic occlusion effect. By utilizing an inward-facing microphone to capture bone-conducted vibrations, OESense enables robust activity recognition and facial gesture detection that is immune to environmental noise and head-motion artifacts.
Introduction
Wearable ear-based devices, or "earables," typically rely on Inertial Measurement Units (IMUs) or external microphones for motion and activity tracking. However, IMUs often fail to detect subtle motions like chewing and are prone to artifacts from simple head movements. External microphones, conversely, are easily overwhelmed by ambient noise. OESense addresses these limitations by exploiting the occlusion effect—the amplification of low-frequency bone-conducted sounds when the ear canal is sealed.
The Occlusion Effect and System Design
The core of OESense lies in the physics of the ear canal. When occluded by an earbud, vibrations traveling through the skull are trapped, resulting in a significant boost in low-frequency sound pressure levels (up to 40 dB below 1000 Hz).
The hardware prototype consists of commercial earbuds modified with an internal MEMS microphone facing the eardrum. To ensure the system functions correctly, a software-based "fit test" uses dual-tone acoustic probes (300 Hz and 1500 Hz) to verify a proper physical seal.
Signal Processing and Robustness
OESense distinguishes human-induced vibrations from audio content through frequency multiplexing. Most physical activities generate signals below 50 Hz, whereas music and speech typically occupy frequencies above 100 Hz. By applying a 50 Hz low-pass filter, the system can extract clean motion data even during loud audio playback.
Furthermore, the sealed ear canal acts as a natural acoustic barrier, physically suppressing high-frequency environmental noise like wind or traffic, which would otherwise saturate an external microphone.
Evaluation and Results
The system was evaluated with 31 subjects across various tasks:
- Step Counting: Achieved 99.3% recall, outperforming standard industrial pedometers.
- Activity Recognition: Identified five activities (walking, running, still, chewing, drinking) with 98.3% recall using binaural data fusion.
- Facial Gestures: Detected taps on different facial regions with 97.0% recall, effectively turning the face into a touch interface.
The system maintains a low latency of 40.85 ms, supporting real-time interaction. While highly accurate, performance for gesture recognition is enhanced by a brief (1-minute) personalization phase to account for individual anatomical differences.
Discussion and Conclusion
OESense demonstrates that the occlusion effect, often considered a nuisance in audio engineering, can be a powerful modality for human sensing. By focusing on low-frequency bone conduction, it achieves a level of robustness and sensitivity unattainable by traditional IMU or external mic-based systems. Future work will focus on reducing the power consumption of the prototype and investigating the impact of medical conditions, such as earwax buildup, on signal quality.
Summary updated