No Faults in Structure? How to Diagnose Hidden Interactions

Claudia Böttcher

Introduction

Model-based diagnosis (MBD) has long been a cornerstone of automated troubleshooting. However, traditional MBD systems typically operate under a "closed-world" assumption: they assume the system's physical structure perfectly matches its original blueprint. In reality, systems often develop structural faults—unintended interactions such as a leak between two isolated tanks or a solder bridge between circuit pins. When these occur, standard diagnostic engines often fail, misinterpreting a single structural change as multiple simultaneous component failures.

This paper introduces HiDe&Seek (Hidden Interaction Detection), a framework designed to identify these elusive structural faults by combining behavioral analysis with spatial reasoning.

The HiDe&Seek Framework

HiDe&Seek treats the system model as a dynamic entity. Instead of modeling every possible unintended connection upfront—which would lead to a combinatorial explosion—the system only investigates hidden interactions when observations cannot be explained by simple component malfunctions.

The framework relies on several key components:

  1. Hidden Interaction Models: Specialized templates that link physical configurations (e.g., proximity) to specific behavioral impacts (e.g., an unintended flow).
  2. Triggered Hypothesis Generation: The search for structural faults is only activated when the system is forced to consider complex multiple-fault diagnoses that match known interaction patterns.
  3. Spatial Reasoning: Using a tool called "Space-box," the system verifies if suspect components are physically positioned to interact (e.g., checking qualitative relations like "on-top-of").
  4. Runtime Model Refinement: If a hidden interaction is plausible, the system modifies its internal description on the fly to test if this new connection explains the observed discrepancies.

Case Study: The Ballast Tank System

The primary proof-of-concept for HiDe&Seek is a ballast tank system, commonly used in offshore plants to maintain stability. In a typical scenario, a leak might develop between two tanks that are supposed to be isolated.

The ballast tank system showing a hidden interaction between Tank 2 and Tank 3.

As shown in Figure 1, a hidden interaction between Tank 2 and Tank 3 can cause confusing sensor readings. A traditional MBD system might report that Tank 2 is losing water while Tank 3 is simultaneously gaining water, suggesting two independent failures. HiDe&Seek, however, recognizes this pattern and uses spatial data to hypothesize a single structural leak between the two adjacent tanks.

Modeling Component Behavior

To diagnose these faults, the system must first understand the nominal behavior of individual components. HiDe&Seek uses qualitative and quantitative equations to define how components like pipes and tanks should function.

Behavioral model of an ascending pipe, defining the relationship between pressure, flow, and physical dimensions.

For example, Figure 3 illustrates the behavioral model for an ascending pipe. By defining the relationship between base pressure ($P_{base}$), top pressure ($P_{top}$), flow ($i$), and pipe height ($b$), the diagnostic engine can detect when observed pressures deviate from the expected values, triggering the search for a root cause—whether it be a simple blockage or a complex hidden interaction.

Key Insights and Results

The authors demonstrate that by following the "law of parsimony"—the principle that a single cause is more likely than multiple independent ones—HiDe&Seek can simplify complex diagnostic problems.

Key results include:

  • Qualitative Accuracy: In the ballast tank example, the system successfully identified a single leak as the cause of multiple sensor discrepancies.
  • Domain Generality: The framework proved capable of handling diverse domains, from fluid dynamics in tanks to electronic "bridge faults" in circuits, by using generalized interaction templates.
  • Efficiency: By only activating interaction models when needed, the system manages computational complexity effectively, as proven by its implementation on a SUN Sparc workstation.

Limitations and Future Work

While HiDe&Seek excels at identifying internal structural faults, it currently struggles with interactions involving the external environment (e.g., a leak to the outside world). Future research aims to expand the library of interaction models and better characterize the specific classes of applications where structural faults are most likely to manifest as "apparently unrelated" behavioral discrepancies.

Summary updated