NeuroQA: A Large-Scale Image-Grounded Benchmark for 3D Brain MRI Understanding

Mohammad H. Abbasi, Favour Nerrise, Shaurnav Ghosh, Ridvan Yesiloglu, Yuncong Mao, Bailey Trang, Mohammad Asadi, Merryn Daniel, Gustavo Chau Loo Kung, Ken Chang, Pavan Pinkesh Shah, Adam Turnbull, Kyan Younes, Seena Dehkharghani, Ehsan AdeliarXiv 2026 · arXiv

TL;DR

NeuroQA is a massive new benchmark of 57,000+ QA pairs designed to evaluate how well AI models actually understand 3D brain MRIs. By rigorously auditing for "text-only shortcuts," the authors reveal a sobering reality: current state-of-the-art vision-language models (VLMs) fail to outperform simple text-only baselines, highlighting a major gap in 3D medical image reasoning.

What Problem Does This Paper Address?

While Vision-Language Models (VLMs) like GPT-4 and Gemini are being touted as potential clinical assistants, evaluating them on medical images is notoriously difficult. Most existing benchmarks focus on 2D slices (like chest X-rays) or rely on narrow diagnostic labels.

More importantly, many medical VQA benchmarks suffer from "shortcut exploitation." Because certain clinical conditions are highly correlated with specific demographics or question phrasing, models can often "guess" the correct answer from the text alone without ever looking at the image. Prior studies have shown that some models retain up to 99% of their accuracy even when the image is removed. NeuroQA addresses these gaps by providing a large-scale, 3D-native benchmark that is specifically engineered to resist these text-only shortcuts.

Methods

The authors developed a five-stage deterministic pipeline to transform raw neuroimaging data into validated QA pairs. Notably, they avoided using LLMs for generation to prevent hallucinations, relying instead on a 38-rule deterministic audit.

The NeuroQA construction pipeline involves five stages of generation, expert review, and shortcut elimination.

Key methodological innovations include:

  • 3D-Native Reasoning: Unlike 2D benchmarks, NeuroQA pairs questions with full 3D volumes, requiring models to integrate information across axial, sagittal, and coronal planes.
  • Image-Grounded vs. Image-Informed: The benchmark splits questions into those answerable by visual inspection (grounded) and those derived from quantitative metadata like exact volumetric measurements (informed).
  • Shortcut Refinement: The authors balanced answer distributions (e.g., ensuring a 50/50 Yes/No split per template) to force models to rely on the image. This reduced text-only accuracy from over 80% to just 44.6%.
  • Image-Grounding Protocol: A new evaluation suite that uses "stress tests"—like withholding the image or checking for hallucinations—to certify if a model is truly "grounded" in the visual data.

Datasets

NeuroQA aggregates 56,953 QA pairs from 12,977 subjects across 12 diverse neuroimaging datasets (including ADNI, ABCD, PPMI, and BraTS). It covers a wide lifespan (ages 5–104) and five clinical domains: Alzheimer’s, Parkinson’s, tumors, white matter disease, and neurodevelopment.

Table 1: Comparison with prior medical VQA benchmarks. Formats: answer types (1 = Open, 2 = YN + Open, 3 = YN + MCQ + Open). Audit: dataset-level validation on frozen data (Clinical = clinician rater study, Shortcut = template-level shortcut audit). ∗3D scans evaluated on representative 2D slices. †Filtered from 2.7M candidates. ⋄Released as an evaluation set, not as a public benchmark resource.

The release follows a two-tier architecture:

  1. Tier 1 (Public): Direct access to ~19k QA pairs from open-access datasets.
  2. Tier 2 (DUA): Reproducible scripts for ~37k pairs from datasets requiring Data Use Agreements.

Key Insights and Ideas

  • The "Shortcut Floor": The most striking finding is that the "text-only" baseline (which just predicts the majority answer for a question template) achieves 49.4% accuracy. Currently, no VLM tested exceeds this floor.
  • The Perceptual Ceiling: Clinician evaluations showed that humans excel at "grounded" tasks (like identifying the MRI modality) but struggle with "informed" tasks (like estimating if a hippocampus is exactly below the population median). This suggests a natural ceiling for what can be recovered by visual inspection alone.
  • Image Input Can Be Distracting: For some models, adding the image actually decreased performance compared to text-only prompts, suggesting that the visual features may be introducing noise rather than useful signal for these architectures.

Key Results

The benchmark reveals a significant performance gap between AI and human experts. While clinicians achieved a mean of 48.9% (limited by the "informed" categories), they were nearly perfect on basic visual tasks.

Table 2: Baselines on NEUROQA test-public (N=5,524; Nclosed=4,454). Only the best model per VLM family is shown; full per-model results in Fig. 3 and Tables 21–23. Clinician evaluation is on a 100-item subset (Cohen’s κ = 0.40). Random: analytical chance floor. Text-only: majority answer per template (digits stripped), no image; closed accuracy defines the shortcut floor (49.4%). ∆: closed accuracy minus text-only floor. SS (Shortcut Score): 1 −Closed−49.4
  • Best VLM: Gemini-3.1-Pro reached 47.5% closed-format accuracy.
  • Supervised Baseline: A 3D CNN trained specifically on this data reached 43.7%.
  • Shortcut Margin: NeuroQA boasts a shortcut margin of only +5.1 percentage points above random chance, making it the most "shortcut-resistant" medical VQA benchmark to date.

Limitations and Future Work

The authors acknowledge several scope limits:

  • Modality Constraints: White matter hyperintensity items currently use T1-weighted images, even though T2/FLAIR is clinically preferred.
  • Human-Assessable Gap: Some "Measurement" items require volumetric precision that no human (and currently no VLM) can achieve by eye.
  • Future Directions: The team plans to expand into multimodal inputs (T2/FLAIR), conduct larger studies with board-certified radiologists, and introduce longitudinal sub-tracks for reasoning across multiple time points.

NeuroQA sets a rigorous new standard for medical AI, suggesting that before we trust VLMs with clinical decisions, they first need to learn how to actually "see" in 3D.

Summary updated

Abstract

We present NeuroQA, a large-scale benchmark for visual question answering in 3D brain magnetic resonance imaging (MRI), with 56,953 QA pairs from 12,977 subjects across 12 datasets. It spans ages 5-104 and five clinical domains: Alzheimer's, Parkinson's, tumors, white matter disease, and neurodevelopment. Unlike prior medical Visual Question Answering (VQA) efforts that operate on 2D slices or rely on narrow diagnostic labels, NeuroQA pairs every item with a full 3D volume. It evaluates 11 clinically grounded reasoning skills across Yes/No, multiple-choice, and open-ended formats. Of the 203 templates, 131 are image-grounded (answerable from a 3-plane viewer) and 72 are image-informed (ground truth from quantitative volumetry or clinical instruments). To remove text-only shortcuts, we apply answer-distribution refinement, reducing closed-format text-only accuracy from $>$80% to 44.6%; image necessity is assessed separately through an image-grounding protocol released with the benchmark. A 38-rule deterministic pipeline and two rounds of expert review verify every QA pair against FreeSurfer measurements, metadata, or radiology report fields, with zero same-subject contradictions across templates. We conduct a clinician evaluation in which two clinicians independently assess 100 frozen test items on a three-plane viewer. On closed-format (Yes/No + multiple-choice) test-public items, the best zero-shot vision-language model and a supervised 3D CNN baseline reach 47.5% and 43.7% accuracy respectively, both below the 49.4% text-only majority-template floor. NeuroQA adopts a two-tier release with public QA pairs for open-access datasets and reproducible generation scripts for datasets restricted by data use agreements (DUAs), plus subject-level splits, a held-out private test set, and an online leaderboard.
BibTeX
@misc{abbasi2026neuroqa,
  author = {Mohammad H. Abbasi and Favour Nerrise and Shaurnav Ghosh and Ridvan Yesiloglu and Yuncong Mao and Bailey Trang and Mohammad Asadi and Merryn Daniel and Gustavo Chau Loo Kung and Ken Chang and Pavan Pinkesh Shah and Adam Turnbull and Kyan Younes and Seena Dehkharghani and Ehsan Adeli},
  title = {{NeuroQA: A Large-Scale Image-Grounded Benchmark for 3D Brain MRI Understanding}},
  year = {2026},
  eprint = {2605.20525},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2605.20525},
}

Loading related content...