Motoneuron-driven computational muscle modelling with motor unit resolution and subject-specific musculoskeletal anatomy

Arnault H. Caillet, Andrew T. M. Phillips, Dario Farina, Luca Modenese

Abstract

The computational simulation of human voluntary muscle contraction is possible with EMG-driven Hill-type models of whole muscles. Despite impactful applications in numerous fields, the neuromechanical information and the physiological accuracy such models provide remain limited because of multiscale simplifications that limit comprehensive description of muscle internal dynamics during contraction. We addressed this limitation by developing a novel motoneuron-driven neuromuscular model, that describes the force-generating dynamics of a population of individual motor units, each of which was described with a Hill-type actuator and controlled by a dedicated experimentally derived motoneuronal control. In forward simulation of human voluntary muscle contraction, the model transforms a vector of motoneuron spike trains decoded from high-density EMG signals into a vector of motor unit forces that sum into the predicted whole muscle force. The control of motoneurons provides comprehensive and separate descriptions of the dynamics of motor unit recruitment and discharge and decode the subject’s intention. The neuromuscular model is subject-specific, muscle-specific, includes an advanced and physiological description of motor unit activation dynamics, and is validated against an experimental muscle force. Accurate force predictions were obtained when the vector of experimental neural controls was representative of the discharge activity of the complete motor unit pool. This was achieved with large and dense grids of EMG electrodes during medium-force contractions or with computational methods that physiologically estimate the discharge activity of the motor units that were not identified experimentally. This neuromuscular model advances the state-of-the-art of neuromuscular modelling, bringing together the fields of motor control and musculoskeletal modelling, and finding applications in neuromuscular control and human-machine interfacing research.

Introduction

For decades, the standard approach to simulating human muscle contraction has relied on "lumped" Hill-type models. These models typically transform a single electromyographic (EMG) signal into a single force output, treating the entire muscle as a "black box." However, this is a significant oversimplification. In reality, a muscle is a population of hundreds of motor units (MUs)—each consisting of a single motoneuron and the muscle fibers it innervates. The central nervous system controls force by varying which units are active (recruitment) and their firing rates (rate coding).

Traditional models lose this physiological detail, which is critical for advanced neurorehabilitation and high-fidelity human-machine interfaces. This research bridges the gap between motor control (the "software" of the nervous system) and musculoskeletal modeling (the "hardware" of the body) by developing a first-of-its-kind neuromuscular model that simulates force through individual motor unit dynamics.

The Neuromuscular Modeling Pipeline

The researchers developed a multi-stage pipeline to create a motoneuron-driven model with motor unit resolution, integrating neural decoding with subject-specific anatomy.

Overview of the motoneuron-driven neuromuscular modeling pipeline, from neural decoding to force validation.

The pipeline consists of four primary components:

  1. Neural Decoding: High-density EMG (HDEMG) signals were recorded using a 256-electrode grid on the Tibialis Anterior. Blind-source separation algorithms were used to "unmix" these signals and identify individual motoneuron spike trains.
  2. Motor Unit Pool Reconstruction: Because electrodes cannot capture every neuron, a computational method was employed to estimate the activity of the entire pool (400 units) based on the experimental sample.
  3. Subject-Specific Anatomy: MRI scans were used to build a personalized 3D musculoskeletal model in OpenSim, ensuring the mechanical "levers" matched the participant's actual anatomy.
  4. Cascading MU Model: Each of the 400 motor units was modeled as an individual Hill-type actuator. The model simulates the physiological chain of events: neural impulses trigger action potentials, calcium release, and cross-bridge formation to generate force.

Key Results and Insights

The model demonstrated high accuracy in predicting muscle force, particularly when the neural control was representative of the entire motor unit pool.

  • Predictive Accuracy: At 30% of maximum voluntary contraction (MVC), the model achieved a normalized Root-Mean-Square Error (nRMSE) as low as 5.3% and a coefficient of determination ($r^2$) of 0.98.
  • Representativeness and Density: Force predictions improved significantly with higher electrode density (256 vs. 64 or 36 electrodes). The model's performance depends heavily on how well the recorded motoneurons represent the whole pool.
  • Synthetic Completion: The study showed that even with a limited sample of identified motor units, mathematical "reconstruction" of the full pool's activity allows for accurate force estimation, especially during the recruitment (ramp-up) phase.
  • Physiological Fidelity: The model successfully captured the "onion skin" effect, where early-recruited, low-threshold motor units maintain higher firing rates than later-recruited ones, a key feature of smooth force production.

Limitations and Future Directions

While a significant advancement, several challenges remain for clinical or real-time application:

  • Computational Complexity: The current model is too slow for real-time control of neuroprosthetics.
  • Dynamic Tasks: The validation was limited to isometric (static) contractions. Moving limbs introduce motion artifacts that complicate HDEMG decoding.
  • Mechanical Simplifications: A "rigid tendon" was assumed for the Tibialis Anterior; more compliant muscles would require modeling the interaction between fibers and stretchy tendons.

Future work will focus on optimizing computational speed and extending decoding algorithms to handle dynamic movements like walking or reaching, potentially revolutionizing human-machine interfacing.

Summary updated

BibTeX
@article{caillet2023motoneuron,
  author = {Arnault H. Caillet and Andrew T. M. Phillips and Dario Farina and Luca Modenese},
  title = {{Motoneuron-driven computational muscle modelling with motor unit resolution and subject-specific musculoskeletal anatomy}},
  journal = {PLOS Computational Biology},
  year = {2023},
  doi = {10.1371/journal.pcbi.1011606},
}
Figure