Introduction
Digital Subtraction Angiography (DSA) is the clinical gold standard for visualizing vascular structures to diagnose conditions like strokes and aneurysms. However, capturing high-frame-rate sequences to visualize dynamic blood flow involves significant X-ray radiation exposure. Reducing the capture frequency can lower the dose but results in jerky, low-temporal-resolution sequences that hinder diagnosis.
Video Frame Interpolation (VFI) offers a potential solution by synthesizing intermediate frames. However, general-purpose VFI models often fail on DSA data due to the complex, non-rigid motion of contrast agents and the high density of fine vascular structures, leading to "structural dissipation" where small vessels disappear or blur.
Methodology: The MoSt-DSA Framework
To address these medical-specific challenges, the researchers developed MoSt-DSA (Motion and Structural interactions for DSA). The architecture is built around the Motion-Structure Feature Extractor (MSFE), which explicitly models the interplay between static anatomy and dynamic flow.
Efficient MoSt Attention
A core innovation is the MoSt Attention mechanism. Traditional self-attention mechanisms have quadratic computational complexity, making them memory-intensive for high-resolution medical images. MoSt-DSA utilizes Lambda Layers to implement linear-complexity attention. This allows the model to capture fine-grained structural details and complex motion trajectories with significantly lower VRAM usage and higher inference speeds.
Direct Multi-Frame Synthesis
Unlike recursive interpolation models that must be run multiple times to generate a sequence of frames, MoSt-DSA is a direct multi-frame interpolator. It can generate any number of intermediate frames at specific time steps ($t$) in a single forward pass, ensuring temporal consistency and operational efficiency.
Experimental Results and Clinical Impact
The model was validated using a large-scale dataset of 470 head DSA sequences collected from eight different hospitals. MoSt-DSA establishes a new state-of-the-art for medical frame interpolation.
Accuracy and Efficiency
As shown in the performance analysis, MoSt-DSA outperforms top-tier general models such as FILM and EMA-VFI in both accuracy and efficiency. It achieves an average SSIM of over 0.93 and a PSNR over 38. Crucially, the model is highly efficient, utilizing approximately 2.61G of VRAM and achieving an inference time of ~0.024s per frame.
Radiation Reduction
By successfully interpolating 1, 2, or 3 frames between actual captures, the MoSt-DSA framework can theoretically reduce patient radiation doses by 50%, 67%, and 75%, respectively, while maintaining the diagnostic clarity required for interventional surgery.
Conclusion
MoSt-DSA demonstrates that specialized architectural choices—specifically modeling motion-structure interactions and utilizing linear-complexity attention—can overcome the limitations of general AI models in medical imaging. By providing high-fidelity temporal reconstruction at low computational costs, MoSt-DSA offers a viable path toward safer, low-dose clinical angiography. Future research will focus on expanding the model's application to other anatomical regions and integrating it directly into interventional X-ray hardware.
Summary updated