MidRISH: Unbiased harmonization of rotationally invariant harmonics of the diffusion signal

Nancy R. Newlin, Michael E. Kim, Praitayini Kanakaraj, Tianyuan Yao, Timothy J. Hohman, Kimberly R. Pechman, Lori L. Beason‐Held, Susan M. Resnick, Derek B. Archer, Angela L. Jefferson, Bennett A. Landman, Daniel Moyer

Abstract: Users should be cautious when performing LinearRISH harmonization. To select a reference site is to choose diffusion metric effect-size. Our proposed method eliminates the bias-inducing site selection step.

Introduction

Multi-site diffusion MRI studies are frequently hindered by "scanner effects," where hardware and protocol differences make data from different hospitals difficult to compare. While existing harmonization methods like LinearRISH help mitigate these effects, they require researchers to select an arbitrary "reference" site. This choice can bias final results, as the metrics of all other sites are forced to match the reference. MidRISH addresses this by projecting data from all sites into a neutral "mid-space," providing an unbiased way to combine datasets without sacrificing accuracy.

Methods

The authors propose MidRISH as a modification of the LinearRISH framework. The process involves several key steps:

  1. RISH Features: Both methods utilize Rotationally Invariant Spherical Harmonics (RISH), mathematical descriptions of the diffusion signal that remain consistent regardless of the patient's head orientation in the scanner.
  2. The "Mid-Space" Projection: Instead of scaling Site A to match Site B (using a scaling factor $\Phi$) or vice versa ($\Phi^{-1}$), MidRISH calculates the geometric midpoint between the two. It applies a square-root scaling factor ($\Phi^{1/2}$) to project both sites into a shared, neutral "mid-space."
  3. B-Value Mapping: To account for different gradient strengths across studies, a preprocessing step uses known linear decay properties to normalize b-values before harmonization.
  4. Registration: Non-linear registration (ANTs) ensures voxels are correctly aligned across subjects and sites before calculating average RISH features.
Schematic of the MidRISH framework showing the projection of Site A and Site B into a neutral mid-space using square-root scaling factors.

Datasets

The study validated MidRISH using two distinct scenarios:

  • Same Study, Different Scanners: Data from the ADNI (Alzheimer’s Disease Neuroimaging Initiative) database, comparing 37 subjects scanned on GE 3T hardware against 37 matched subjects on Siemens 3T hardware.
  • Different Studies, Different Protocols: A cross-study analysis comparing VMAP (Vanderbilt Memory and Aging Project) and BLSA (Baltimore Longitudinal Study of Aging). This involved 117 matched pairs (234 total subjects) with varying b-values (1000 vs. 700 s/mm²) and spatial resolutions.

Key Results and Insights

MidRISH effectively eliminates the bias inherent in reference selection. In the ADNI experiments, MidRISH moved both GE and Siemens data toward a common mean, whereas traditional LinearRISH would force one to adopt the characteristics of the other.

Qualitative brain maps and quantitative violin plots showing the convergence of Mean Diffusivity (MD) values from two different sites (A and B) to a shared mid-space (A' and B').

Key findings include:

  • Harmonization Efficacy: MidRISH reduces site-related differences in Mean Diffusivity (MD) and Fractional Anisotropy (FA) by an order of magnitude, matching the effectiveness of traditional approaches without the associated bias.
  • Tractometry Consistency: Analysis of 72 white matter bundles showed that MidRISH consistently placed harmonized metrics exactly in the middle of the two original site means.
  • Quantitative Improvement: In the VMAP/BLSA comparison, the raw difference in MD was $7.2 \times 10^{-4}$, which MidRISH reduced to $7.5 \times 10^{-5}$ in the mid-space.

Limitations and Future Work

While promising, MidRISH has limitations. The study focused on cognitively unimpaired individuals; further research is needed to determine how the method handles extreme anatomy, such as large tumors or significant atrophy, where registration might fail. Additionally, like all voxel-wise methods, MidRISH is sensitive to image registration quality. While the paper provides a formula for a "multivariate midpoint" for three or more sites, experimental validation has currently only been performed for the two-site case. Testing on larger, multi-site datasets remains a logical next step.

Summary updated

Abstract

Users should be cautious when performing LinearRISH harmonization. To select a reference site is to choose diffusion metric effect-size. Our proposed method eliminates the bias-inducing site selection step.
BibTeX
@inproceedings{newlin2024midrish,
  author = {Nancy R. Newlin and Michael E. Kim and Praitayini Kanakaraj and Tianyuan Yao and Timothy J. Hohman and Kimberly R. Pechman and Lori L. Beason‐Held and Susan M. Resnick and Derek B. Archer and Angela L. Jefferson and Bennett A. Landman and Daniel Moyer},
  title = {{MidRISH: Unbiased harmonization of rotationally invariant harmonics of the diffusion signal}},
  booktitle = {Magnetic},
  year = {2024},
  doi = {10.1016/j.mri.2024.03.033},
}
Figure