Manual segmentation versus semi-automated segmentation for quantifying vestibular schwannoma volume on MRI

Hari McGrath, Peichao Li, Reuben Dorent, Robert Bradford, Shakeel R. Saeed, Sotirios Bisdas, Sébastien Ourselin, Jonathan Shapey, Tom Vercauteren

Abstract

Manual 3D segmentation of brain tumors is the gold standard for accuracy but is notoriously slow for clinical use. This study demonstrates that semi-automated tools can reduce segmentation time for vestibular schwannomas by nearly 65% while maintaining clinical-grade accuracy. However, the "black box" nature of these algorithms introduces a unique set of user frustrations and higher cognitive loads compared to traditional manual methods.

Introduction

Vestibular schwannoma (VS) is a benign tumor of the vestibulocochlear nerve. In standard clinical practice, clinicians typically measure these tumors by their largest linear diameter on an MRI. While efficient, this one-dimensional measurement serves as a poor proxy for actual 3D volume, which is critical for tracking tumor growth or planning precision treatments like stereotactic radiosurgery.

Volumetric segmentation—tracing the tumor slice-by-slice—is the ideal solution, but manual segmentation is a grueling, time-intensive task. While fully automated AI solutions are emerging, they often lack the transparency and reliability required for clinical trust. This study explores the "middle ground": semi-automated segmentation, where a human provides minimal input to guide an algorithm.

Methodology

The researchers compared two distinct software approaches using five observers ranging from medical students to neurosurgeons:

  1. Manual (ITK-SNAP): The traditional method where users manually outline tumor boundaries in every MRI slice.
  2. Semi-automated (ImFusion Labels): Users provide "background" and "foreground" labels (scribbles), and the software uses an interactive segmentation module to grow the region.
Semi-automated segmentation interface showing foreground (red) and background (blue) labels used to guide the algorithm.

The study utilized four contrast-enhanced T1-weighted MRI scans representing a range of tumor sizes. Accuracy was benchmarked against expert ground-truth segmentations using the Dice coefficient, Relative Volume Error (RVE), and Average Symmetric Surface Distance (ASSD). Additionally, the NASA Task Load Index (TLX) was used to measure the cognitive cost of each tool.

Comparative Performance

Speed and Accuracy Parity

The most significant finding was that accuracy does not have to be sacrificed for speed. The semi-automated approach achieved Dice scores (~0.91) nearly identical to manual tracing but did so in a fraction of the time. Semi-automated segmentation took an average of 167 seconds per tumor, compared to 479 seconds for manual segmentation ($p < 0.001$).

Comparison of a raw axial T1-weighted MRI (left) and the resulting tumor segmentation (right).

The "Frustration Factor"

Despite the physical and temporal ease of the semi-automated tool, it was found to be more mentally taxing. NASA TLX scores revealed that the semi-automated tool was significantly more frustrating (+7.4 points) and mentally demanding (+7.8 points) than the manual alternative. Users reported feeling a loss of control; when the algorithm made an error, they felt they had fewer tools to correct it compared to the pixel-by-pixel control of manual segmentation.

Conclusion

Semi-automated tools offer a viable path toward democratizing volumetric data in clinical settings, allowing both experts and novices to produce high-quality data quickly. However, for these tools to gain widespread clinical adoption, developers must move toward "interactive" AI. Future tools should combine the speed of semi-automation with the intuitive, granular correction capabilities of manual tools to bridge the gap between efficiency and clinician trust.

Summary updated

Abstract

Purpose Management of vestibular schwannoma (VS) is based on tumour size as observed on T1 MRI scans with contrast agent injection. The current clinical practice is to measure the diameter of the tumour in its largest dimension. It has been shown that volumetric measurement is more accurate and more reliable as a measure of VS size. The reference approach to achieve such volumetry is to manually segment the tumour, which is a time intensive task. We suggest that semi-automated segmentation may be a clinically applicable solution to this problem and that it could replace linear measurements as the clinical standard. Methods Using high-quality software available for academic purposes, we ran a comparative study of manual versus semi-automated segmentation of VS on MRI with 5 clinicians and scientists. We gathered both quantitative and qualitative data to compare the two approaches; including segmentation time, segmentation effort and segmentation accuracy. Results We found that the selected semi-automated segmentation approach is significantly faster (167 s vs 479 s, $$p<0.001$$ p < 0.001 ), less temporally and physically demanding and has approximately equal performance when compared with manual segmentation, with some improvements in accuracy. There were some limitations, including algorithmic unpredictability and error, which produced more frustration and increased mental effort in comparison with manual segmentation. Conclusion We suggest that semi-automated segmentation could be applied clinically for volumetric measurement of VS on MRI. In future, the generic software could be refined for use specifically for VS segmentation, thereby improving accuracy.
BibTeX
@article{mcgrath2020manual,
  author = {Hari McGrath and Peichao Li and Reuben Dorent and Robert Bradford and Shakeel R. Saeed and Sotirios Bisdas and Sébastien Ourselin and Jonathan Shapey and Tom Vercauteren},
  title = {{Manual segmentation versus semi-automated segmentation for quantifying vestibular schwannoma volume on MRI}},
  journal = {Int. J. Comput. Assist. Radiol. Surg.},
  year = {2020},
  doi = {10.1007/s11548-020-02222-y},
}
Figure