Magnetic Circuit Analysis of Halbach Array and Improvement of Permanent Magnetic Adsorption Device for Wall-Climbing Robot

Shilong Jiao, Xiaojun Zhang, Xuan Zhang, Jidong Jia, Minglu ZhangSymmetry 2022 · OpenReview

TL;DR

This paper presents a new method for calculating the magnetic adsorption force of Halbach arrays, crucial for wall-climbing robots. By introducing an "equivalent magnetic flux density" that accounts for material properties and end effects, they improved the design of a permanent magnetic adsorption device, leading to a significant 24.63% increase in adsorption force.

What Problem Does This Paper Address?

Wall-climbing robots utilizing permanent magnets offer advantages in safety and load capacity compared to other designs. However, accurately calculating the magnetic adsorption force of these robots, especially those employing complex Halbach arrays, has been a challenge. Existing theoretical analyses are often insufficient, and numerical methods like the magnetic node method can be computationally complex. Furthermore, optimizing the design of the permanent magnetic adsorption device for maximum force while considering practical constraints like material properties and end effects is difficult. This paper aims to bridge this gap by providing a more accurate and practical theoretical framework for analyzing Halbach arrays and using it to improve the performance of a wall-climbing robot's adsorption system.

Methods

The authors tackle the problem by first developing a theoretical model for the magnetic flux density of a Halbach array. They extend existing work by considering magnets with perpendicular magnetization directions and incorporating the "end effect" of the magnets. A key innovation is the introduction of an "equivalent magnetic flux density" that simplifies calculations by accounting for the concentrated magnetic phenomenon of ferromagnetic materials and the end effects. This equivalent flux density is then used to calculate the magnetic adsorption force. To validate and refine their theoretical approach, they employ ANSYS software for finite element analysis (FEA) and conduct experimental measurements. The paper also details the process of optimizing the Halbach array configuration by analyzing the magnetic adsorption force under varying numbers of magnets and their relative widths.

Datasets

Not discussed in the paper. The study relies on theoretical modeling, simulation using ANSYS, and experimental measurements rather than pre-existing datasets.

Key Insights and Ideas

  • The "Equivalent Magnetic Flux Density" is a Game Changer: By introducing this concept, the authors simplify the complex magnetic field calculations for Halbach arrays, making theoretical analysis more tractable and accurate, especially when considering the interaction with ferromagnetic surfaces.
  • End Effects Matter (and can be approximated): The paper highlights that the theoretical models often deviate from reality at the ends of the magnetic circuit due to end effects. Their method of approximating these effects by connecting points from the middle of the end magnets significantly improves the accuracy of their equivalent magnetic flux density calculations.
  • Halbach Array Optimization is Non-Trivial: The study demonstrates that the magnetic adsorption force doesn't simply increase with more magnets. There's an optimal configuration, found through analysis and simulation, that maximizes force for a given volume. In this case, an optimal width ratio for the vice magnets was identified.
  • Experimental Validation is Crucial: The theoretical and simulation results are robustly validated by experimental measurements, confirming the effectiveness of their improved design and calculation method.

Key Results

  • The proposed "equivalent magnetic flux density" method, which accounts for end effects, shows good agreement with finite element analysis results, especially as the number of magnets in the Halbach array increases.
  • Through analysis and simulation, the authors identified an improved Halbach array configuration for the permanent magnetic adsorption device.
  • Experimental verification demonstrated that the improved adsorption device achieved a 24.63% increase in magnetic adsorption force compared to the original design, using the same volume of permanent magnets.

Limitations and Future Work

  • Harmonic Order Limitation: The theoretical analysis, while improved, still relies on considering a limited number of harmonic orders. The paper notes that higher harmonics can contribute to discrepancies between theoretical and FEA results, particularly at the ends of the magnets.
  • Magnetic Concentration Coefficient: The paper uses a magnetic concentration coefficient of 2 for carbon steel. This value might need to be adjusted for different ferromagnetic materials.
  • Future Work: The authors suggest that their work has potential applications in various interdisciplinary fields, including smart industries, ubiquitous environments, Industry 4.0, and medical devices. Further research could explore the application of their methods to different types of wall-climbing robots or other magnetic-based systems. The lightweight design of the improved adsorption device also opens avenues for further miniaturization and integration.

Summary updated

Abstract

To solve the problems that the theoretical analysis of Halbach array magnetic circuit is insufficient and that calculating the magnetic adsorption force of a permanent magnet by using the magnetic node method is complex, the magnetic flux density of a Halbach array magnetic circuit composed of multiple permanent magnets with perpendicular magnetization directions is calculated. On the basis of the concentrated magnetic phenomenon of the ferromagnetic material and the end effect of the permanent magnet, a method for calculating the magnetic adsorption force of the Halbach array magnetic circuit by using the equivalent magnetic flux density is proposed, and the variation trend of magnetic adsorption force after changing the parameters of the magnetic circuit is obtained. ANSYS software is used to analyze several magnetic circuits that produce large magnetic adsorption force, a magnetic circuit structure that produces the largest magnetic adsorption force is determined, and the permanent magnetic adsorption device of the wall-climbing robot is improved. The magnetic adsorption force of the wall-climbing robot before and after the improvement of the permanent magnetic adsorption device is measured through experiments. The experimental results show that the magnetic adsorption force after the improvement is increased by 24.63% compared to before the improvement.
BibTeX
@inproceedings{jiao2022magnetic,
  author = {Shilong Jiao and Xiaojun Zhang and Xuan Zhang and Jidong Jia and Minglu Zhang},
  title = {{Magnetic Circuit Analysis of Halbach Array and Improvement of Permanent Magnetic Adsorption Device for Wall-Climbing Robot}},
  booktitle = {Symmetry},
  year = {2022},
  url = {https://openreview.net/forum?id=Rcys5s3Qq9},
}
Figure