Lightweight Hypercomplex MRI Reconstruction: A Generalized Kronecker-Parameterized Approach

Haosen Zhang, Jiahao Huang, Yinzhe Wu, Congren Dai, Fanwen Wang, Zhenxuan Zhang, Guang Yang

Abstract

Accelerating Magnetic Resonance Imaging (MRI) through undersampling requires robust reconstruction algorithms, typically implemented via Deep Learning (DL). However, the high parameter count of state-of-the-art models poses significant challenges for deployment on clinical hardware. This paper presents a generalized Kronecker-parameterized hypercomplex framework designed to reduce the memory footprint of MRI reconstruction models by approximately 50% without compromising image fidelity. By treating complex-valued MRI data as hypercomplex entities and learning algebraic interaction rules through Kronecker factorization, we demonstrate that architectures like U-Net and SwinMR can be significantly compressed while maintaining performance parity and improving generalization on small datasets.

1. Introduction

Magnetic Resonance Imaging (MRI) is a cornerstone of non-invasive clinical diagnosis, yet its utility is often limited by long acquisition times. To mitigate this, undersampling techniques—where fewer measurements are taken—are employed, necessitating sophisticated reconstruction models to recover high-quality images from partial data. While Deep Learning (DL) has set new benchmarks in this domain, the most effective models (e.g., SwinMR, U-Net) are computationally intensive and memory-heavy. This creates a barrier to integrating these models directly into MRI scanners or utilizing them in resource-constrained clinical environments. There is a critical need for "lightweight" architectures that preserve the high-fidelity output required for medical diagnosis.

2. Methodology

2.1 Hypercomplex Representation

MRI data is inherently complex-valued, consisting of real and imaginary components. Traditional DL approaches often treat these as two independent channels. In contrast, this study utilizes a hypercomplex representation, treating the real and imaginary parts as a single entity. This allows the network to better capture the underlying physical correlations between the components.

2.2 Kronecker Factorization

The core innovation is the replacement of standard weight matrices with Kronecker-parameterized layers. A standard weight matrix $W$ is decomposed into a sum of Kronecker products:

$$H = \sum_{i=1}^{r} A_i \otimes S_i$$

In this formulation:

  • $A_i$ is a small, learnable matrix that defines the "algebraic rules" of channel interactions.
  • $S_i$ is a significantly smaller version of the original weight matrix.

Unlike previous hypercomplex methods (such as Quaternion Neural Networks) that rely on fixed mathematical rules, this approach learns the interaction matrices. This flexibility allows the model to discover the most efficient way to process the relationship between data components for a specific task.

2.3 Generalized Modules

The authors developed three drop-in replacements for standard DL components to create lightweight variants of popular architectures:

  • Kronecker MLP: For dense layers.
  • Kronecker Window Attention: For Transformer-based models like SwinMR.
  • Kronecker Convolution: For standard CNNs like U-Net.

By setting the hypercomplex dimension ($n$) to 2, the parameter count is theoretically halved compared to real-valued counterparts.

3. Experimental Setup

3.1 Dataset

The methodology was evaluated using the FastMRI open repository, specifically focusing on single-coil knee MRI studies. The dataset included 684 non-fat-suppressed proton-density weighted scans, partitioned into 420 for training, 64 for validation, and 200 for holdout testing. All slices were preprocessed and cropped to $320 \times 320$ pixels.

3.2 Evaluation

The Kronecker-parameterized models were compared against standard U-Net and SwinMR architectures at $8\times$ and $16\times$ acceleration factors. Performance was measured using Peak Signal-to-Noise Ratio (PSNR) and parameter counts.

4. Results and Discussion

4.1 Parameter Efficiency

The Kronecker approach achieved substantial reductions in model size:

  • U-Net: Reduced from 5.65M to 2.63M parameters.
  • SwinMR: Reduced from 2.38M to 1.20M parameters.

4.2 Reconstruction Quality

Despite the 50% reduction in parameters, the image quality remained nearly identical. At $8\times$ acceleration, the Kronecker SwinMR achieved a PSNR of 29.35 dB, compared to the original SwinMR's 29.65 dB. At extreme $16\times$ undersampling, the performance gap remained statistically insignificant ($p > 0.05$), demonstrating the robustness of the compression technique.

4.3 Generalization and Overfitting

An unexpected benefit of the lightweight Kronecker models was improved generalization. When trained on a limited dataset (only 10% of the total data), the Kronecker variants maintained stable convergence and outperformed their full-sized counterparts, which tended to plateau or diverge. This suggests that standard MRI models are significantly over-parameterized and that the Kronecker constraint acts as a beneficial regularizer.

5. Conclusion

This research demonstrates that Kronecker-parameterized hypercomplex networks offer a viable path toward deploying high-performance MRI reconstruction models on resource-constrained hardware. By learning the algebraic interactions of complex-valued data, these models achieve a 50% reduction in parameters with negligible loss in image quality.

Future work will focus on extending this framework to multi-coil (parallel imaging) data, which is the standard in modern clinical practice, and validating the approach across a wider variety of anatomical regions, such as the brain and heart. Additionally, exploring higher hypercomplex dimensions ($n > 4$) may yield even greater compression, provided the balance between efficiency and performance is maintained.

Summary updated

BibTeX
@inproceedings{zhang2025lightweight,
  author = {Haosen Zhang and Jiahao Huang and Yinzhe Wu and Congren Dai and Fanwen Wang and Zhenxuan Zhang and Guang Yang},
  title = {{Lightweight Hypercomplex MRI Reconstruction: A Generalized Kronecker-Parameterized Approach}},
  booktitle = {MLMI @ MICCAI},
  year = {2025},
  doi = {10.1007/978-3-032-09513-8\_10},
}
Figure