Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der KooijarXiv 2026 · arXiv

TL;DR

Researchers have developed "Levio," an accelerated design pipeline that transforms a commercial passive back-exoskeleton into a smart, active device using off-the-shelf components. By retrofitting the Laevo Flex with high-performance actuators and sensors, the team created a system that provides more assistance during lifting while reducing resistance during bending, significantly improving user comfort and usability.

What Problem Does This Paper Address?

Occupational musculoskeletal disorders (MSDs), particularly low-back injuries, are a major global health and economic burden. While passive back-exoskeletons—which use springs or gas struts to store and release energy—are effective at reducing muscle strain, they are "dumb" systems. Their assistance is fixed by their geometry; they often resist the user while they are trying to bend down, which can be fatiguing.

Active (powered) exoskeletons solve this by providing programmable, task-specific assistance. However, building an active exoskeleton from scratch is a nightmare for researchers. Designing a comfortable, adjustable human-machine interface (the "suit" part) that can handle high forces is time-consuming and expensive. This paper proposes a "retrofit" approach: take a commercially proven, comfortable passive frame and add the "brains" and "brawn" to make it active.

Methods

The researchers used the Laevo Flex V3.0 as their base platform because its interface is already validated for comfort and fit across various body types.

Hardware Integration

  • Actuation: They replaced the original gas springs with two CubeMars AK10-9 quasi-direct-drive (QDD) actuators. QDDs were chosen because they are "backdrivable," meaning the user can still move freely even if the motors are off.
  • Sensing: They integrated two Inertial Measurement Units (IMUs) on the torso and pelvis to track the user's posture and a load cell at the rear to measure the actual force transmitted to the user.
  • Control: A Raspberry Pi 4 acts as the high-level controller, running a phase-dependent algorithm.
Fig. 1. Exploded-view of the mechanical frame for integrating the actuation system. The alignment hinge allowed preservation of passive degrees of freedom.

Control Strategy

The core innovation is the state-dependent controller. Unlike a passive spring that pushes back the same amount whether you are going down or coming up, Levio detects the movement phase:

  1. Bending Phase: The system provides lower assistance to reduce the effort needed to reach down.
  2. Lifting Phase: Once the user starts to stand up with a load, the system "latches" into a high-assistance mode to provide maximum support.
Fig. 3. Target nominal bending and lifting assistance command torques.

Datasets

The system was evaluated through a participant study involving 9 healthy volunteers (7 male, 2 female). The primary task was a standardized stoop lift of a 10kg weight. The researchers compared three conditions:

  1. Passive: Wearing the original Laevo Flex.
  2. Zero Torque: Wearing Levio with the motors on but commanded to provide no force (testing transparency).
  3. Active Assistance: Wearing Levio with the phase-dependent controller active.

Key Insights and Ideas

  • The "HMI Shortcut": By using a commercial frame, the researchers bypassed the iterative cycle of designing wearable interfaces. This allowed them to focus entirely on the mechatronics and control.
  • Breaking Symmetry: Passive systems are largely symmetric due to their elastic nature. Levio demonstrates that an active system can create a "positive work loop"—injecting energy exactly when needed (lifting) and getting out of the way when not (bending).
  • Subjective vs. Objective Gains: Interestingly, while the mechanical assistance increased, the subjective scores for discomfort were significantly lower in the active mode. This suggests that "smart" assistance feels more natural to the user than "constant" spring assistance.
Postures used for measurement: upright, stoop, and squat.

Key Results

  • Phase Modulation: Levio reduced resistive torque during bending to 17.9 ± 4.6 Nm (compared to 25.2 Nm for the passive device) and increased assistance during lifting to 37.7 ± 6.4 Nm (compared to 30.6 Nm).
  • Usability: The active system achieved a System Usability Scale (SUS) score of 81.7, the highest among all tested conditions.
  • Comfort: Participants reported the lowest mean global discomfort scores when using the active Levio system, with the most significant reductions noted in the lower back region.

Limitations and Future Work

  • Weight Penalty: The retrofit increased the device's mass from 4.3 kg to approximately 7 kg. Future iterations will need to focus on mass reduction in the power supply and electronics.
  • Structural Limits: During testing, the researchers noticed deformation in the thigh connectors at high torques, forcing them to limit assistance to 25 Nm per side instead of the 40 Nm design target. Redesigning these connectors is a priority.
  • Squatting Tasks: The current sensor setup (torso/pelvis IMUs) works well for stooping but struggled with squatting due to "thigh-pad migration." Adding a thigh-mounted IMU would be necessary for a truly universal lifting assistant.
  • Sample Size: The study was limited to 9 participants; larger-scale longitudinal studies are needed to confirm long-term biomechanical benefits.

Summary updated

Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.
BibTeX
@misc{kyriazis2026levio,
  author = {Ionnais Kyriazis and Mohamed Irfan Refai and Herman van der Kooij},
  title = {{Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device}},
  year = {2026},
  eprint = {2611.22767},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.22767},
}
Figure