Abstract
To minimize fatigue, sustain workloads, and reduce the risk of injuries, the exoskeleton Carry was developed. Carry combines a soft human-machine interface and soft pneumatic actuation to assist the elbow in load holding and carrying. We hypothesize that the assistance of Carry would decrease, muscle activity, net metabolic rate, and fatigue. With Carry providing 7.2 Nm of assistance, we found reductions of up to 50% for the muscle activity, up to 61% for the net metabolic rate, and up to 99% for fatigue in a group study of 12 individuals. Analyses of operation dynamics and autonomous use demonstrate the applicability of Carry to a variety of use cases, presumably with increased benefits for increased assistance torque. The significant benefits of Carry indicate this device could prevent systemic, aerobic, and/or possibly local muscle fatigue that may increase the risk of joint degeneration and pain due to lifting, holding, or carrying.
Introduction
Manual load handling—including holding, carrying, and lifting—is a leading cause of occupational injuries, ranging from acute muscle strain to chronic joint degeneration. While rigid exoskeletons exist, they are often heavy and suffer from "joint misalignment," where mechanical hinges do not perfectly match human bone structure, causing discomfort.
The "Carry" exoskeleton was developed to address the lack of lightweight, active solutions for isometric holding and carrying tasks, which are ubiquitous in nursing, construction, and logistics. The challenge is to provide meaningful torque assistance without adding excessive weight that becomes a net burden to the user.
System Design and Methods
The Carry exoskeleton utilizes a soft human-machine interface consisting of textile sleeves and soft pneumatic actuators (inflatable TPU/polyester tubes). The device weighs 1.85 kg and uses "force transmission triangles" to convert the expansion of the pneumatic tubes into elbow flexion torque.
Researchers tested 12 male subjects across several scenarios:
- Short Holding: Holding 5, 10, and 15 kg for 30 seconds.
- Long Holding: Holding 5 kg for 7 minutes.
- Carrying: Walking at 4 km/h while holding 5 kg for 7 minutes.
Metrics included Electromyography (EMG) for four key muscles, net metabolic rate via indirect calorimetry, and fatigue measured via Maximum Voluntary Isometric Contraction (MVIC) tests.
Key Results
Physiological Relief
The exoskeleton provided significant systemic relief, reducing activity not just in the biceps but also in the trapezius (shoulder stabilizer) and flexor carpi radialis (wrist stabilizer). This suggests that assisting the elbow reduces the stabilization burden on the entire upper body.
- Muscle Activity: Mean reductions of 35% for the biceps and 25% for the trapezius were observed across all scenarios.
- Metabolic Cost: Net metabolic rate dropped by 61% during long holding and 32% during carrying. This brought the energy expenditure of holding a 5 kg load down to levels near the NIOSH safety limit for an 8-hour shift.
- Fatigue Mitigation: In the 7-minute holding task, the "Exo Off" group showed a 12% drop in maximum strength due to fatigue, while the "Exo On" group showed 0% fatigue.
Torque and Efficiency
At a modest pressure of 1.22 bar, the device provided 7.2 Nm of total assistance (3.6 Nm per arm), accounting for roughly 43% of the torque required to hold a 5 kg load.
Portability and Future Work
While the experimental trials were tethered, the authors modeled three potential portable configurations—compressor-only, tank-only, and hybrid—to estimate future feasibility.
Future work will address limitations such as pressure-point discomfort at high assistance levels and the restriction of natural range of motion caused by soft actuators. Additionally, moving from manual switches to intent-based control (e.g., sensors) will be critical for practical, real-world manual labor applications.
Summary updated