Lesion Segmentation and RECIST Diameter Prediction via Click-Driven Attention and Dual-Path Connection

Youbao Tang, Ke Yan, Jinzheng Cai, Lingyun Huang, Guotong Xie, Jing Xiao, Jingjing Lu, Gigin Lin, Le Lu

Introduction

In clinical oncology, the Response Evaluation Criteria In Solid Tumors (RECIST) guideline is the gold standard for assessing tumor response to therapy. This process requires radiologists to manually measure the longest diameter (long axis) and its longest perpendicular diameter (short axis) on a CT slice. However, manual measurement is a significant bottleneck: it is time-consuming, tedious, and prone to high inter-observer variability. While full 3D segmentation would be more precise, it is too labor-intensive for daily clinical practice. This paper proposes the Prior-guided Dual-path Network (PDNet), a universal tool designed to automate lesion segmentation and RECIST diameter prediction using only a single user click as guidance.

Methods

PDNet operates in a two-stage pipeline: first, it extracts a "Lesion of Interest" (LOI) box, and then it performs fine-grained segmentation and measurement within that box. The architecture, illustrated in Figure 1, introduces three novel components to enhance performance:

  1. Click-driven Attention (Prior Encoder): Instead of treating a user's click as raw coordinates, PDNet transforms it into a distance map. The Prior Encoder then learns lesion-specific attention matrices, focusing the model's features on the specific area of interest regardless of the lesion's size or shape.
  2. Dual-path Connection: Standard decoders typically pass information in a top-down direction. PDNet introduces both top-down (T2D) and bottom-up (B2U) connections, allowing the model to simultaneously integrate global context with fine-grained boundary details.
  3. Scale-aware Attention (SA): Integrated into the decoder, this module adaptively selects the most relevant features across different scales and channels to refine segmentation boundaries.

The model utilizes a ResNeSt-50 backbone and is trained using a multi-task loss function that combines Mean Squared Error (for diameter endpoints) and IoU loss (for segmentation).

Architecture of PDNet featuring the Image Encoder, Prior Encoder, and Decoder with Scale-aware Attention modules.

Experimental Results

The authors evaluated PDNet on the massive DeepLesion dataset (over 32,000 images) and an External Test Set comprising 1,350 lesions from six public datasets to ensure real-world generalizability.

Quantitative Performance

PDNet consistently outperformed previous state-of-the-art (SOTA) models and the robust nnUNet baseline. As shown in Figure 4, PDNet achieved a Dice score of 0.924 on the DeepLesion test set, a significant improvement over the previous best of 0.912. Measurement precision also saw marked improvements, with the long-axis prediction error reduced to 1.733 mm.

Quantitative comparison of PDNet against state-of-the-art methods on DeepLesion and External test sets.

Key Insights

  • Segmentation as a Proxy: The authors found that using segmentation to locate the lesion was more reliable than standard bounding-box detection, which often missed the exact clicked area.
  • Iterative Refinement: Since DeepLesion lacks manual segmentation masks, the authors used an iterative strategy to "clean" the training data, starting with rough elliptical masks and refining them based on the model's own predictions.
  • Generalizability: PDNet maintained high performance (0.885 Dice) on the external test set, proving it understands lesion geometry rather than just memorizing the training data.

Conclusion

PDNet provides a robust and efficient framework for automated RECIST measurement, significantly reducing the manual workload for radiologists while improving measurement consistency. Future work will involve extending the framework from 2D slices to full 3D volumes to provide a more comprehensive view of tumor burden.

Summary updated

BibTeX
@inproceedings{tang2021lesion,
  author = {Youbao Tang and Ke Yan and Jinzheng Cai and Lingyun Huang and Guotong Xie and Jing Xiao and Jingjing Lu and Gigin Lin and Le Lu},
  title = {{Lesion Segmentation and RECIST Diameter Prediction via Click-Driven Attention and Dual-Path Connection}},
  booktitle = {International Conference on Medical Image Computing and Computer-Assisted Intervention},
  year = {2021},
  doi = {10.1007/978-3-030-87196-3\_32},
}
Figure