Lesion-Inspired Denoising Network: Connecting Medical Image Denoising and Lesion Detection

Kecheng Chen, Kun Long, Yazhou Ren, Jiayu Sun, Xiaorong Pu

Abstract

This paper presents LIDnet (Lesion-Inspired Denoising Network), a novel framework that integrates medical image denoising with downstream lesion detection. Traditional denoising methods often prioritize global mathematical metrics like PSNR, which can lead to the loss of critical clinical details through oversmoothing. LIDnet addresses this by employing a Region-of-Interest (ROI) perceptual loss and a collaborative training strategy. Experimental results on multiple CT datasets demonstrate that LIDnet significantly enhances both image quality and the performance of automated detection systems, providing a more clinically relevant approach to medical image restoration.

Introduction

In medical imaging, particularly Computed Tomography (CT), there is a constant trade-off between radiation dose and image quality. Low-dose CT (LDCT) is safer for patients but results in noisy images that can obscure tiny lesions, such as pulmonary embolisms or nodules. While deep learning has revolutionized denoising, most models are optimized for global metrics like Peak Signal-to-Noise Ratio (PSNR) or Structural Similarity (SSIM). These metrics do not always correlate with clinical utility; a high PSNR might be achieved by smoothing the image, which can accidentally blur the very lesions required for diagnosis. LIDnet aims to bridge this disconnect by treating denoising and detection as a collaborative duo.

Methodology

LIDnet is a "plug-and-play" framework that can be integrated with various existing denoising networks. Its architecture is built around three core innovations:

Overview of the LIDnet architecture and its joint multi-loss objective.
  1. ROI Perceptual Loss: Unlike standard perceptual loss that compares features across the entire image, LIDnet uses a Region Proposal Network (RPN) to identify potential lesion areas. It then calculates a perceptual loss specifically on these regions, forcing the model to prioritize the integrity of high-stakes diagnostic areas.
  2. Joint Multi-loss Objective: The network is trained using a combination of reconstruction loss (pixel-level accuracy), the novel ROI perceptual loss, and a detection loss (measuring the detector's performance).
  3. Collaborative Training Strategy (CTS): This iterative approach involves pre-training the detection network on high-quality images, followed by alternating training of the denoising and detection networks. The detector provides feedback on feature importance, while the denoiser provides cleaner inputs to improve detection.

Results and Discussion

The researchers evaluated LIDnet on three simulated low-dose CT datasets: PE-CT (pulmonary embolism), L-CT-A (lung adenocarcinoma), and L-CT-G (lung carcinoma). LIDnet was tested as an enhancement to five popular denoising baselines, including WGAN-VGG and MAP-NN.

Qualitative comparison of denoising results and lesion detection performance.

Quantitative Performance

In all tests, LIDnet significantly boosted performance:

  • Detection Accuracy: On the L-CT-G dataset, adding LIDnet to the MAP-NN baseline improved the Average Precision (AP-50) from 92.84 to 95.14.
  • Denoising Quality: On the PE-CT dataset, the WGAN-VGG baseline's PSNR increased from 27.49 dB to 35.51 dB when using the LIDnet framework.

Qualitative Analysis

Visual results showed that LIDnet-enhanced models produced much sharper lesion edges and fewer "waxy" artifacts compared to standard denoising methods. Furthermore, the preservation of radiomics features—quantitative measures of texture and homogeneity—indicated that LIDnet maintains the biological "signature" of lesions better than baseline methods.

Conclusion

LIDnet demonstrates that local quality in the ROI is more critical for clinical utility than global image smoothness. By including a detection network in the training loop, the denoiser learns to produce images specifically tailored for diagnostic observers. While the current study relies on simulated noise and focuses on CT, future work will explore real-world matched pairs and the generalization of this "lesion-inspired" approach to other modalities like MRI and Ultrasound.

Summary updated

BibTeX
@inproceedings{chen2021lesion,
  author = {Kecheng Chen and Kun Long and Yazhou Ren and Jiayu Sun and Xiaorong Pu},
  title = {{Lesion-Inspired Denoising Network: Connecting Medical Image Denoising and Lesion Detection}},
  booktitle = {ACM Multimedia},
  year = {2021},
  doi = {10.1145/3474085.3475480},
}