Abstract
Purpose: In surgical navigation, pre-operative organ models are presented to surgeons during the intervention to help them in efficiently finding their target. In the case of soft tissue, these models need to be deformed and adapted to the current situation by using intra-operative sensor data. A promising method to realize this are real-time capable biomechanical models. Methods: We train a fully convolutional neural network to estimate a displacement field of all points inside an organ when given only the displacement of a part of the organ's surface. The network trains on entirely synthetic data of random organ-like meshes, which allows us to generate much more data than is otherwise available. The input and output data is discretized into a regular grid, allowing us to fully utilize the capabilities of convolutional operators and to train and infer in a highly parallelized manner. Results: The system is evaluated on in-silico liver models, phantom liver data and human in-vivo breathing data. We test the performance with varying material parameters, organ shapes and amount of visible surface. Even though the network is only trained on synthetic data, it adapts well to the various cases and gives a good estimation of the internal organ displacement. The inference runs at over 50 frames per second. Conclusions: We present a novel method for training a data-driven, real-time capable deformation model. The accuracy is comparable to other registration methods, it adapts very well to previously unseen organs and does not need to be re-trained for every patient. The high inferring speed makes this method useful for many applications such as surgical navigation and real-time simulation.
Introduction
In image-guided surgery, surgeons rely on pre-operative scans (like CT or MRI) to locate tumors and critical vessels. However, organs are soft and shift due to breathing, surgical manipulation, or patient positioning. To maintain an accurate "map," pre-operative models must be updated in real-time using intra-operative data, such as laparoscopic video feeds.
Traditionally, this registration is performed using the Finite Element Method (FEM). While accurate, FEM is computationally expensive and requires precise knowledge of tissue elasticity (Young’s Modulus), which is difficult to measure in vivo. This paper proposes a shift toward data-driven deep learning, using a 3D convolutional neural network (CNN) to predict internal deformations at real-time speeds.
Methodology
The researchers developed a 3D U-Net style CNN that learns the general principles of soft tissue physics rather than specific anatomy.
Voxelization and Input
The organ and its surroundings are represented as a $64 \times 64 \times 64$ grid of voxels. For each voxel, the network receives five input channels:
- Signed Distance Function (SDF): Representing the organ's shape.
- Boundary Conditions: A mask indicating where the organ is fixed to other tissues.
- Surface Displacement: A 3D vector for the parts of the surface visible to the surgical camera.
Synthetic Training
To bypass the scarcity of medical imaging data, the model was trained on 10,000 synthetic, organ-like "blob" meshes. A standard FEM solver was used to simulate deformations on these blobs, providing the ground truth for the network. This approach allows the model to generalize to real human anatomy without needing patient-specific retraining.
Results and Evaluation
The system was evaluated across three distinct scenarios: high-fidelity in-silico liver models, a silicone liver phantom with physical markers, and human in-vivo breathing data.
Key Findings
- Speed: The model performs inference at over 50 frames per second (approx. 20ms), making it suitable for real-time surgical display.
- Accuracy: On the silicone phantom, the model achieved an average error of 5.1 mm, comparable to state-of-the-art FEM-based methods.
- Robustness: The system maintained performance even when only 18-20% of the organ's surface was visible, a common constraint in laparoscopic surgery.
- Generalization: The results suggest that boundary conditions (knowing where an organ is fixed) are often more critical for accuracy than exact tissue stiffness parameters.
Conclusion
This work presents a significant advancement in real-time surgical navigation. By utilizing synthetic data and 3D convolutions, the authors created a model that is both fast and adaptable to previously unseen organs. While limitations remain regarding grid resolution and the complexity of surgical body forces, this approach paves the way for physics-aware AI assistants in the operating room.
Summary updated