Abstract
Current evaluation of large language models (LLMs) overwhelmingly prioritizes accuracy; however, in real-world and safety-critical applications, the ability to abstain when uncertain is equally vital for trustworthy deployment. We introduce MedAbstain, a unified benchmark and evaluation protocol for abstention in medical multiple-choice question answering (MCQA) -- a discrete-choice setting that generalizes to agentic action selection -- integrating conformal prediction, adversarial question perturbations, and explicit abstention options. Our systematic evaluation of both open- and closed-source LLMs reveals that even state-of-the-art, high-accuracy models often fail to abstain with uncertain. Notably, providing explicit abstention options consistently increases model uncertainty and safer abstention, far more than input perturbations, while scaling model size or advanced prompting brings little improvement. These findings highlight the central role of abstention mechanisms for trustworthy LLM deployment and offer practical guidance for improving safety in high-stakes applications.
Introduction
In high-stakes fields like medicine, an overconfident wrong answer is far more dangerous than a simple "I don't know." While current Large Language Models (LLMs) are reaching expert-level accuracy on medical exams, they suffer from a significant "reliability gap." They often hallucinate or provide definitive answers even when the input is ambiguous, underspecified, or missing critical patient data. Most existing benchmarks prioritize accuracy above all else, failing to measure a model's ability to withhold an answer under clinical uncertainty. For an LLM to be truly "trustworthy," it must not only be right but also be aware of when it is likely to be wrong.
The MedAbstain Framework
To address this gap, the researchers introduced MedAbstain, a systematic evaluation protocol that moves beyond simple accuracy. The framework utilizes two primary medical MCQA datasets: MedQA (USMLE) and AMBOSS. These are modified into four variants: Normal (NA), Abstention-enabled (A), No-Abstention Perturbed (NAP), and Abstention-enabled Perturbed (AP).
The core methodology involves several innovative components:
- Conformal Prediction (CP): A statistical tool used to quantify uncertainty by generating a "prediction set" of plausible labels. If the set contains multiple options, the model is considered uncertain.
- Explicit Abstention Options: Modifying standard questions by adding a randomly positioned "I am unable to answer this question" option.
- Adversarial Perturbations: Using a "teacher" model (GPT-4.1-mini) to identify and remove the most critical piece of information (the "gold context") from a medical case, simulating real-world clinical ambiguity.
- Scoring Functions: Utilizing Least Ambiguous Classifier (LAC) and Adaptive Prediction Set (APS) to measure the size and quality of prediction sets across various prompting strategies (Zero-shot, Few-shot, and Chain-of-Thought).
Key Insights and Ideas
The study reveals several critical aspects of LLM behavior in medical contexts:
- The "Abstention Option" as a Calibration Tool: Simply adding an "Abstain" choice consistently increased the model's internal uncertainty. The presence of the option itself acts as a signal for the model to be more cautious.
- Perturbation vs. Explicit Options: Removing key clinical details (the NAP variant) had a surprisingly small effect on model uncertainty compared to providing an explicit abstention option. This suggests LLMs are "trained to please" and will guess unless given a clear "way out."
- The Failure of Scaling: Larger models and advanced techniques like Chain-of-Thought (CoT) did not consistently improve abstention performance. In some cases, CoT actually made models more overconfident without increasing safety.
- Precision-Recall Gap: Human evaluation showed that when models do abstain, they are usually correct to do so (71.43% precision). However, they fail to abstain in the vast majority of cases where a human expert would (only 13.16% recall).
Experimental Results
The results validate Conformal Prediction as a reliable metric for safety, showing a strong positive correlation between a model's uncertainty and its likelihood to abstain.
Even state-of-the-art models like GPT-4.1 and Qwen-32B struggle with the "Perturbed + Abstention" (AP) variant. While accuracy drops when information is removed, models often fail to select the "Abstain" option, opting instead to guess. Notably, enabling "thinking" modes in models like Qwen slightly improved accuracy but actually decreased the abstention rate, making the models more confident even when they shouldn't be.
Conclusion and Future Work
MedAbstain highlights the central role of abstention mechanisms for trustworthy LLM deployment. While current models are far too "brave" for clinical use, providing explicit abstention options offers a practical path toward safer deployment. Future work should extend this benchmark to multi-modal tasks and free-form generative medical reasoning to better capture the complexity of clinical dialogue.
Summary updated