NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Influence of region‑of‑interest designs on quantitative measurement of multimodal imaging of MR non‑enhancing gliomas

Koji Takano, Manabu Kinoshita, Hideyuki Arita, Yoshiko Okita, Yasuyoshi Chiba, Naoki Kagawa, Yoshiyuki Watanabe, Eku Shimosegawa, Jun Hatazawa, Naoya Hashimoto, Yasunori Fujimoto, Haruhiko KishimaOncology 2018

Abstract

A number of studies have revealed the usefulness of multimodal imaging in gliomas. Although the results have been heavily affected by the method used for region of interest (ROI) design, the most discriminatory method for setting the ROI remains unclear. The aim of the present study was to determine the most suitable ROI design for <sup>18</sup>F-fluorodeoxyglucose (FDG) and <sup>11</sup>C-methionine (MET) positron emission tomography (PET), apparent diffusion coefficient (ADC), and fractional anisotropy (FA) obtained by diffusion tensor imaging (DTI) from the viewpoint of grades of non-enhancing gliomas. A total of 31 consecutive patients with newly diagnosed, histologically confirmed magnetic resonance (MR) non-enhancing gliomas who underwent FDG-PET, MET-PET and DTI were retrospectively investigated. Quantitative measurements were performed using four different ROIs; hotspot/tumor center and whole tumor, constructed in either two-dimensional (2D) or three-dimensional (3D). The most discriminating ROI for non-enhancing glioma grading was different according to the different imaging modalities. 2D-hotspot/center ROI was most discriminating for FDG-PET (P=0.087), ADC map (P=0.0083), and FA map (P=0.25), whereas 3D-whole tumor ROI was best for MET-PET (P=0.0050). In the majority of scenarios, 2D-ROIs performed better than 3D-ROIs.

Introduction

In neuro-oncology, quantitative imaging—including PET scans and Diffusion Tensor Imaging (DTI)—is essential for grading gliomas without invasive surgery. However, a significant challenge remains: there is no global standard for defining the "region of interest" (ROI) used to extract quantitative data. Some researchers focus on the "hotspot" (the most intense area), while others analyze the "whole tumor." Furthermore, the choice between a single 2D slice and a 3D volume adds another layer of complexity. This lack of standardization often leads to conflicting results in literature, particularly regarding whether metrics like the Apparent Diffusion Coefficient (ADC) can reliably distinguish between low-grade and high-grade gliomas.

Methods and ROI Design

This study retrospectively analyzed 31 patients with histologically confirmed non-enhancing gliomas (21 Grade II and 10 Grade III). Each patient underwent a comprehensive imaging battery including <sup>18</sup>F-FDG PET, <sup>11</sup>C-MET PET, and DTI (to calculate ADC and FA).

Four ROI designs were tested for every modality:

  1. 2D-Whole Tumor (WT): Delineated on a single axial slice.
  2. 3D-Whole Tumor (WT): Delineated across the entire tumor volume.
  3. 2D-Hotspot/Center (HC): A small region on the most intense area (or center) in one slice.
  4. 3D-Hotspot/Center (HC): A small volume spanning three or more consecutive slices.
Example of multimodal imaging (FLAIR, MET-PET, ADC) and the corresponding ROI placements used to evaluate tumor grade.

Key Insights: The Impact of Tissue Contamination

The study highlights that the optimal ROI design is dictated by the physical and biological properties of the imaging modality. A primary factor is "tissue contamination":

  • MET-PET: This modality has very low background uptake in normal brain tissue. Because the signal is "clean," a 3D-Whole Tumor ROI performs best (P=0.0050) as it captures the total metabolic burden of the lesion with minimal noise.
  • ADC and FDG: These are highly sensitive to surrounding healthy tissue (gray matter for FDG, white matter for ADC). Including the tumor margins in a "whole tumor" ROI often "contaminates" the signal with healthy tissue, obscuring the tumor's true metabolic or structural state. For these modalities, narrowing the ROI to a 2D-Hotspot/Center away from the margins provides a more accurate measurement of malignancy.

Results: Modality-Specific Performance

The most discriminating ROI varied significantly by modality. Surprisingly, 3D ROIs were not universally superior; in many cases, carefully selected 2D slices performed as well as or better than complex 3D volumes.

ROC curves comparing the diagnostic performance of different ROI designs for tumor grading.
  • MET-PET: 3D-Whole Tumor was superior (P=0.0050).
  • ADC Map: 2D-Hotspot/Center was superior (P=0.0083).
  • FDG-PET: 2D-Hotspot/Center was most discriminating (P=0.087).
  • FA Map: 2D-Hotspot/Center was the best of the tested ROIs (P=0.25).

Conclusion and Limitations

The findings suggest that "one size does not fit all" in neuroimaging analysis. Researchers must tailor their ROI strategy to the specific modality being used. While this study provides a clear direction, it is limited by a relatively small sample size (n=31) and potential operator bias, as ROIs were drawn by a single expert. Future work should focus on inter-observer variability and the impact of ROI design on predicting molecular markers or overall survival.

Summary updated

BibTeX
@inproceedings{takano2018influence,
  author = {Koji Takano and Manabu Kinoshita and Hideyuki Arita and Yoshiko Okita and Yasuyoshi Chiba and Naoki Kagawa and Yoshiyuki Watanabe and Eku Shimosegawa and Jun Hatazawa and Naoya Hashimoto and Yasunori Fujimoto and Haruhiko Kishima},
  title = {{Influence of region‑of‑interest designs on quantitative measurement of multimodal imaging of MR non‑enhancing gliomas}},
  booktitle = {Oncology},
  year = {2018},
  doi = {10.3892/ol.2018.8319},
}
Figure