Abstract
Model predictive control (MPC) is a powerful control method that allows to directly include state and input constraints into the controller design. However, errors in the model, e.g., caused by unknown disturbances, can lead to constraint violation, loss of feasibility and deteriorate closed-loop performance. In this paper, we propose a new MPC scheme based on the internal model principle. This enables the MPC to reject unknown disturbances provided that the dynamics of the linear signal generator are known. We reformulate the output regulation problem as a stability problem, to ensure feasibility, constraint satisfaction, and convergence to the optimal reachable setpoint. The controller is validated on a real four-tank system.
Introduction
Model Predictive Control (MPC) has gained widespread popularity due to its ability to explicitly handle physical constraints, such as voltage limits or tank capacity. However, the performance of MPC is heavily dependent on the accuracy of the underlying mathematical model. In the presence of unknown disturbances or model mismatches, standard MPC formulations can suffer from constraint violations, loss of recursive feasibility, or persistent steady-state tracking errors.
Existing approaches to address these issues have significant drawbacks. Min-max MPC is often computationally prohibitive. Tube-based MPC typically only guarantees practical stability (convergence to a neighborhood of the target). Other methods, like velocity-form MPC or disturbance observers, frequently lack rigorous proofs for recursive feasibility and convergence under hard constraints. This work introduces IMMPC, a scheme designed to perfectly reject unknown disturbances—such as constant offsets or periodic vibrations—while maintaining the strict mathematical guarantees characteristic of reliable MPC.
Methods: Internal Model Principle in MPC
The core innovation of IMMPC is the integration of the internal model principle into the MPC framework. This principle suggests that a controller must contain a model of the disturbance to achieve perfect rejection.
The methodology involves three key steps:
- Disturbance-Free Prediction Model: The authors utilize linear filters to transform system states and inputs into "error approximations." Provided the type of disturbance dynamics is known (e.g., a constant or a specific frequency), these filters effectively cancel the disturbance's influence. This results in a prediction model that is independent of the actual disturbance values.
- Artificial Reference MPC: To maintain theoretical guarantees, the filtered model is integrated into an artificial reference MPC framework. Instead of tracking an unknown external target directly, the MPC optimizes over an artificial steady-state reference, penalizing deviations from it.
- Problem Reformulation: This setup reformulates the complex output regulation problem (tracking a moving target under unknown disturbances) into an asymptotic stability problem (driving filtered error states to zero). This allows the application of standard, rigorous MPC stability proofs.
Experimental Validation
The proposed IMMPC scheme was evaluated using a classic control benchmark: the four-tank system. Testing was conducted both in simulation and on a physical Quanser coupled tank plant.
Key Insights
- Structural Decoupling: By passing signals through filters containing the disturbance's roots (e.g., $1-z^{-1}$ for constant offsets), the MPC can predict future filtered states without knowing the disturbance's magnitude.
- Avoiding the Separation Principle: Unlike traditional disturbance observers, this filtering approach does not require a separate extended state observer. This is vital for constrained MPC, where the separation principle generally does not hold.
- Theoretical Rigor: The reformulation into a stabilization problem enables formal proofs of recursive feasibility, constraint satisfaction, and convergence to the optimal reachable output.
Results
The IMMPC scheme demonstrated robust performance across different scenarios:
- Simulation Results: In simulated environments, the controller successfully tracked unknown references while rejecting both constant and sinusoidal disturbances (10s period). Water levels and pump voltages remained strictly within predefined safety limits.
- Hardware Implementation: When deployed on the physical Quanser four-tank system, IMMPC effectively tracked unknown constant references. The hardware experiments highlighted the controller's constraint awareness; it actively modulated the system's approach speed when nearing physical boundaries (e.g., maximum tank capacity) and recovered rapidly from setpoint changes despite unmodeled nonlinearities in the real plant.
Conclusion and Future Work
While IMMPC offers significant advantages, it requires prior knowledge of the disturbance dynamics (e.g., specific frequencies). Additionally, an initialization phase is required whenever the disturbance type changes. Future research will explore combining IMMPC with tube-based MPC to improve transient constraint handling and developing adaptive mechanisms for disturbances with unknown or time-varying dynamics.