Geometrically focused training and evaluation of organs‐at‐risk segmentation via deep learning

Ruiyan Ni, Elizabeth Chuk, Kathy Han, Jennifer Croke, Anthony Fyles, Jelena Luković, Michael Milosevic, Benjamin Haibe‐Kains, Alexandra RinkMedical 2025 · DOI

TL;DR

This paper introduces a novel geometric evaluation metric, weighted Dice Similarity Coefficient (wDSC), that better correlates with dosimetric accuracy in radiotherapy planning than traditional metrics. They also developed a geometrically focused deep learning training method (DP loss) to improve organ-at-risk segmentation, particularly for structures near the target, showing promise for more precise and efficient radiotherapy.

What Problem Does This Paper Address?

Accurate segmentation of organs-at-risk (OARs) is crucial for effective radiotherapy planning, ensuring tumors receive adequate radiation while minimizing damage to surrounding healthy tissues. However, existing automated segmentation methods, often relying on deep learning, are typically evaluated using geometric metrics like volumetric Dice Similarity Coefficient (vDSC) and Hausdorff Distance (HD95). While useful, these metrics don't always align with clinical goals, especially in treatments like cervical brachytherapy where the dose to specific OAR regions closest to the high-risk clinical target volume (CTVHR) is paramount. The challenge is to develop evaluation metrics and training strategies that directly address this clinical need for precise OAR delineation near critical structures, ensuring dosimetric accuracy and ultimately improving patient outcomes.

Methods

The researchers developed a novel evaluation metric called the weighted Dice Similarity Coefficient (wDSC). This metric modifies the standard vDSC by incorporating a weighting factor based on the voxel distance to the CTVHR. This means that errors in segmenting OARs closer to the target have a greater impact on the wDSC score, making it a more sensitive indicator of clinically relevant accuracy.

To improve the deep learning model's focus on these near-target regions, they introduced a distance-penalized (DP) loss function. This loss function penalizes segmentation errors more heavily for voxels closer to the CTVHR, guiding the model to prioritize accuracy in these critical areas. They trained a 3D U-Net model using both standard loss functions (cross-entropy and Dice loss) and their proposed DP versions (DPCE and DPDiceCE) for comparison.

The study also included a pseudo-dosimetric evaluation by calculating the absolute D2cm³ difference (the difference in dose to the most irradiated 2 cm³ of an OAR) between auto-segmented and clinically derived contours. Finally, a clinical acceptability test was performed by a radiation oncology fellow to assess the practical utility of the auto-segmented contours.

Datasets

The study utilized two datasets:

  • Primary Dataset: 170 T2-weighted MR scans from 56 patients undergoing external beam radiotherapy (EBRT) and high-dose-rate (HDR) brachytherapy. This dataset was split into a training/validation set (45 patients, 150 scans) for five-fold cross-validation and a held-out testing set (11 patients, 20 scans).
  • Independent Internal Testing Dataset: 35 MR scans from 22 cervical cancer patients treated at their institution. This dataset was used to evaluate the generalizability of the models across different applicators and scanners.

Key Insights and Ideas

  • Geometric Accuracy Matters, But Proximity is Key: The study highlights that not all geometric errors are equal in radiotherapy. Errors near the target have a disproportionately larger impact on dose delivery, making metrics that account for this proximity crucial.
  • wDSC as a Better Surrogate for Dosimetry: The wDSC emerged as a more reliable indicator of dosimetric accuracy compared to traditional geometric metrics, suggesting it could streamline the evaluation of auto-segmentation models.
  • DP Loss Focuses the Model: The distance-penalized loss function effectively guides deep learning models to pay more attention to OARs near the target, leading to improved segmentation in these critical regions.
  • Clinical Relevance Beyond Pure Geometry: The research bridges the gap between purely geometric evaluation and actual clinical impact, demonstrating how improved segmentation can lead to more accurate dose calculations.

Key Results

  • wDSC Correlation: The wDSC showed a moderate negative correlation (r = -0.55) with D2cm³ accuracy, outperforming standard geometric metrics which had weak or negligible correlations.
  • DP Loss Performance: Models trained with DP loss functions consistently yielded higher wDSCs for most OARs, particularly for the sigmoid and small bowel, compared to their non-DP counterparts.
  • Dosimetric Improvements: DP loss models demonstrated reduced mean absolute D2cm³ differences, indicating enhanced dosimetry accuracy, although these improvements were not always statistically significant.
  • Clinical Acceptability: The DP group showed marginally superior clinical acceptability ratings, with DPCE loss leading to more acceptable contours in rectum and sigmoid.
  • Time Savings: While not a primary focus, the DP loss functions showed a reduced maximum revision time for contours, suggesting potential efficiency gains.
  • Independent Testing: The proposed DP loss functions showed small but consistent improvements in wDSC on the independent internal testing set, supporting their generalizability.

Limitations and Future Work

  • Single Institution Study: The study was conducted at a single institution with a limited cohort size. Future work will involve collecting more data and validating the model across multiple institutions.
  • Cervical Brachytherapy Focus: The wDSC was evaluated exclusively on cervical scans. The authors plan to expand its validation to other brachytherapy sites like prostate.
  • DP Loss Function Nuances: The current DP loss function assumes a stable relative distance between CTVHR and OARs. For scenarios with significant motion (e.g., lung cancer), the DP term might need customization.
  • Network Architecture: The DP loss was implemented with a 3D U-Net backbone. Future work will explore its integration with other architectures like transformers.
  • Clinical Acceptability Evaluator: The clinical acceptability test was performed by a single radiation oncologist. Involving more experts will provide a more robust evaluation of inter-observer variations.

Summary updated

Abstract

We developed and evaluated a new geometric metric, wDSC, as a better indicator of D2cm<sup>3</sup> accuracy, which has the potential to become a surrogate for dosimetric accuracy in cervical brachytherapy. The model with DP loss showed non-statistically significant improvements in geometric and dosimetric performance. This work also holds the potential to be used for precise OARs delineation in adaptive radiotherapy.
BibTeX
@inproceedings{ni2025geometrically,
  author = {Ruiyan Ni and Elizabeth Chuk and Kathy Han and Jennifer Croke and Anthony Fyles and Jelena Luković and Michael Milosevic and Benjamin Haibe‐Kains and Alexandra Rink},
  title = {{Geometrically focused training and evaluation of organs‐at‐risk segmentation via deep learning}},
  booktitle = {Medical},
  year = {2025},
  doi = {10.1002/mp.17840},
}
Figure