Abstract
Surgical automation requires precise guidance and understanding of the scene. Current methods in the literature rely on bulky depth cameras to create maps of the anatomy, however this does not translate well to space-limited clinical applications. Monocular cameras are small and allow minimally invasive surgeries in tight spaces but additional processing is required to generate 3D scene understanding. We propose a 3D mapping pipeline that uses only RGB images to create segmented point clouds of the target anatomy. To ensure the most precise reconstruction, we compare different structure from motion algorithms' performance on mapping the central airway obstructions, and test the pipeline on a downstream task of tumor resection. In several metrics, including post-procedure tissue model evaluation, our pipeline performs comparably to RGB-D cameras and, in some cases, even surpasses their performance. These promising results demonstrate that automation guidance can be achieved in minimally invasive procedures with monocular cameras. This study is a step toward the complete autonomy of surgical robots.
Introduction
Autonomous robotic surgery hinges on the ability to generate precise 3D maps of the surgical environment. While RGB-D (depth) and stereo cameras are standard in research, their physical bulk limits their utility in minimally invasive procedures. In environments like the human trachea, where space is at a premium for treating Central Airway Obstructions (CAO), surgeons rely on standard monocular endoscopes. These devices provide high-resolution 2D video but lack inherent depth data. This work presents a pipeline to transform these "flat" images into a reliable 3D guide for autonomous robotic resection.
Methodology and Experimental Setup
The proposed system bridges the gap between 2D monocular vision and 3D robotic action through a multi-stage pipeline. The researchers first evaluated several Structure from Motion (SfM) algorithms using the hloc toolkit to reconstruct the airway from unordered images. Combinations of feature detectors and matchers, such as DISK and LightGlue, were optimized for point cloud density.
To identify tumors within the 3D map, the Segment Anything Model (SAM) was utilized via a pseudo-labeling strategy. To mitigate lens distortion common in endoscopes, a weighted voting system prioritized labels from the center of the camera lens when projecting 2D data into 3D space. Finally, the resulting 3D map was registered to a UR10e robot's workspace, which planned a resection path using a polynomial surface model, maintaining a 1mm safety clearance above healthy tissue.
Key Results and Discussion
The pipeline was validated using ex-vivo sheep and porcine tissue models. The system achieved a registration accuracy of 0.41 ± 0.16 mm, which is well within the tolerances required for delicate airway surgery.
A key finding was that the SfM approach often outperformed traditional RGB-D cameras. By fusing over 20 different camera angles into a single global map, the multi-view SfM pipeline reduced noise and provided a more comprehensive scene understanding than a single-view depth snapshot. In tumor removal tasks, the SfM-guided robot demonstrated superior tissue preservation, showing significantly less collateral damage (charring and darkening) than previous RGB-D-based methods. The cut surface error (RMSE) was 2.223 mm, nearly matching the 1.976 mm achieved by bulky depth sensors.
Conclusion and Future Work
This study demonstrates that monocular cameras can provide sufficient 3D guidance for autonomous surgical tasks, rivaling specialized depth hardware. However, significant challenges remain. The current processing time of 20–40 minutes must be reduced to near real-time for clinical use. Furthermore, future iterations must account for tissue deformation caused by breathing and heartbeat, and transition from open tissue models to the constrained environment of the tracheal lumen.