Framework for quality assessment of whole genome cancer sequences

Justin P. Whalley, Ivo Buchhalter, Esther Rheinbay, Keiran Raine, Miranda D. Stobbe, Kortine Kleinheinz, Johannes Werner, Sergi Beltrán, Marta Gut, Daniel Hübschmann, Barbara Hutter, Dimitri Livitz, Marc D. Perry, Mara Rosenberg, Gordon Saksena, Jean-Rémi Trotta, Roland Eils, Daniela S. Gerhard, Peter J. Campbell, Matthias SchlesnerNature Communications 2020

Abstract

Bringing together cancer genomes from different projects increases power and allows the investigation of pan-cancer, molecular mechanisms. However, working with whole genomes sequenced over several years in different sequencing centres requires a framework to compare the quality of these sequences. We used the Pan-Cancer Analysis of Whole Genomes cohort as a test case to construct such a framework. This cohort contains whole cancer genomes of 2832 donors from 18 sequencing centres. We developed a non-redundant set of five quality control (QC) measurements to establish a star rating system. These QC measures reflect known differences in sequencing protocol and provide a guide to downstream analyses and allow for exclusion of samples of poor quality. We have found that this is an effective framework of quality measures. The implementation of the framework is available at: https://dockstore.org/containers/quay.io/jwerner_dkfz/pancanqc:1.2.2.

Introduction

In the era of "Pan-Cancer" research, scientists pool genomic data from dozens of international centers to increase statistical power. However, these sequences are often produced over many years using different protocols, machines, and library preparation methods. Mixing these disparate datasets creates a "garbage in, garbage out" risk. Without a consistent way to measure and compare the quality of sequences from different sources, researchers might draw false conclusions based on technical artifacts rather than actual biology. This paper addresses the lack of a unified, non-redundant framework for assessing the quality of whole-genome sequencing (WGS) in cancer.

The Five-Star QC Framework

The authors developed a set of five non-redundant QC measures that culminate in a 0 to 5-star rating system. For most measures, a full star is awarded if both the tumor and normal samples pass, while a half-star is given if only the normal sample passes—reflecting the fact that "normal" samples should technically be cleaner and serve as a benchmark for technical noise.

The five pillars of the framework are:

  1. Mean Coverage: A standard check of sequencing depth.
  2. Evenness of Coverage: This uses two distinct metrics—Median/Mean (MoM) and Full Width at Half Maximum (FWHM). Notably, FWHM is used to filter out biological noise (like copy number variations) to focus strictly on sequencing bias.
  3. Somatic Mutation Calling Coverage: Based on the MuTect algorithm, this checks if there is sufficient depth (at least 14 reads in the tumor and 8 in the normal) to actually call a mutation.
  4. Paired Reads Mapping to Different Chromosomes: While some inter-chromosomal mapping is biological (e.g., translocations), an excess (>3%) usually indicates technical artifacts from PCR amplification.
  5. Edit Ratio: This compares the mismatch rate between Read 1 and Read 2 in a pair. A high imbalance suggests a failure in a specific sequencing cycle.
Visualization of coverage evenness and quality thresholds.

Validation using the PCAWG Cohort

The framework was constructed and validated using the Pan-Cancer Analysis of Whole Genomes (PCAWG) cohort, which includes 2,959 normal-tumor pairs from 2,832 donors across 18 sequencing centers and 48 different projects.

Key Insights

  • Independence of Metrics: A Venn diagram analysis revealed that the five measures catch different types of failures with minimal overlap, confirming the framework is non-redundant.
  • Quality Drives Consensus: Sequence quality dictates scientific accuracy. Samples with 4 or 5 stars showed significantly higher agreement across four different mutation-calling algorithms. Specifically, samples with $\ge$ 4 stars had significantly higher proportions of somatic single base mutations (SSM) supported by all four callers ($p = 3.94 \times 10^{-4}$).
  • Protocol Evolution: The framework successfully tracked the history of the field. For instance, the shift to "PCR-free" protocols in 2012 led to a measurable jump in sequence evenness and overall star ratings.

Results and Impact

  • High-Quality Baseline: 66.4% of the PCAWG cohort achieved a perfect 5-star rating.
  • Efficiency Gains: Excluding a single 1-star sample early could have saved 55 days of computational runtime during the mutation-calling phase.
  • Widespread Utility: The framework proved robust across various tissue types, suggesting that quality differences are primarily project-based (protocol/center) rather than tissue-specific.

Limitations and Future Work

As sequencing technology improves, thresholds for "passing" will likely need to be tightened (e.g., moving from 30x to 100x coverage). Furthermore, while the star rating correlates with caller consensus, it only explains a small portion of the total variance in mutation calling, suggesting other hidden variables remain. Finally, the current framework is optimized for short-read sequencing (Illumina) and will need adaptation for long-read technologies where error profiles and mapping logic differ.

Summary updated

BibTeX
@inproceedings{whalley2020framework,
  author = {Justin P. Whalley and Ivo Buchhalter and Esther Rheinbay and Keiran Raine and Miranda D. Stobbe and Kortine Kleinheinz and Johannes Werner and Sergi Beltrán and Marta Gut and Daniel Hübschmann and Barbara Hutter and Dimitri Livitz and Marc D. Perry and Mara Rosenberg and Gordon Saksena and Jean-Rémi Trotta and Roland Eils and Daniela S. Gerhard and Peter J. Campbell and Matthias Schlesner and Marta Gut},