Abstract
Cardiovascular disease (CVD) screening faces significant challenges in resource-limited settings, where infrastructure and computational constraints preclude the use of advanced remote assessment. These constraints are particularly acute for people living with HIV (PLWH), who experience elevated CVD risk yet often receive care in clinics without the capacity for specialist diagnostics. We evaluate pretrained physiological embeddings from foundation models for CVD detection using low-cost wearable photoplethysmography (PPG) signals from 80 PLWH outpatients in Ho Chi Minh City, Vietnam. We compare a strictly zero-shot approach (NormWear applied without any local training) with a more practical pipeline that uses frozen PaPaGei embeddings plus a locally trained classifier. The PaPaGei-embedding approach achieved superior discrimination (AUROC 0.769) compared with zero-shot NormWear (0.610), traditional PCA features (0.651), and established clinical scores, including the Framingham score (0.551) and the D:A:D-modified Framingham score (0.462). Without fine-tuning the foundation model itself, PaPaGei embeddings captured clinically coherent structure: patients on dolutegravir-based regimens clustered in low-risk regions, while those with high cholesterol variability occupied high-risk areas, consistent with cardiometabolic pathophysiology. These results show that pretrained physiological embeddings can enable accurate screening when combined with lightweight local calibration, reducing reliance on extensive feature engineering while preserving pathophysiological plausibility and actionable triage behaviour in the learned embeddings. This provides a practical approach for deploying foundation models in resource-constrained settings where training deep models may be infeasible.
Introduction
People living with HIV (PLWH) face a 1.5 to 2-fold higher risk of cardiovascular disease (CVD) compared to the general population. In resource-limited settings like Vietnam, screening is a major hurdle as specialist diagnostics like 12-lead ECGs or echocardiography are often unavailable in routine outpatient clinics. Furthermore, traditional clinical risk scores, such as the Framingham score, are known to systematically underpredict risk in PLWH populations. This study explores a practical "middle ground" for deploying AI: using frozen foundation model embeddings from low-cost wearable pulse oximeter signals (PPG) to develop a screening tool that significantly outperforms traditional methods.
Methods
The researchers evaluated pretrained physiological embeddings from foundation models (NormWear and PaPaGei) for CVD detection. These models are pre-trained on massive datasets of heart signals to learn the "language" of human physiology. The study used a prospective dataset of 80 PLWH outpatients at the Hospital for Tropical Diseases in Ho Chi Minh City, Vietnam. Input data consisted of 20-minute PPG recordings (100 Hz) from a wearable pulse oximeter, with ground truth CVD status confirmed by expert cardiologists using 12-lead ECG and echocardiography.
The study compared three primary strategies:
- Strictly Zero-Shot: Using NormWear to generate risk probabilities without any local training.
- Frozen Embeddings + Local Classifier: Using PaPaGei as a fixed feature extractor (generating mathematical vectors or "embeddings") and training a lightweight Random Forest classifier on these vectors using local data.
- Baselines: Traditional clinical variables, handcrafted heart rate variability (HRV) features, and established risk scores (Framingham and D:A:D).
Results
The PaPaGei-embedding pipeline with a local classifier achieved the best results, significantly outperforming clinical baselines and zero-shot approaches. It reached an AUROC of 0.769 and an Average Precision of 0.489. Notably, the model achieved a recall of 1.000, meaning it successfully identified all confirmed CVD cases in the test set—a critical requirement for an effective triage tool.
Visualizing the predicted likelihood distributions demonstrates that the PaPaGei pipeline creates the clearest separation between healthy and CVD-positive patients compared to traditional risk scores. Even without fine-tuning on HIV-specific data, the embeddings captured clinically coherent structures; for instance, patients on dolutegravir-based regimens (associated with better cardiometabolic profiles) naturally grouped in low-risk regions of the model's latent space.
Discussion and Conclusion
These results demonstrate that pretrained physiological embeddings can enable accurate screening when combined with lightweight local calibration. This approach reduces reliance on manual feature engineering while preserving pathophysiological plausibility and actionable triage behavior. While the small sample size (N=80) is a limitation, the findings suggest a practical path for deploying foundation models in resource-constrained settings where training deep models from scratch is infeasible. Future work will focus on larger multi-center studies and exploring label-free anomaly scoring to further enhance screening efficiency without requiring local cardiologist-confirmed examples.
Summary updated