Abstract

Cardiac Magnetic Resonance (CMR) imaging is essential for assessing cardiac structure and function, but manual post-processing is time-consuming and tedious. While Fully Convolutional Networks (FCNs) have automated ventricular segmentation, their computational costs often hinder clinical deployment. We present FastVentricle, an FCN architecture based on ENet, optimized for efficiency. FastVentricle achieves a 4x speedup and 6x reduction in memory usage compared to previous state-of-the-art models while maintaining clinical accuracy.

Introduction

In clinical cardiology, Magnetic Resonance Imaging (CMR) is the gold standard for evaluating heart function. Calculating metrics such as ejection fraction requires precise contouring of ventricular boundaries across multiple image slices. Manually, this process can take upwards of 30 minutes per patient. While deep learning models like UNet have shown promise in automation, they are often computationally heavy, leading to high deployment costs and latency in clinical workflows. FastVentricle addresses this by bridging the gap between high-performance research models and efficient, production-ready tools.

Architecture and Methods

FastVentricle is based on the ENet (Efficient Neural Network) architecture, originally designed for real-time semantic segmentation. The model employs several key design choices to optimize for speed and memory:

  • Asymmetric Design: Unlike symmetric architectures like UNet, FastVentricle utilizes a large encoder to learn complex features and a significantly smaller decoder for image reconstruction. This reflects the insight that the decoder's role is primarily fine-tuning spatial details rather than feature extraction.
  • Skip Connections: To preserve the high-resolution details necessary for medical precision, skip connections were integrated to pass information from early layers directly to the decoder.
  • Bottleneck Modules: The network utilizes efficient convolutions (e.g., $1 \times n$ and $n \times 1$ filters) to reduce parameter counts without compromising the receptive field.
FastVentricle architecture based on ENet with skip connections.

Evaluation and Dataset

The model was trained and validated on a clinical database of 1,143 short-axis cine MRI scans. Annotations included the Left Ventricle (LV) endocardium, LV epicardium, and Right Ventricle (RV) endocardium at end-systole (ES) and end-diastole (ED).

Rather than relying solely on pixel-wise metrics like the Dice score, the authors prioritized Relative Absolute Volume Error (RAVE). RAVE is a more clinically relevant metric as it directly relates to the volumetric measurements used by clinicians for diagnosis. The test set was strictly curated using annotations from licensed radiologists to ensure a gold-standard comparison.

Experimental Results

FastVentricle demonstrated significant efficiency gains over the previous state-of-the-art, DeepVentricle, without a statistically significant loss in accuracy. As shown in the table below, the model size was reduced from 220MB to 10MB, and inference time dropped to just 7ms per sample.

Performance comparison between DeepVentricle and FastVentricle.

Statistical analysis confirmed that the median RAVE for both models (ranging between 5% and 7%) was statistically indistinguishable. This suggests that lightweight architectures can achieve clinical-grade results comparable to much larger, FDA-cleared models.

Discussion and Conclusion

Despite its success, FastVentricle faces challenges with congenital heart defects, where anatomy deviates significantly from standard training data. Additionally, determining the basal slice (the top of the ventricle) remains difficult for both AI and human annotators. Future work may explore "2.5D" architectures to incorporate spatial information from adjacent slices without the memory overhead of full 3D models.

In conclusion, FastVentricle provides a highly efficient alternative for cardiac segmentation, offering the performance required for real-time clinical applications while drastically reducing hardware requirements.

Summary updated

Abstract

Cardiac Magnetic Resonance (CMR) imaging is commonly used to assess cardiac structure and function. One disadvantage of CMR is that post-processing of exams is tedious. Without automation, precise assessment of cardiac function via CMR typically requires an annotator to spend tens of minutes per case manually contouring ventricular structures. Automatic contouring can lower the required time per patient by generating contour suggestions that can be lightly modified by the annotator. Fully convolutional networks (FCNs), a variant of convolutional neural networks, have been used to rapidly advance the state-of-the-art in automated segmentation, which makes FCNs a natural choice for ventricular segmentation. However, FCNs are limited by their computational cost, which increases the monetary cost and degrades the user experience of production systems. To combat this shortcoming, we have developed the FastVentricle architecture, an FCN architecture for ventricular segmentation based on the recently developed ENet architecture. FastVentricle is 4x faster and runs with 6x less memory than the previous state-of-the-art ventricular segmentation architecture while still maintaining excellent clinical accuracy.