Abstract
Cardiac Magnetic Resonance (CMR) imaging is essential for assessing cardiac structure and function, but manual post-processing is time-consuming and tedious. While Fully Convolutional Networks (FCNs) have automated ventricular segmentation, their computational costs often hinder clinical deployment. We present FastVentricle, an FCN architecture based on ENet, optimized for efficiency. FastVentricle achieves a 4x speedup and 6x reduction in memory usage compared to previous state-of-the-art models while maintaining clinical accuracy.
Introduction
In clinical cardiology, Magnetic Resonance Imaging (CMR) is the gold standard for evaluating heart function. Calculating metrics such as ejection fraction requires precise contouring of ventricular boundaries across multiple image slices. Manually, this process can take upwards of 30 minutes per patient. While deep learning models like UNet have shown promise in automation, they are often computationally heavy, leading to high deployment costs and latency in clinical workflows. FastVentricle addresses this by bridging the gap between high-performance research models and efficient, production-ready tools.
Architecture and Methods
FastVentricle is based on the ENet (Efficient Neural Network) architecture, originally designed for real-time semantic segmentation. The model employs several key design choices to optimize for speed and memory:
- Asymmetric Design: Unlike symmetric architectures like UNet, FastVentricle utilizes a large encoder to learn complex features and a significantly smaller decoder for image reconstruction. This reflects the insight that the decoder's role is primarily fine-tuning spatial details rather than feature extraction.
- Skip Connections: To preserve the high-resolution details necessary for medical precision, skip connections were integrated to pass information from early layers directly to the decoder.
- Bottleneck Modules: The network utilizes efficient convolutions (e.g., $1 \times n$ and $n \times 1$ filters) to reduce parameter counts without compromising the receptive field.
Evaluation and Dataset
The model was trained and validated on a clinical database of 1,143 short-axis cine MRI scans. Annotations included the Left Ventricle (LV) endocardium, LV epicardium, and Right Ventricle (RV) endocardium at end-systole (ES) and end-diastole (ED).
Rather than relying solely on pixel-wise metrics like the Dice score, the authors prioritized Relative Absolute Volume Error (RAVE). RAVE is a more clinically relevant metric as it directly relates to the volumetric measurements used by clinicians for diagnosis. The test set was strictly curated using annotations from licensed radiologists to ensure a gold-standard comparison.
Experimental Results
FastVentricle demonstrated significant efficiency gains over the previous state-of-the-art, DeepVentricle, without a statistically significant loss in accuracy. As shown in the table below, the model size was reduced from 220MB to 10MB, and inference time dropped to just 7ms per sample.
Statistical analysis confirmed that the median RAVE for both models (ranging between 5% and 7%) was statistically indistinguishable. This suggests that lightweight architectures can achieve clinical-grade results comparable to much larger, FDA-cleared models.
Discussion and Conclusion
Despite its success, FastVentricle faces challenges with congenital heart defects, where anatomy deviates significantly from standard training data. Additionally, determining the basal slice (the top of the ventricle) remains difficult for both AI and human annotators. Future work may explore "2.5D" architectures to incorporate spatial information from adjacent slices without the memory overhead of full 3D models.
In conclusion, FastVentricle provides a highly efficient alternative for cardiac segmentation, offering the performance required for real-time clinical applications while drastically reducing hardware requirements.
Summary updated