Introduction
For users of lower-limb exoskeletons (LLEs), maintaining balance is a critical safety requirement. While many existing systems assist with ankle or hip stability, the "stepping strategy"—taking a recovery step to regain balance—remains a significant challenge due to the complexity of real-time decision-making regarding step timing and placement.
ExoRecovery introduces a cooperative control framework for LLEs that optimizes both the timing and placement of a recovery step. By utilizing real-time optimization based on the Divergent Component of Motion (DCM), the system assists users in regaining balance after an external push, ensuring that robotic intervention aligns naturally with human intent.
Theoretical Framework
The ExoRecovery system is built upon the Linear Inverted Pendulum Model (LIPM), which simplifies human walking dynamics to facilitate real-time control. The core of the balance recovery logic relies on the Divergent Component of Motion (DCM), also known as the Extrapolated Center of Mass.
The DCM represents the direction of the body's momentum. If the DCM moves outside the base of support, a fall is imminent unless a recovery step is taken. The controller employs Quadratic Programming (QP) optimization to solve for the optimal foot position ($cop_T$) and step duration ($T$) that minimizes the DCM offset at the end of the step.
Control Architecture
The framework operates through a multi-layered control loop. Once the optimal step parameters are determined, the system generates a bio-inspired foot trajectory using 5th-order splines. These trajectories are converted into joint angles via inverse kinematics and executed through an impedance controller.
Unlike rigid position control, the impedance controller acts as a virtual spring, providing guidance while allowing for natural human variability. This "cooperative" approach ensures the robot assists rather than coerces the user's movement, which is essential for user comfort and safety.
Experimental Validation and Results
The framework was validated using the Autonomyo v2 exoskeleton prototype (20kg) with three healthy subjects. The researchers first conducted "zero-torque" tests to verify that the optimization algorithm's predictions aligned with natural human stepping behavior. They then tested the active assistance mode to evaluate stability and smoothness.
Key findings include:
- Bio-Compatibility: In zero-torque mode, the difference between human-selected landing positions and the algorithm's calculated optimal positions was minimal (between -5° and 10°), suggesting high alignment with human intuition.
- Enhanced Stability: During active assistance, joint trajectories were significantly smoother with reduced oscillations compared to unassisted recovery.
- Spatio-Temporal Optimization: The study demonstrated that optimizing step timing ($T$) is as crucial as step placement for effective balance recovery.
Conclusion and Future Work
ExoRecovery represents a significant step toward safe, omnidirectional balance assistance in wearable robotics. While current experiments focused on forward pushes, future work will address backward push recovery and the integration of ankle and hip strategies into a unified controller. Additionally, testing with individuals with gait impairments is necessary to validate the system's clinical utility in target populations.