Abstract
Amongst all medical biometric traits, Photoplethysmograph (PPG) is the easiest to acquire. PPG records the blood volume change with just combination of Light Emitting Diode and Photodiode from any part of the body. With IoT and smart homes' penetration, PPG recording can easily be integrated with other vital wearable devices. PPG represents peculiarity of hemodynamics and cardiovascular system for each individual. This paper presents non-fiducial method for PPG based biometric authentication. Being a physiological signal, PPG signal alters with physical/mental stress and time. For robustness, these variations cannot be ignored. While, most of the previous works focused only on single session, this paper demonstrates extensive performance evaluation of PPG biometrics against single session data, different emotions, physical exercise and time-lapse using Continuous Wavelet Transform (CWT) and Direct Linear Discriminant Analysis (DLDA). When evaluated on different states and datasets, equal error rate (EER) of 0.5% - 6% was achieved for 45 - 60s average training time. Our CWT/DLDA based technique outperformed all other dimensionality reduction techniques and previous work.
Introduction
While traditional biometrics like fingerprints and facial recognition are widely deployed, they remain vulnerable to spoofing. Medical biometrics, such as Photoplethysmograph (PPG), offer inherent "liveness" detection and are easily collected via standard wearable sensors. However, the PPG signal is highly dynamic, changing significantly based on heart rate, emotional state, and physical activity. Most existing research relies on "single-session" data where subjects are at rest, failing to account for real-world variability. This paper addresses this gap by proposing a robust, non-fiducial authentication system that maintains performance across physical exercise, emotional stress, and multi-week time-lapses.
Methodology
To ensure robustness against signal distortion, the authors employ a non-fiducial, time-frequency approach. Unlike fiducial methods that rely on detecting specific landmarks like the dicrotic notch—which can disappear during high heart rates—this approach treats the pulse as a holistic waveform.
The system pipeline includes:
- Pre-processing: A Butterworth band-pass filter (0.5-5 Hz) removes noise, followed by "False Peak Removal" to discard physiologically impossible segments.
- Feature Extraction (CWT): The Continuous Wavelet Transform (using an 'Analytic Morse' wavelet) captures the time-varying frequency content unique to an individual’s cardiovascular signature.
- Dimensionality Reduction (DLDA): Direct Linear Discriminant Analysis is used to select features that maximize inter-individual differences while minimizing intra-individual variation, effectively addressing the "small sample size" problem.
- Matching: Authentication is finalized using Pearson’s Distance to compare test templates against the enrolled gallery.
Experimental Evaluation
The algorithm was rigorously tested across three distinct datasets:
- Capnobase: Baseline single-session evaluation (42 subjects).
- DEAP: Evaluation across various emotional states (32 subjects).
- BioSec.Lab PPG Dataset: Evaluation of physical stress (post-exercise) and time-lapse effects (2-week interval) (41 subjects).
Notably, the system requires only 45–60 seconds of training data, making it highly practical for consumer applications.
Results and Discussion
The CWT/DLDA approach consistently outperformed standard dimensionality reduction techniques such as PCA, LDA, and Kernel-based methods across all tested scenarios.
Key results include:
- Baseline Performance: An EER of 0.46% was achieved on the Capnobase dataset.
- Emotional Robustness: On the DEAP dataset, the system maintained a 2.11% EER, significantly outperforming previous benchmarks.
- Stress and Time-Lapse: Under physical exercise, the EER rose to ~5%, and with a two-week time-lapse, it reached ~5.88%. While physical activity remains a challenge due to the homogenization of heart pulse shapes, these results represent a significant advancement in PPG biometric viability.
Conclusion
This research demonstrates that a non-fiducial CWT/DLDA framework can provide reliable authentication even when the user's physiological state changes. While physical stress and long-term stability remain areas for improvement, the achieved EERs suggest that PPG is a viable candidate for both convenience-based and continuous authentication in wearable devices. Future work will explore advanced feature selection to further isolate identity-specific signal components.
Summary updated